Automatic Selection of Webcam Photoplethysmographic Pixels Based on Lightness Criteria

被引:24
作者
Bousefsaf, Frederic [1 ]
Maaoui, Choubeila [1 ]
Pruski, Alain [1 ]
机构
[1] Univ Lorraine, LCOMS, Batiment ISEA Inst Super Elect & Automat, F-57070 Metz Technopole, France
关键词
Remote photoplethysmography; Pulse rate; Webcam; Region of interest; NONCONTACT HEART-RATE; REMOTE DETECTION; STRESS;
D O I
10.1007/s40846-017-0229-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose, in this study, an original method that was developed to remotely measure the instantaneous pulse rate using photoplethysmographic signals that were recorded from a low-cost webcam. The method is based on a prior selection of pixels of interest using a custom segmentation that used the face lightness distribution to define different sub-regions. The most relevant sub-regions are automatically selected and combined by evaluating their respective signal to noise ratio. Performances of the proposed technique were evaluated using an approved contact sensor on a set of seven healthy subjects. Different experiments while reading, with motion or while performing common tasks on a computer were conducted in the laboratory. The proposed segmentation technique was compared with other benchmark methods that were already introduced in the scientific literature. The results exhibit high degrees of correlation and low pulse rate absolute errors, demonstrating that the segmentation we propose in this study outperform available region-of-interest selection methods.
引用
收藏
页码:374 / 385
页数:12
相关论文
共 26 条
[1]   Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit - A pilot study [J].
Aarts, Lonneke A. M. ;
Jeanne, Vincent ;
Cleary, John P. ;
Lieber, C. ;
Nelson, J. Stuart ;
Oetomo, Sidarto Bambang ;
Verkruysse, Wim .
EARLY HUMAN DEVELOPMENT, 2013, 89 (12) :943-948
[2]   Remote detection of mental workload changes using cardiac parameters assessed with a low-cost webcam [J].
Bousefsaf, Frederic ;
Maaoui, Choubeila ;
Pruski, Alain .
COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 53 :154-163
[3]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[4]   Motion-Resistant Remote Imaging Photoplethysmography Based on the Optical Properties of Skin [J].
Feng, Litong ;
Po, Lai-Man ;
Xu, Xuyuan ;
Li, Yuming ;
Ma, Ruiyi .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2015, 25 (05) :879-891
[5]   Detecting stress during real-world driving tasks using physiological sensors [J].
Healey, JA ;
Picard, RW .
IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2005, 6 (02) :156-166
[6]  
Hernandez J, 2011, LECT NOTES COMPUT SC, V6974, P125, DOI 10.1007/978-3-642-24600-5_16
[7]   Signal recovery in imaging photoplethysmography [J].
Holton, Benjamin D. ;
Mannapperuma, Kavan ;
Lesniewski, Peter J. ;
Thomas, John C. .
PHYSIOLOGICAL MEASUREMENT, 2013, 34 (11) :1499-1511
[8]   Real-time detection of workload changes using heart rate variability [J].
Hoover, Adam ;
Singh, Anirud ;
Fishel-Brown, Stephanie ;
Muth, Eric .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2012, 7 (04) :333-341
[9]   Noncontact simultaneous dual wavelength photoplethysmography: A further step toward noncontact pulse oximetry [J].
Humphreys, Kenneth ;
Ward, Tomas ;
Markham, Charles .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (04)
[10]   Non-contact detection of oxygen saturation based on visible light imaging device using ambient light [J].
Kong, Lingqin ;
Zhao, Yuejin ;
Dong, Liquan ;
Jian, Yiyun ;
Jin, Xiaoli ;
Li, Bing ;
Feng, Yun ;
Liu, Ming ;
Liu, Xiaohua ;
Wu, Hong .
OPTICS EXPRESS, 2013, 21 (15) :17464-17471