Retention of fluorinated chiral selectors in biphasic fluorinated solvent systems and its application to the separation of enantiomers by countercurrent chromatography

被引:29
作者
Maria Perez, Anna [1 ,2 ]
Minguillon, Cristina [1 ,2 ]
机构
[1] PCB, IRB Barcelona, E-08028 Barcelona, Spain
[2] Univ Barcelona, Fac Pharm, Quim Farmaceut Lab, E-08028 Barcelona, Spain
关键词
Countercurrent chromatography (CCC); Enantiomer separation; Chiral selector; Ethoxynonafluorobutane; HFE-7200; ENFB; Fluorinated chiral selector; CENTRIFUGAL PARTITION CHROMATOGRAPHY; PERFORMANCE LIQUID-CHROMATOGRAPHY; DERIVATIVES; ETHOXYNONAFLUOROBUTANE;
D O I
10.1016/j.chroma.2009.09.071
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ethoxynonafluorobutane (ENFB) has been used as a component of new biphasic solvent mixtures. The suitability of several mixtures as solvent systems in countercurrent chromatography was tested. The applicability of the ENFB/2-PrOH/H2O mixture to the separation of enantiomers, in combination with a fluorinated chiral selector (CS), was evaluated. N-Perfluoroundecanoyl-L-proline-3,5-dimethylanilide (2). analogous to the previously used N-dodecyl-L-proline-3,5-dimethylanilide (1). was synthesized for this purpose. The capacity of the new solvent system to retain the fluorinated CS in the fluorinated phase used as stationary was examined. Chiral selector I was applied in analogous conditions for comparative purposes. Additionally, MTBE/phosphate buffer solvent system was also used with the two CSs. The ENFB/2-PrOH/H2O (25:35:40) mixture was found to be adequate in the enantioseparation of DNB-Leu and DNB-Leu-tBu. Enantioselectivity was maintained in the fluorinated solvent system without compromising eluting time. The complete separation of DNB-Leu-tBu was achieved and no leaks of CS to the mobile phase were detected. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1094 / 1100
页数:7
相关论文
共 26 条
[1]  
Berthod A., 2002, COUNTERCURRENT CHROM, V38
[2]   COUNTERCURRENT CHROMATOGRAPHY IN ANALYTICAL CHEMISTRY (IUPAC Technical Report) [J].
Berthod, Alain ;
Maryutina, Tatyana ;
Spivakov, Boris ;
Shpigun, Oleg ;
Sutherland, Ian A. .
PURE AND APPLIED CHEMISTRY, 2009, 81 (02) :355-387
[3]  
Conway WD., 1990, Countercurrent Chromatography: Apparatus, Theory and Applications
[4]  
Curran DP, 1998, ANGEW CHEM INT EDIT, V37, P1175, DOI 10.1002/(SICI)1521-3773(19980518)37:9<1174::AID-ANIE1174>3.0.CO
[5]  
2-P
[6]   Development of fluorinated, monolithic columns for improved chromatographic separations of fluorous-tagged analytes [J].
Daley, Adam B. ;
Oleschuk, Richard D. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (05) :772-780
[7]   Enantiomer separation by counter-current chromatography -: Optimisation and drawbacks in the use of L-proline derivatives as chiral selectors [J].
Delgado, B ;
Pérez, E ;
Santano, MC ;
Minguillón, C .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1092 (01) :36-42
[8]   Evaluation of ethoxynonafluorobutane as a safe and environmentally friendly solvent for chiral normal-phase LC-atmospheric pressure chemical ionization/electrospray ionization-mass spectrometry [J].
Ding, J ;
Desai, M ;
Armstrong, DW .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1076 (1-2) :34-43
[9]   Morpholine-based immonium and halogenoamidinium salts as coupling reagents in peptide synthesis [J].
El-Faham, Ayman ;
Albericio, Fernando .
JOURNAL OF ORGANIC CHEMISTRY, 2008, 73 (07) :2731-2737
[10]  
Foucault A. P., 1995, CHROMATOGRAPHIC SCI, V68