Accuracy of Computed Tomography Attenuation Value of Lumbar Vertebra to Assess Bone Mineral Density

被引:5
作者
Chia, Kok King [1 ,2 ]
Haron, Juhara [1 ]
Malek, Nik Fatimah Salwati Nik [2 ]
机构
[1] Univ Sains Malaysia, Sch Med Sci, Dept Radiol, Kubang Kerian 1615O, Kelantan, Malaysia
[2] Hosp Sultanah Bahiyah, Dept Radiol, Alor Setar, Kedah, Malaysia
来源
MALAYSIAN JOURNAL OF MEDICAL SCIENCES | 2021年 / 28卷 / 01期
关键词
osteoporosis; post-menopausal bone loss; multidetector computed tomography; dual-energy X-ray absorptiometry; lumbar vertebrae; compression fracture; metabolic bone disease;
D O I
10.21315/mjms2021.28.1.6
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Computed tomography (CT) attenuation (Hounsfield unit [HU]) value of lumbar vertebra may provide an alternative method in the detection of osteoporosis during CT scans. Methods: A cross-sectional study on 50 patients of age 50 and above with contrast-enhanced CT (CECT) and dual-energy X-ray absorptiometry (DXA) was conducted from November 2018 to November 2019. Single region of interest (ROI) was placed at the anterior trabecular part of L1 vertebra on CELT to obtain HU value. Correlation of Cr HU value of L1 vertebra and DXA T-score, interrater reliability agreement between HU value of L1 vertebra and T-score in determining groups of with and without osteoporosis, ROC curve analysis for diagnostic accuracy and cut-off value of CT for detection of osteoporosis were identified. Results: Significant correlation between HU value of L1 vertebra and L1 T-score (r = 0.683)/lowest skeletal T-score (r = 0.703) (P < 0.001). Substantial agreement between HU value of L1 vertebra and DXA in determining the groups with and without osteoporosis (k = 0.8; P < 0.001). The area under the receiver operating characteristic (AUROC) curve was 0.93 (95% CI: 0.86, 1.00) using HU value (P < 0.001). Cut-off value for osteoporosis was 149 HU. Conclusion: HU value of lumbar vertebra is an effective alternative for the detection of osteoporosis with high diagnostic accuracy in hospitals without DXA facility.
引用
收藏
页码:41 / 50
页数:10
相关论文
共 16 条
[1]   Opportunistic screening for osteoporosis by routine CT in Southern Europe [J].
Alacreu, Elena ;
Moratal, David ;
Arana, Estanislao .
OSTEOPOROSIS INTERNATIONAL, 2017, 28 (03) :983-990
[2]  
[Anonymous], 2012, CLIN GUID MAN OST
[3]   Hounsfield unit for the diagnosis of bone mineral density disease: A proof of concept study [J].
Batawil, N. ;
Sabiq, S. .
RADIOGRAPHY, 2016, 22 (02) :E93-E98
[4]  
Chan P. J., 2014, International Journal of Osteoporosis & Metabolic Disorders, V7, P1
[5]  
Cheung Ching-Lung, 2018, Osteoporos Sarcopenia, V4, P16, DOI 10.1016/j.afos.2018.03.003
[6]  
Dobbs M B, 1999, Iowa Orthop J, V19, P43
[7]   Epidemiology of Fracture Risk With Advancing Age [J].
Ensrud, Kristine E. .
JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2013, 68 (10) :1236-1242
[8]  
International Osteoporosis Foundation, 2017, Osteoporosis Incidence and Burden
[9]  
Kanis JA, 2008, TECHNICAL REPORT
[10]  
Malaysian Osteoporosis Society, 2010, HOSP CTR DXA SCANN, V2010