Esophageal Pressure Topography Criteria Indicative of Incomplete Bolus Clearance: A Study Using High-Resolution Impedance Manometry

被引:78
作者
Bulsiewicz, William J.
Kahrilas, Peter J.
Kwiatek, Monika A.
Ghosh, Sudip K.
Meek, Albert [2 ]
Pandolfino, John E. [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Med, Div Gastroenterol, Chicago, IL 60611 USA
[2] Med Measurement Syst, Enschede, Netherlands
关键词
MULTICHANNEL INTRALUMINAL IMPEDANCE; HIATAL-HERNIA; MOTILITY; CLASSIFICATION; TRANSPORT; ABNORMALITIES; ACID;
D O I
10.1038/ajg.2009.467
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVES: This study used high-resolution impedance manometry (HRIM) to determine pressure topography thresholds of peristaltic integrity predictive of incomplete esophageal bolus clearance. METHODS: A total of 16 normal controls and 8 patients with dysphagia were studied using a solid-state HRIM assembly incorporating 36 manometric sensors and 12 impedance segments. Each of the 10 saline swallows in each study was dichotomously scored as either complete or incomplete bolus clearance by impedance criteria, and peristaltic integrity was evaluated using pressure topography isobaric contours ranging from 10 to 30 mm Hg in 5-mm Hg increments. Each isobaric contour plot was characterized by the location and length of breaks in the isobaric contour. RESULTS: All subjects had normal esophagogastric junction (EGJ) relaxation and none met the pressure topography criteria of hiatus hernia. In all, 70 (29%) of the 240 individual swallows had incomplete bolus clearance. In every case, an intact >= 20 mm Hg isobaric contour was associated with complete bolus clearance. The largest defect in the 20 and 30 mm Hg isobaric contours associated with complete bolus clearance measured 1.7 and 3.0 cm, respectively, in length, whereas the smallest defect predictive of incomplete bolus clearance measured 2.1 and 3.2 cm, respectively. CONCLUSIONS: In individuals with normal EGJ relaxation and morphology, peristaltic contractions with breaks < 2 cm in the 20 mm Hg isobaric contour or < 3 cm in the 30 mm Hg isobaric contour are associated with complete bolus clearance, and longer breaks predict incomplete bolus clearance.
引用
收藏
页码:2721 / 2728
页数:8
相关论文
共 50 条
  • [1] High-resolution Impedance Manometry Criteria in the Sitting Position Indicative of Incomplete Bolus Clearance
    Park, Eui Ju
    Lee, Joon Seong
    Lee, Tae Hee
    Bok, Gene Hyun
    Hong, Su Jin
    Kim, Hyun Gun
    Jeon, Seong Ran
    Kim, Jin-Oh
    JOURNAL OF NEUROGASTROENTEROLOGY AND MOTILITY, 2014, 20 (04) : 491 - 496
  • [2] Effects of Posture and Swallow Volume on Esophageal Motility Morphology and Probability of Bolus Clearance A Study Using High-Resolution Impedance Manometry
    Pu, Liping
    Chavalitdhamrong, Disaya
    Summerlee, Robert J.
    Zhang, Qing
    GASTROENTEROLOGY NURSING, 2020, 43 (06) : 440 - 447
  • [3] Impaired bolus clearance in asymptomatic older adults during high-resolution impedance manometry
    Cock, C.
    Besanko, L.
    Kritas, S.
    Burgstad, C. M.
    Thompson, A.
    Heddle, R.
    Fraser, R. J. L.
    Omari, T. I.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2016, 28 (12) : 1890 - 1901
  • [4] High-Resolution Manometry: An Atlas of Esophageal Motility Disorders and Findings of GERD Using Esophageal Pressure Topography
    Pandolfino, John E.
    Roman, Sabine
    THORACIC SURGERY CLINICS, 2011, 21 (04) : 465 - +
  • [5] Pediatric rumination subtypes: A study using high-resolution esophageal manometry with impedance
    Rosen, R.
    Rodriguez, L.
    Nurko, S.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2017, 29 (05)
  • [6] High-Resolution Manometry and Esophageal Pressure Topography Filling the Gaps of Convention Manometry
    Carlson, Dustin A.
    Pandolfino, John E.
    GASTROENTEROLOGY CLINICS OF NORTH AMERICA, 2013, 42 (01) : 1 - +
  • [7] Parameters for quantifying bolus retention with high-resolution impedance manometry
    Lin, Z.
    Nicodeme, F.
    Lin, C. -Y.
    Mogni, B.
    Friesen, L.
    Kahrilas, P. J.
    Pandolfino, J. E.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2014, 26 (07) : 929 - 936
  • [8] The four phases of esophageal bolus transit defined by high-resolution impedance manometry and fluoroscopy
    Lin, Zhiyue
    Yim, Brandon
    Gawron, Andrew
    Imam, Hala
    Kahrilas, Peter J.
    Pandolfino, John E.
    AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 2014, 307 (04): : G437 - G444
  • [9] Systematic analysis of esophageal pressure topography in high-resolution manometry of 68 normal volunteers
    Niebisch, S.
    Wilshire, C. L.
    Peters, J. H.
    DISEASES OF THE ESOPHAGUS, 2013, 26 (07) : 651 - 660
  • [10] Impaired bolus clearance in combined high-resolution esophageal manometry and impedance measurement helps to differentiate between esophagogastric junction outflow obstruction and achalasia
    Zizer, Eugen
    Seufferlein, Thomas
    Hanle, Mark Martin
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2017, 55 (02): : 129 - 135