Influence of a brushing working motion on the fatigue life of NiTi rotary instruments

被引:37
作者
Plotino, G.
Grande, N. M.
Sorci, E.
Malagnino, V. A.
Somma, F.
机构
[1] Univ Cattolica Sacro Cuore, Dept Endodont, I-00168 Rome, Italy
[2] Univ G DAnnunzio, Dept Endodont, Chieti, Italy
关键词
brushing action; cyclic fatigue; Mtwo NiTi rotary instruments;
D O I
10.1111/j.1365-2591.2006.01179.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: To evaluate the cyclic fatigue resistance of Mtwo NiTi rotary instruments when used with a brushing or no-brushing action in oval root canals. Methodology: Cyclic fatigue testing of instruments was performed in tapered artificial canals with a 5 mm radius of curvature and an angle of curvature of 60 degrees. Twenty Mtwo instruments for each size were selected and divided into two groups: group A = 10 instruments used with a no-brushing motion (control group); group B = 10 instruments used with a brushing-milling action. Each Mtwo instrument was used for cleaning and shaping 10 oval root canals. In all 80 instruments were rotated until fracture occurred and the number of cycles to failure (NCF) recorded. Data were analysed by one-way ANOVA, Tukey HSD test and independent sample t-test to determine any statistical difference; the significance was determined at the 95% confidence level. Results: No statistically significant reduction of NCF between instruments used with a no-brushing motion (group A) and instruments used with a brushing motion (group B) were apparent except for size 25, 0.06 taper. Mtwo size 10, 0.04 taper, size 15, 0.05 taper, size 20, 0.06 taper, size 25, 0.06 taper instruments had a decrease in life span of 1%, 0.5%, 8% and 19%, respectively. Conclusins: Fatigue life of instruments of larger size could be reduced by using them with a lateral brushing or pressing movement. However, each file was successfully operated without intracanal failure, demonstrating that Mtwo rotary instruments can be used safely in a brushing action in simulated clinical conditions up to 10 times in oval canals.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 44 条
[1]   The 'Lightspeed' preparation technique evaluated by Swiss clinicians after attending continuing education courses [J].
Barbakow, F ;
Lutz, F .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :46-50
[2]  
Barbizam JVB, 2002, J ENDODONT, V28, P365
[3]   A study on the thickness of radicular dentine and cementum in anterior and premolar teeth [J].
Bellucci, C ;
Perrini, N .
INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (07) :594-606
[4]  
Bergmans L, 2001, AM J DENT, V14, P324
[5]  
Clauder Thomas, 2004, Dent Clin North Am, V48, P87, DOI 10.1016/j.cden.2003.10.006
[6]  
de Melo MCC, 2002, J ENDODONT, V28, P765
[7]   Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical use [J].
Fife, D ;
Gambarini, G ;
Britto, LR .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2004, 97 (02) :251-256
[8]   SEM evaluation of canal wall dentine following use of Mtwo and ProTaper NiTi rotary instruments [J].
Foschi, F ;
Nucci, C ;
Montebugnoli, L ;
Marchionni, S ;
Breschi, L ;
Malagnino, VA ;
Prati, C .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (12) :832-839
[9]  
Friedman S., 2002, ENDODONTIC TOPICS, V2002, P59, DOI [10.1034/j.1601-1546.2002.20105.x, DOI 10.1034/J.1601-1546.2002.20105.X]
[10]   Cyclic fatigue of Profile rotary instruments after prolonged clinical use [J].
Gambarini, G .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (05) :386-389