SyntEyes: A Higher-Order Statistical Eye Model for Healthy Eyes

被引:26
作者
Rozema, Jos J. [1 ,2 ]
Rodriguez, Pablo [3 ,4 ]
Navarro, Rafael [3 ,4 ]
Tassignon, Marie-Jose [1 ,2 ]
机构
[1] Univ Antwerp Hosp, Dept Ophthalmol, Wilrijkstr 10, B-2650 Edegem, Belgium
[2] Univ Antwerp, Dept Med & Hlth Sci, Antwerp, Belgium
[3] CSIC, Inst Ciencia Mat Aragon, Zaragoza, Spain
[4] Univ Zaragoza, Fac Ciencias, E-50009 Zaragoza, Spain
关键词
statistical eye model; ocular biometry; SCHEMATIC EYE; OPTICAL ABERRATIONS; CRYSTALLINE LENS; CORNEAL; ACCOMMODATION; IMPLANTATION; MISALIGNMENT; OUTCOMES; QUALITY; IMAGE;
D O I
10.1167/iovs.15-18067
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Stochastic eye models are a method to generate random biometry data with the variability found in the general population for use in optical calculations. This work improves the accuracy of a previous model by including the higher-order shape parameters of the cornea. METHODS. The right eye biometry of 312 subjects (40.8 +/- 11.0 years of age) were measured with an autorefractometer, a Scheimpflug camera, an optical biometer, and a ray tracing aberrometer. The corneal shape parameters, exported as Zernike coefficients, were converted to eigenvectors for dimensional reduction. The remaining 18 parameters were modeled as a sum of two multivariate Gaussians, from which an unlimited number of synthetic data sets (SyntEyes) were generated. After conversion back to Zernike coefficients, the data were introduced into ray tracing software. RESULTS. The mean values of nearly all SyntEyes parameters were statistically equal to those of the original data (two one-sided t-test, P > 0.05/109, Bonferroni correction). The variability of the SyntEyes parameters was similar to the original data for most important shape parameters and intraocular distances (F-test, P < 0.05/109), but significantly lower for the higher-order shape parameters (F-test, P > 0.05/109). The same was seen for the correlations between higher-order shape parameters. After applying simulated cataract or refractive surgery to the SyntEyes model, a very close resemblance to previously published clinical outcome data was seen. CONCLUSIONS. The SyntEyes model produces synthetic biometry that closely resembles clinically measured data, including the normal biological variations in the general population.
引用
收藏
页码:683 / 691
页数:9
相关论文
共 50 条
  • [21] Contrast sensitivity and higher-order aberrations in Keratoconus subjects
    Shneor, Einat
    Pinero, David P.
    Doron, Ravid
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [22] Analysis of Higher-Order Aberrations in a Large Clinical Population
    Hartwig, Andreas
    Atchison, David A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (12) : 7862 - 7870
  • [23] Dynamic changes in higher-order aberrations after correction of lower-order aberrations with adaptive optics in myopic and emmetropic eyes
    Jiang, Yanglin
    Wang, Yan
    Zhang, Jiamei
    Chen, Xiaoqin
    Li, Lihua
    Zhao, Haoxin
    Wang, Rui
    Dai, Yun
    APPLIED OPTICS, 2018, 57 (03) : 514 - 520
  • [24] Visual outcomes and higher-order aberrations in eyes implanted with hybrid extended depth of focus intraocular lens
    Kenia, Vaishal P.
    Kenia, Raj V.
    Mudaliya, Laxmi
    Pirdankar, Onkar H.
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2023, 13 (03) : 341 - 345
  • [25] Hybrid higher-order total variation model for multiplicative noise removal
    Liu, Pengfei
    IET IMAGE PROCESSING, 2020, 14 (05) : 862 - 873
  • [26] Monochromatic higher order aberrations in highly myopic eyes with Staphyloma
    Delgado-Tirado, Santiago
    Lopez-Miguel, Alberto
    Baez-Peralta, Yazmin
    Gonzalez-Buendia, Lucia
    Fernandez, Itziar
    Alio, Jorge L.
    Maldonado, Miguel J.
    Coco-Martin, Rosa M.
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [27] Fallacy of higher-order reflective constructs
    Mikulic, Josip
    TOURISM MANAGEMENT, 2022, 89
  • [28] Corneal higher-order aberrations Cross Mark and higher-order Strehl ratio after aberration-free ablation profile to treat compound myopic astigmatism
    Brenner, Luis F.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (12) : 2672 - 2682
  • [29] Visual Function and Higher-Order Aberrations in Eyes After Corneal Transplantation: How to Improve Postoperative Quality of Vision
    Yamaguchi, Takefumi
    Satake, Yoshiyuki
    Dogru, Murat
    Ohnuma, Kazuhiko
    Negishi, Kazuno
    Shimazaki, Jun
    CORNEA, 2015, 34 : S128 - S135
  • [30] A higher-order model of consumer brand engagement and its impact on loyalty intentions
    Dwivedi, Abhishek
    JOURNAL OF RETAILING AND CONSUMER SERVICES, 2015, 24 : 100 - 109