Initial experience with Duplex scan combined with contrast-enhanced ultrasound for follow-up of endovascular abdominal aortic aneurysm repair

被引:1
作者
Faustino, Carolina Brito [1 ]
Ventura, Carlos [1 ]
Cassino Portugal, Maria Fernanda [1 ]
Brunheroto, Andre [1 ]
Teivelis, Marcelo Passos [1 ]
Wolosker, Nelson [1 ,2 ]
机构
[1] Hosp Israelita Albert Einstein HIAE, Sao Paulo, SP, Brazil
[2] Univ Sao Paulo FMUSP, Fac Med, Sao Paulo, SP, Brazil
关键词
microbubbles; EVAR; endoleaks; ultrasound;
D O I
10.1590/1677-5449.200093
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Microbubble contrast enhanced ultrasound (CEUS) is an accurate diagnostic method for follow-up after endovascular abdominal aortic aneurysm repair (EVAR) that has been well-established in international studies. However, there are no Brazilian studies that focus on this follow-up method. Objectives: The objective of this study was to report initial experience with CEUS at a tertiary hospital, comparing the findings of CEUS with those of conventional Doppler ultrasound (DUS), with the aim of determining whether addition of contrast to the standard ultrasonographic control protocol resulted in different findings. Methods: From 2015 to 2017, 21 patients in follow-up after EVAR underwent DUS followed by CEUS. The findings of these examinations were analyzed in terms of identification of complications and their capacity to identify the origin of endoleaks. Results: There was evidence of complications in 10 of the 21 cases examined: seven patients exhibited endoleaks (33.3%); two patients exhibited stenosis of a branch of the endograft (9.52%); and one patient exhibited a dissection involving the external iliac artery (4.76%). In the 21 patients assessed, combined use of both methods identified 10 cases of post-EVAR complications. In six of the seven cases of endoleaks (85.71%), use of the methods in combination was capable of identifying the origin of endoleakage. DUS alone failed to identify endoleaks in two cases (28.5%) and identified doubtful findings in another two cases (28.5%), in which diagnostic definition was achieved after employing CEUS. Conclusions: CEUS is a technique that is easy to perform and provides additional support for follow-up of infrarenal EVAR.
引用
收藏
页数:9
相关论文
共 42 条
[1]   Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair [J].
Abraha, Iosief ;
Luchetta, Maria Laura ;
De Florio, Rita ;
Cozzolino, Francesco ;
Casazza, Giovanni ;
Duca, Piergiorgio ;
Parente, Basso ;
Orso, Massimiliano ;
Germani, Antonella ;
Eusebi, Paolo ;
Montedori, Alessandro .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (06)
[2]   Safety of Contrast in Stress Echocardiography in Stable Patients and in Patients With Suspected Acute Coronary Syndrome but Negative 12-Hour Troponin [J].
Anantharam, Brijesh ;
Chahal, Navtej ;
Chelliah, Rajesh ;
Ramzy, Ihab ;
Gani, Firoz ;
Senior, Roxy .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (01) :14-18
[3]  
Barnett SB, 2007, ULTRASOUND MED BIOL, V33, P173, DOI 10.1016/j.ultrasmedbio.2006.07.002
[4]   Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts [J].
Bendick, PJ ;
Bove, PG ;
Long, GW ;
Zelenock, GB ;
Brown, OW ;
Shanley, CJ .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (02) :381-385
[5]  
Cantador Alex Aparecido, 2016, Radiol Bras, V49, P229, DOI 10.1590/0100-3984.2014.0139
[6]   Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms:: Preliminary experience [J].
Carrafiello, Gianpaolo ;
Lagana, Domenico ;
Recaldini, Chiara ;
Mangini, Monica ;
Bertolotti, Elena ;
Caronno, Roberto ;
Tozzi, Matteo ;
Piffaretti, Gabriele ;
Genovese, Eugenio Annibale ;
Fugazzola, Carlo .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (06) :969-974
[7]   SVS practice guidelines for the care of patients with an abdominal aortic aneurysm: Executive summary [J].
Chaikof, Elliot L. ;
Brewster, David C. ;
Dalman, Ronald L. ;
Makaroun, Michel S. ;
Illig, Karl A. ;
Sicard, Gregorio A. ;
Timaran, Carlos H. ;
Upchurch, Gilbert R., Jr. ;
Veith, Frank J. .
JOURNAL OF VASCULAR SURGERY, 2009, 50 (04) :880-896
[8]   Improving the follow up after EVAR by using ultrasound image fusion of CEUS and MS-CT [J].
Clevert, D. A. ;
Helck, A. ;
D'Anastasi, M. ;
Guertler, V. ;
Sommer, W. H. ;
Meimarakis, G. ;
Weidenhagen, R. ;
Reiser, M. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 49 (1-4) :91-104
[9]   Ultrasound contrast agents:: properties, principles of action, tolerance, and artifacts [J].
Correas, JM ;
Bridal, L ;
Lesavre, A ;
Méjean, A ;
Claudon, M ;
Hélénon, O .
EUROPEAN RADIOLOGY, 2001, 11 (08) :1316-1328
[10]   Echocontrast-enhanced ultrasound of extracranial internal carotid artery high-grade stenosis and occlusion [J].
Droste, DW ;
Jürgens, R ;
Nabavi, DG ;
Schuierer, G ;
Weber, S ;
Ringelstein, EB .
STROKE, 1999, 30 (11) :2302-2306