Multifunctional Dendrimer-Templated Antibody Presentation on Biosensor Surfaces for Improved Biomarker Detection

被引:48
作者
Han, Hye Jung [1 ,2 ]
Kannan, Rangaramanujam M. [1 ,2 ]
Wang, Sunxi [1 ]
Mao, Guangzhao [1 ]
Kusanovic, Juan Pedro [3 ]
Romero, Roberto [2 ]
机构
[1] Wayne State Univ, Dept Chem Engn & Mat Sci, Detroit, MI 48202 USA
[2] Eunice Kennedy Shriver Natl Inst Child Hlth & Hum, NICHD, NIH, DHHS, Detroit, MI 48201 USA
[3] Wayne State Univ, Perinatol Res Branch, NICHD, NIH,DHHS,Dept Obstet & Gynecol,Hutzel Womens Hosp, Detroit, MI 48201 USA
关键词
SELF-ASSEMBLED MONOLAYERS; ATOMIC-FORCE MICROSCOPY; INFLAMMATORY RESPONSE SYNDROME; PROTEIN-LIGAND INTERACTIONS; LINKED-IMMUNOSORBENT-ASSAY; AFFINITY-SENSING SURFACE; POLY(ETHYLENE GLYCOL); SOLID SUPPORTS; INTRAAMNIOTIC INFECTION; STICKING PROBABILITIES;
D O I
10.1002/adfm.200901293
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Dendrimers, with their well-defined globular shape and high density of functional groups, are ideal nanoscale materials for templating sensor surfaces. This work exploits dendrimers as a versatile platform for capturing biomarkers with improved sensitivity and specificity. The synthesis, characterization, fabrication, and functional validation of the dendrimer-based assay platform are described. Bifunctional hydroxyl/thiol-functionalized G4-polyamidoamine (PAMAM) dendrimer is synthesized and immobilized on the polyethylene-glycol (PEG)-functionalized assay plate by coupling PEG-maleimide and dendrimer thiol groups. Simultaneously, part of the dendrimer thiol groups are converted to hydrazide functionalities. The resulting dendrimer-modified surface is coupled to the capture antibody in the Fc region of the oxidized antibody. This preserves the orientation flexibility of the antigen binding region (Fv) of the antibody. To validate the approach, the fabricated plates are further used as a solid phase for developing a sandwich-type enzyme-linked immunosorbent assay (ELISA) to detect IL-6 and IL-1 beta, important biomarkers for early stages of chorioamnionitis. The dendrimer-modified plate provides assays with significantly enhanced sensitivity, lower nonspecific adsorption, and a detection limit of 0.13 pg mL(-1) for IL-6 luminol detection and 1.15 pg mL(-1) for IL-1 beta TMB detection, which are significantly better than those for the traditional ELISA. The assays were validated in human serum samples from a normal (nonpregnant) woman and pregnant women with pyelonephritis. The specificity and the improved sensitivity of the dendrimer-based capture strategy could have significant implications for the detection of a wide range of cytokines and biomarkers since the capture strategy could be applied to multiplex microbead assays, conductometric immunosensors, and field-effect biosensors.
引用
收藏
页码:409 / 421
页数:13
相关论文
共 92 条
[1]   Atomic force microscopy studies of generation 4 poly(amidoamine) (PAMAM) dendrimers on functionalized surfaces [J].
Abdelhady, HG ;
Allen, S ;
Davies, MC ;
Roberts, CJ ;
Tendler, SJB ;
Williams, PM .
SURFACE SCIENCE, 2004, 558 (1-3) :99-110
[2]   THE INFLUENCE OF PERIODATE-OXIDATION ON MONOCLONAL-ANTIBODY AVIDITY AND IMMUNOREACTIVITY [J].
ABRAHAM, R ;
MOLLER, D ;
GABEL, D ;
SENTER, P ;
HELLSTROM, I ;
HELLSTROM, KE .
JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 144 (01) :77-86
[3]   Specific capture of target proteins by oriented antibodies bound to tyrosinase-immobilized Protein A on a polyallylamine affinity membrane surface [J].
Ahmed, Sufi R. ;
Lutes, Andrew T. ;
Barbari, Timothy A. .
JOURNAL OF MEMBRANE SCIENCE, 2006, 282 (1-2) :311-321
[4]   Carboxyl-terminated dendrimer-coated bioactive interface for protein microarray: High-sensitivity detection of antigen in complex biological samples [J].
Ajikumar, Parayil Kumaran ;
Kiat, Jin ;
Tang, Yew Chung ;
Lee, Jim Yang ;
Stephanopoulos, Gregory ;
Too, Heng-Phon .
LANGMUIR, 2007, 23 (10) :5670-5677
[5]   DNA microarrays with PAMAM dendritic linker systems -: art. no. e10 [J].
Benters, R ;
Niemeyer, CM ;
Drutschmann, D ;
Blohm, D ;
Wöhrle, D .
NUCLEIC ACIDS RESEARCH, 2002, 30 (02) :10
[6]  
Benters R, 2001, CHEMBIOCHEM, V2, P686, DOI 10.1002/1439-7633(20010903)2:9<686::AID-CBIC686>3.0.CO
[7]  
2-S
[8]   An immunological interleukin-6 capacitive biosensor using perturbation with a potentiostatic step [J].
Berggren, C ;
Bjarnason, B ;
Johansson, G .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (10) :1061-1068
[9]   STERIC EXCLUSION IS THE PRINCIPAL SOURCE OF THE PREFERENTIAL HYDRATION OF PROTEINS IN THE PRESENCE OF POLYETHYLENE GLYCOLS [J].
BHAT, R ;
TIMASHEFF, SN .
PROTEIN SCIENCE, 1992, 1 (09) :1133-1143
[10]   SELECTIVE REDUCTION OF DISULFIDES BY TRIS(2-CARBOXYETHYL)PHOSPHINE [J].
BURNS, JA ;
BUTLER, JC ;
MORAN, J ;
WHITESIDES, GM .
JOURNAL OF ORGANIC CHEMISTRY, 1991, 56 (08) :2648-2650