Numerical analysis of stent expansion process in coronary artery stenosis with the use of non-compliant balloon

被引:26
作者
Bukala, Jakub [1 ]
Kwiatkowski, Piotr [2 ]
Malachowski, Jerzy [1 ]
机构
[1] Mil Univ Technol, Dept Mech & Appl Comp Sci, Ul Gen Sylwestra,Kaliskiego 2, PL-00908 Warsaw, Poland
[2] Cent Clin Hosp, Minist Interior, Clin Dept Intervent Cardiol, Warsaw, Poland
关键词
Stent; Angioplasty; Coronary; Fea; Numerical; Balloon; FINITE-ELEMENT-ANALYSIS; DEFORMATION; RESTENOSIS; SIMULATION; TISSUE; VESSEL; IMPACT;
D O I
10.1016/j.bbe.2015.10.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the paper the authors present an applied methodology, data and numerical results for numerical analysis of the stent crimping process and stent implantation in the coronary artery stenosis with the use of a non-compliant angioplasty balloon. The authors focused on the modeling methodology of balloon angioplasty with minimum possible simplification, i.e.: a full load path (compression and inflation in single analysis), 3D unsymmetrical geometry and discretization, highly nonlinear material models (hyperelasticity, plastic kinematic formulation, crushable foam) and sophisticated contact models (bodies with highly different stiffness). The use of a highly compressible crushable foam material model for an arterial plaque is considered as the most original part of the work. The presented results allow for better understanding of the mechanisms governing stent crimping and implementation. (C) 2015 Published by Elsevier Sp. z o.o. on behalf of Nalecz Institute of Biocybemetics and Biomedical Engineering.
引用
收藏
页码:145 / 156
页数:12
相关论文
共 29 条
  • [1] Numerical analysis of crimping and inflation process of balloon-expandable coronary stent using implicit solution
    Bukala, Jakub
    Kwiatkowski, Piotr
    Malachowski, Jerzy
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2017, 33 (12)
  • [2] Numerical Analysis for Non-Uniformity of Balloon-Expandable Stent Deployment Driven by Dogboning and Foreshortening
    Rahinj, Ganesh B.
    Chauhan, Harshit S.
    Sirivella, Martin L.
    Satyanarayana, Menta, V
    Ramanan, Laxminarayanan
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2022, 13 (02) : 247 - 264
  • [3] Stent Expansion After Additional Non-Compliant Balloon High-Pressure Inflation in Patients With Drug-Eluting Stent Underexpansion: An Intravascular Ultrasound Study
    Kim, Sang-Wook
    Lee, Wang Soo
    Mintz, Gary S.
    Hong, Young Joon
    Lee, Sung Yun
    Lee, Kwang Je
    Kim, Tae Ho
    Kim, Chee Jeong
    Ryu, Wang Seong
    Pichard, August D.
    Weissman, Neil J.
    CIRCULATION, 2010, 122 (21)
  • [4] Combination of Laser Atherectomy and Super High-pressure Non-compliant Balloon to Treat Stent Under-expansion in Cases of Failed Interventional Options
    Sasi, Viktor
    Szanto, Gyula
    Achim, Alexandru
    Ungi, Imre
    Varga, Albert
    Ruzsa, Zoltan
    INTERVENTIONAL CARDIOLOGY-REVIEWS RESEARCH RESOURCES, 2023, 18
  • [5] NUMERICAL ANALYSIS OF BALLOON EXPANDABLE STENT DEPLOYMENT INSIDE A PATIENT-SPECIFIC STENOTIC CORONARY ARTERY TO INVESTIGATE THE INSTANT MECHANICAL BEHAVIORS
    Xu, Chuangye
    Liu, Xiujian
    Pan, Lianqiang
    Wu, Guanghui
    Shu, Lixia
    He, Yuna
    Ma, Liping
    Lin, Changyan
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (07)
  • [6] HEMODYNAMIC ANALYSIS OF STENT EXPANSION RATIO FOR VERTEBRAL ARTERY OSTIAL STENOSIS INTERVENTION
    Niu, Jing
    Qiao, Ai-Ke
    Jiao, Li-Qun
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2013, 13 (04)
  • [7] Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation
    Muraoka, Yoshitaka
    Sonoda, Shinjo
    Tsuda, Yuki
    Tanaka, Seiya
    Okazaki, Masahiro
    Otsuji, Yutaka
    HEART AND VESSELS, 2011, 26 (06) : 565 - 571
  • [8] Numerical Analysis for Non-Uniformity of Balloon-Expandable Stent Deployment Driven by Dogboning and Foreshortening
    Ganesh B. Rahinj
    Harshit S. Chauhan
    Martin L. Sirivella
    Menta V. Satyanarayana
    Laxminarayanan Ramanan
    Cardiovascular Engineering and Technology, 2022, 13 : 247 - 264
  • [9] The use of coronary stent in hepatic artery stenosis after orthotopic liver transplantation
    Huang, Mingsheng
    Shan, Hong
    Jiang, Zaibo
    Li, Zhengran
    Zhu, Kangshun
    Guan, Shouhai
    Qian, Jiesheng
    Chen, Guihua
    Lu, Minqiang
    Yang, Yang
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 425 - 430
  • [10] Use of drug-eluting, balloon-expandable resolute onyx coronary stent as a novel treatment strategy for vertebral artery ostial stenosis: Case series
    Lim, Jaims
    Baig, Ammad A.
    Aguirre, Alexander O.
    Cappuzzo, Justin M.
    Vakharia, Kunal
    Rho, Kyungduk
    Waqas, Muhammad
    Monteiro, Andre
    Fretz, Thomas J.
    Levy, Elad, I
    Siddiqui, Adnan H.
    INTERVENTIONAL NEURORADIOLOGY, 2024, 30 (04) : 443 - 450