Esophageal Pressure Topography Criteria Indicative of Incomplete Bolus Clearance: A Study Using High-Resolution Impedance Manometry

被引:78
作者
Bulsiewicz, William J.
Kahrilas, Peter J.
Kwiatek, Monika A.
Ghosh, Sudip K.
Meek, Albert [2 ]
Pandolfino, John E. [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Med, Div Gastroenterol, Chicago, IL 60611 USA
[2] Med Measurement Syst, Enschede, Netherlands
关键词
MULTICHANNEL INTRALUMINAL IMPEDANCE; HIATAL-HERNIA; MOTILITY; CLASSIFICATION; TRANSPORT; ABNORMALITIES; ACID;
D O I
10.1038/ajg.2009.467
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVES: This study used high-resolution impedance manometry (HRIM) to determine pressure topography thresholds of peristaltic integrity predictive of incomplete esophageal bolus clearance. METHODS: A total of 16 normal controls and 8 patients with dysphagia were studied using a solid-state HRIM assembly incorporating 36 manometric sensors and 12 impedance segments. Each of the 10 saline swallows in each study was dichotomously scored as either complete or incomplete bolus clearance by impedance criteria, and peristaltic integrity was evaluated using pressure topography isobaric contours ranging from 10 to 30 mm Hg in 5-mm Hg increments. Each isobaric contour plot was characterized by the location and length of breaks in the isobaric contour. RESULTS: All subjects had normal esophagogastric junction (EGJ) relaxation and none met the pressure topography criteria of hiatus hernia. In all, 70 (29%) of the 240 individual swallows had incomplete bolus clearance. In every case, an intact >= 20 mm Hg isobaric contour was associated with complete bolus clearance. The largest defect in the 20 and 30 mm Hg isobaric contours associated with complete bolus clearance measured 1.7 and 3.0 cm, respectively, in length, whereas the smallest defect predictive of incomplete bolus clearance measured 2.1 and 3.2 cm, respectively. CONCLUSIONS: In individuals with normal EGJ relaxation and morphology, peristaltic contractions with breaks < 2 cm in the 20 mm Hg isobaric contour or < 3 cm in the 30 mm Hg isobaric contour are associated with complete bolus clearance, and longer breaks predict incomplete bolus clearance.
引用
收藏
页码:2721 / 2728
页数:8
相关论文
共 50 条
  • [41] Baseline Impedance Measured During High-resolution Esophageal Impedance Manometry in Patients With Rumination Syndrome is as Abnormal as in Patients With GERD
    Halland, Magnus
    Ravi, Karthik
    Nelson, Holly A.
    Katzka, David A.
    Talley, Nicholas J.
    Crowell, Michael D.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2020, 54 (01) : 28 - 34
  • [42] High-resolution esophageal manometry in systemic sclerosis in the indian population: An observational study
    Kartik, S.
    Kumar, Dharmendra
    Sikri, Gaurav
    Dey, Deepanjan
    Srinivasa, A. B.
    Kumar, Binit
    INDIAN JOURNAL OF RHEUMATOLOGY, 2020, 15 (02) : 106 - 110
  • [43] Phenotypes and Clinical Context of Hypercontractility in High-Resolution Esophageal Pressure Topography (EPT)
    Roman, Sabine
    Pandolfino, John E.
    Chen, Joan
    Boris, Lubomyr
    Luger, Daniel
    Kahrilas, Peter J.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2012, 107 (01) : 37 - 45
  • [44] Personalized diagnosis of patients with gastroesophageal reflux disease using 24-hour pH-impedance testing and high-resolution esophageal manometry
    Maev, Igor V.
    Yurenev, Georgy L.
    Barkalova, Elena V.
    Ovsepian, Mariia A.
    Andreev, Dmitry N.
    Shaburov, Rafik I.
    TERAPEVTICHESKII ARKHIV, 2024, 96 (08) : 757 - 763
  • [45] New esophageal function testing (impedance, Bravo pH monitoring, and high-resolution manometry): Clinical relevance
    Wilson J.A.
    Vela M.F.
    Current Gastroenterology Reports, 2008, 10 (3) : 222 - 230
  • [46] High-resolution impedance manometry parameters in the evaluation of esophageal function of non-obstructive dysphagia patients
    Singendonk, Maartje J.
    Lin, Zhiyue
    Scheerens, Charlotte
    Tack, Jan
    Carlson, Dustin A.
    Omari, Taher, I
    Pandolfino, John E.
    Rommel, Nathalie
    NEUROGASTROENTEROLOGY AND MOTILITY, 2019, 31 (02)
  • [47] How a modified Nissen procedure works: a mechanistic study using intraoperative esophageal high-resolution manometry
    Bardini, Romeo
    Battaglia, Silvia
    Scarpa, Marco
    Savarino, Edoardo
    LANGENBECKS ARCHIVES OF SURGERY, 2022, 407 (01) : 123 - 129
  • [48] Effect of Different Viscosities on Pharyngeal Pressure During Swallowing: A Study Using High-Resolution Manometry
    Park, Donghwi
    Shin, Cheol Min
    Ryu, Ju Seok
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2017, 98 (03): : 487 - 494
  • [49] Normal esophageal pressure topography metrics for data derived from the Sandhill-Unisensor high-resolution manometry assembly in supine and sitting positions
    do Carmo, G. C.
    Jafari, J.
    Sifrim, D.
    de Oliveira, R. B.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2015, 27 (02) : 285 - 292
  • [50] Prediction of Esophageal Retention: A Study Comparing High-Resolution Manometry and Functional Luminal Imaging Probe Panometry
    Carlson, Dustin A.
    Baumann, Alexandra J.
    Prescott, Jacqueline E.
    Schauer, Jacob M.
    Krause, Amanda
    Donnan, Erica N.
    Kou, Wenjun
    Kahrilas, Peter J.
    Pandolfino, John E.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2021, 116 (10) : 2032 - 2041