Biocompatibility of new bioactive resin composite versus calcium silicate cements: an animal study

被引:37
作者
Abou ElReash, Ashraf [1 ]
Hamama, Hamdi [2 ]
Abdo, Walied [3 ]
Wu, Qiqi [1 ]
El-Din, Ahmed Zaen [4 ]
Xie Xiaoli [1 ]
机构
[1] Cent South Univ, Xiangya Sch Stomatol, Dept Endodont, Xiangya Rd 72 Kaifu, Changsha 410078, Hunan, Peoples R China
[2] Mansoura Univ, Fac Dent, Dept Operat Dent, Mansoura, Egypt
[3] Kafrelsheikh Univ, Fac Vet Med, Dept Pathol, Kafrelsheikh, Egypt
[4] Delta Univ Sci & Technol, Fac Oral & Dent Med, Dept Conservat Dent, Int Coastal Rd, Mansoura, Dakhliya, Egypt
关键词
Bioactive composite; Calcium silicate; Caspase; 3; MTA-HP; alpha-SMA; MINERAL TRIOXIDE AGGREGATE; CHEMICAL-PHYSICAL PROPERTIES; CONNECTIVE-TISSUE; FILLING MATERIALS; MTA; CYTOTOXICITY; EXPRESSION; RESPONSES; WHITE;
D O I
10.1186/s12903-019-0887-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background The purpose of this study was to compare the biocompatibility of three bioactive materials, namely ACTIVA bioactive restorative resin composite, iRoot BP plus and Mineral Trioxide Aggregate (MTA) Angelus-HP. Methods Seventy-five Wistar male rats were subjected to subcutaneous implantation of four polyethylene tubes; one empty tube was used as control (Group 1), and the other tubes were filled with ACTIVA (Group 2), iRoot BP (Group 3) and MTA-HP (Group 4). Then, the rats were subdivided into 3 groups according to the sacrification time into one, two and 4 weeks (n = 25 rats). Tissue specimens were submitted to histopathological and immunohistochemical analysis of alpha-SMA and caspase 3. Results The one-way Anova test revealed that ACTIVA group exhibited minimal inflammation in comparison to calcium silicate cements (iRoot BP and MTA-HP groups). iRoot BP group significantly revealed a more severe degree of chronic inflammation in comparison to other groups (P < 0.05). ACTIVA group showed marked regression of inflammation and fibrosis comparable to the control, while iRoot BP group revealed remarkable fibrosis and calcification, with less degrees in MTA-HP group (P < 0.05). Immunostaining of both alpha-SMA and caspase 3 revealed lower indexes in ACTIVA group consistent with the control (P < 0.05). Conclusions ACTIVA showed a higher degree of biocompatibility to subcutaneous tissues in comparison to both iRoot BP and MTA-HP cements in regard to decrease the intensity of inflammation, with subsequent fibrous connective tissue remodeling and better healing patterns.
引用
收藏
页数:10
相关论文
共 51 条
[1]   Biological responses to materials [J].
Anderson, JM .
ANNUAL REVIEW OF MATERIALS RESEARCH, 2001, 31 :81-110
[2]  
[Anonymous], MIN TRIOX AGGR HIGH
[3]  
[Anonymous], SCIENTIFICWORLDJOURN
[4]  
[Anonymous], ACT BIOACT REST MAT
[5]   TheraCal LC: From Biochemical and Bioactive Properties to Clinical Applications [J].
Arandi, Naji Ziad ;
Rabi, Tarek .
INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
[6]   Cytotoxicity and Genotoxicity of Root Canal Sealers Based on Mineral Trioxide Aggregate [J].
Bin, Claudia V. ;
Valera, Marcia C. ;
Camargo, Samira E. A. ;
Rabelo, Sylvia B. ;
Silva, Gleyce O. ;
Balducci, Ivan ;
Camargo, Carlos Henrique R. .
JOURNAL OF ENDODONTICS, 2012, 38 (04) :495-500
[7]   Marginal Gaps between 2 Calcium Silicate and Glass lonomer Cements and Apical Root Dentin [J].
Biocanin, Vladimir ;
Antonijevic, Djordje ;
Postic, Srdan ;
Ilic, Dragan ;
Vukovic, Zorica ;
Milic, Marija ;
Fan, Yifang ;
Li, Zhiyu ;
Brkovic, Bozidar ;
Duric, Marija .
JOURNAL OF ENDODONTICS, 2018, 44 (05) :816-821
[8]   Biocompatibility of retrograde root filling materials: A review [J].
Bodrumlu, Emre .
AUSTRALIAN ENDODONTIC JOURNAL, 2008, 34 (01) :30-35
[9]   Presence of arsenic in different types of MTA and white and gray Portland cement [J].
Bramante, Clovis Monteiro ;
Cardoso Oliveira Demarchi, Ana Claudia ;
de Moraes, Ivaldo Gomes ;
Bernadineli, Norberti ;
Garcia, Roberto Brandao ;
Spangberg, Lars S. W. ;
Hungaro Duarte, Marco Antonio .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 106 (06) :909-913
[10]  
Buonavoglia A, 2017, J BIOL REG HOMEOS AG, V31, P1