Double-exposure method for speckle-tracking x-ray phase-contrast microtomography

被引:3
|
作者
Yu, Fucheng [1 ,2 ,3 ]
Li, Ke [1 ,2 ,3 ]
Wang, Feixiang [2 ]
Zhang, Haipeng [1 ,2 ,3 ]
Ju, Xiaolu [1 ,2 ,3 ]
Xu, Mingwei [1 ,2 ,3 ]
Du, Guohao [2 ]
Deng, Biao [2 ]
Xie, Honglan [2 ]
Xiao, Tiqiao [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai Synchrotron Radiat Facil, Zhangjiang Lab, Shanghai 201204, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1063/5.0043053
中图分类号
O59 [应用物理学];
学科分类号
摘要
X-ray phase-contrast microtomography based on speckle tracking is an attractive method for non-destructive three-dimensional imaging owing to its simple setup and ability to yield absorption, refractive, and scattering images simultaneously. However, the edge-enhancement effect usually results in image artifacts or inaccurate phase retrieval, limiting the extensive application of this method in biomedical research and for low-Z materials. In this paper, a double-exposure method is introduced to solve this problem efficiently and accurately. Pure phase samples with various microstructures and densities and a biological sample with a distinct edge-enhancement effect were used to verify the effectiveness of the developed method. In an experiment performed using a polymer phantom with an evenly distributed density, 17 irregularly shaped particles with diameters ranging from 15 to 25 mu m were successfully reconstructed with the effective elimination of the edge-enhancement effect. The results obtained for a sample composed of different polymer materials demonstrated that, in contrast with the traditional speckle-tracking method, the present method is able to discriminate materials with similar x-ray attenuations. Finally, experiments were performed using a dehydrated fish, which entail typical edge enhancement and a complex microstructure; notably, it was verified that the fine structure of the fish, including its fins and intestines, was reconstructed completely using the proposed method, whereas the standard speckle-tracking method was ineffective. In conclusion, the developed double-exposure method can serve as an efficient and accurate technique for the x-ray phase-contrast microtomography of samples comprising low-Z materials and complicated microstructures.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Comparison of laboratory grating-based and speckle-tracking x-ray phase-contrast imaging
    Romell, J.
    Zhou, T.
    Zdora, M.
    Sala, S.
    Koch, F. J.
    Hertz, H. M.
    Burvall, A.
    X-RAY MICROSCOPY CONFERENCE 2016 (XRM 2016), 2017, 849
  • [2] The possibility of phase-contrast X-ray microtomography
    Momose, A
    Hirano, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 : 625 - 629
  • [3] X-ray phase-contrast microscopy and microtomography
    Mayo, SC
    Davis, TJ
    Gureyev, TE
    Miller, PR
    Paganin, D
    Pogany, A
    Stevenson, AW
    Wilkins, SW
    OPTICS EXPRESS, 2003, 11 (19): : 2289 - 2302
  • [4] Speckle-tracking X-ray phase-contrast imaging for samples with obvious edge-enhancement effect
    Wang, Feixiang
    Wang, Yudan
    Wei, Gongxiang
    Du, Guohao
    Xue, Yanling
    Hu, Tao
    Li, Ke
    Deng, Biao
    Xie, Honglan
    Xiao, Tiqiao
    APPLIED PHYSICS LETTERS, 2017, 111 (17)
  • [5] Design of X-ray interferometer for phase-contrast X-ray microtomography
    Momose, A
    Hirano, K
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 98 - 103
  • [6] Phase-contrast X-ray microtomography of mouse fetus
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    BIOLOGY OPEN, 2012, 1 (03): : 269 - 274
  • [7] Exploring experimental parameter choice for rapid speckle-tracking phase-contrast X-ray imaging with a paper analyzer
    Aloisio, Isobel A.
    Paganin, David M.
    Wright, Christopher A.
    Morgan, Kaye S.
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1279 - 1288
  • [8] Imaging renal structures by X-ray phase-contrast microtomography
    Wu, Jin
    Takeda, Tohoru
    Lwin, Thet Thet
    Momose, Atsushi
    Sunaguchi, Naoki
    Fukami, Tadanori
    Yuasa, Tetsuya
    Akatsuka, Takao
    KIDNEY INTERNATIONAL, 2009, 75 (09) : 945 - 951
  • [9] Review and experimental comparison of speckle-tracking algorithms for X-ray phase contrast imaging
    Celestre, Rafael
    Quenot, Laurene
    Ninham, Christopher
    Brun, Emmanuel
    Fardin, Luca
    JOURNAL OF SYNCHROTRON RADIATION, 2025, 32 : 180 - 199
  • [10] Speckle tracking phase-contrast computed tomography at an inverse Compton X-ray source
    Zandarco, Simon
    Guenther, Enedikt
    Riedel, Mirko
    Breitenhuber, Gregor
    Kirst, Miriam
    Achterhold, Klaus
    Pfeiffer, Franz
    Herzen, Julia
    OPTICS EXPRESS, 2024, 32 (16): : 28472 - 28488