Esophageal Pressure Topography Criteria Indicative of Incomplete Bolus Clearance: A Study Using High-Resolution Impedance Manometry

被引:78
作者
Bulsiewicz, William J.
Kahrilas, Peter J.
Kwiatek, Monika A.
Ghosh, Sudip K.
Meek, Albert [2 ]
Pandolfino, John E. [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Med, Div Gastroenterol, Chicago, IL 60611 USA
[2] Med Measurement Syst, Enschede, Netherlands
关键词
MULTICHANNEL INTRALUMINAL IMPEDANCE; HIATAL-HERNIA; MOTILITY; CLASSIFICATION; TRANSPORT; ABNORMALITIES; ACID;
D O I
10.1038/ajg.2009.467
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVES: This study used high-resolution impedance manometry (HRIM) to determine pressure topography thresholds of peristaltic integrity predictive of incomplete esophageal bolus clearance. METHODS: A total of 16 normal controls and 8 patients with dysphagia were studied using a solid-state HRIM assembly incorporating 36 manometric sensors and 12 impedance segments. Each of the 10 saline swallows in each study was dichotomously scored as either complete or incomplete bolus clearance by impedance criteria, and peristaltic integrity was evaluated using pressure topography isobaric contours ranging from 10 to 30 mm Hg in 5-mm Hg increments. Each isobaric contour plot was characterized by the location and length of breaks in the isobaric contour. RESULTS: All subjects had normal esophagogastric junction (EGJ) relaxation and none met the pressure topography criteria of hiatus hernia. In all, 70 (29%) of the 240 individual swallows had incomplete bolus clearance. In every case, an intact >= 20 mm Hg isobaric contour was associated with complete bolus clearance. The largest defect in the 20 and 30 mm Hg isobaric contours associated with complete bolus clearance measured 1.7 and 3.0 cm, respectively, in length, whereas the smallest defect predictive of incomplete bolus clearance measured 2.1 and 3.2 cm, respectively. CONCLUSIONS: In individuals with normal EGJ relaxation and morphology, peristaltic contractions with breaks < 2 cm in the 20 mm Hg isobaric contour or < 3 cm in the 30 mm Hg isobaric contour are associated with complete bolus clearance, and longer breaks predict incomplete bolus clearance.
引用
收藏
页码:2721 / 2728
页数:8
相关论文
共 50 条
  • [11] Roles of High-resolution Manometry in Predicting Incomplete Bolus Transit in Patients With Dysphagia
    Shi, Zhaohong
    Guo, Jie
    Clarke, John
    Jin, Haifeng
    Wang, Xinjun
    Zhang, Nina
    Stein, Ellen
    Dhalla, Sameer
    Pasricha, Pankaj J.
    Chen, Jiande D. Z.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2018, 52 (09) : E73 - E81
  • [12] Bolus transit of upper esophageal sphincter on high-resolution impedance manometry study correlate with the laryngopharyngeal reflux symptoms
    Wu, Jia-Feng
    Hsu, Wei-Chung
    Tsai, I-Jung
    Tong, Tzu-Wei
    Lin, Yu-Cheng
    Yang, Chia-Hsiang
    Tseng, Ping-Huei
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [13] Assessment of Esophageal High-Resolution Impedance Manometry in Patients with Nonobstructive Dysphagia
    Liu, Zhaoyu
    Liao, Jiazhi
    Tian, Dean
    Liu, Mei
    Dan, Zili
    Yu, Qin
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2018, 2018
  • [14] Characterization of Esophageal Motility in Children With Operated Esophageal Atresia Using High-resolution Impedance Manometry and Pressure Flow Analysis
    Courbette, Olivier
    Omari, Taher
    Aspirot, Ann
    Faure, Christophe
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2020, 71 (03) : 304 - 309
  • [15] High-resolution Esophageal Manometry: Using Technical Advances for Clinical Advantages
    Ayazi, Shahin
    Crookes, Peter F.
    JOURNAL OF GASTROINTESTINAL SURGERY, 2010, 14 : 24 - 32
  • [16] Clinical applications of esophageal impedance monitoring and high-resolution manometry
    Boudewijn F. Kessing
    André J. P. M. Smout
    Albert J. Bredenoord
    Current Gastroenterology Reports, 2012, 14 (3) : 197 - 205
  • [17] High-resolution manometry and impedance-pH/manometry: novel techniques for the advancement of knowledge on esophageal function and their clinical role
    Ciriza-de-los-Rios, C.
    Canga-Rodriguez-Vacarcel, F.
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2009, 101 (12) : 861 - 869
  • [18] Assessing Bolus Retention in Achalasia Using High-Resolution Manometry With Impedance: A Comparator Study With Timed Barium Esophagram
    Cho, Yu K.
    Lipowska, Anna M.
    Nicodeme, Frederic
    Teitelbaum, Ezra N.
    Hungness, Eric S.
    Johnston, Elyse R.
    Gawron, Andrew
    Kahrilas, Peter J.
    Pandolfino, John E.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 (06) : 829 - 835
  • [19] Distal Esophageal Spasm in High-Resolution Esophageal Pressure Topography: Defining Clinical Phenotypes
    Pandolfino, John E.
    Roman, Sabine
    Carlson, Dustin
    Luger, Daniel
    Bidari, Kiran
    Boris, Lubomyr
    Kwiatek, Monika A.
    Kahrilas, Peter J.
    GASTROENTEROLOGY, 2011, 141 (02) : 469 - 475
  • [20] Esophageal dysmotility associated with systemic sclerosis: a high-resolution manometry study
    Roman, S.
    Hot, A.
    Fabien, N.
    Cordier, J. -F.
    Miossec, P.
    Ninet, J.
    Mion, F.
    DISEASES OF THE ESOPHAGUS, 2011, 24 (05) : 299 - 304