A review of current trends and advances in modern bio-analytical methods: Chromatography and sample preparation

被引:436
作者
Novakova, Lucie [1 ]
Vlckova, Hana [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic
关键词
UHPLC; HTLC; PHW-LC; HILIC; Monolith; Fused core columns; Bio-analytical method; Sample preparation; Microextraction; SPE; LLE; RAM; MIP; TFC; MEPS; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE MICROEXTRACTION; TANDEM MASS-SPECTROMETRY; BAR SORPTIVE EXTRACTION; RESTRICTED-ACCESS MATERIALS; MOLECULARLY IMPRINTED POLYMERS; PACKED SYRINGE MEPS; LC-MS/MS METHOD; NONSTEROIDAL ANTIINFLAMMATORY DRUGS; SPIN COLUMN EXTRACTION;
D O I
10.1016/j.aca.2009.10.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Any bio-analytical method includes several steps, all of them being important in order to achieve reliable results. The first step is taking aliquots of samples for the analysis, followed by the extraction procedure and sample clean-up, chromatographic analysis and detection. Chromatographic methods, particularly liquid chromatography, are the methods of choice in bio-analytical laboratories. Current trends in fast liquid chromatographic separations involve monolith technology, fused core columns, high temperature liquid chromatography and ultra-high performance liquid chromatography (UHPLC). UHPLC has recently become a wide-spread analytical technique in many laboratories which focus on fast and sensitive bio-analytical assays. The key advantages of UHPLC are the increased speed of analysis, higher separation efficiency and resolution, higher sensitivity and much lower solvent consumption as compared to other analytical approaches. This is all enabled by specially designed instruments and sub-2-microne particle packed analytical columns. There is a great contrast between ultra-fast chromatographic analysis and conventional sample preparation, which remains highly labor-intensive and time-consuming. Conventional sample preparation techniques including SPE, solid phase extraction; LLE, liquid-liquid extraction; PP, protein precipitation and many modern approaches (RAM, restricted access material; MIP, molecularly imprinted polymers; SPME, solid phase microextraction; LLME, liquid-liquid microextraction; MEPS, microextraction by packed sorbent and many others) have also been featured as fundamental and critical step of bio-analytical methods. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 35
页数:28
相关论文
共 279 条
[1]   Microextraction in packed syringe/liquid chromatography/electrospray tandem mass spectrometry for quantification of olomoucine in human plasma samples [J].
Abdel-Rehim, M ;
Skansen, P ;
Vita, M ;
Hassan, Z ;
Blomberg, L ;
Hassan, M .
ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) :35-39
[2]   Microextraction in packed syringe (MEPS) for liquid and gas chromatographic applications. Part II - Determination of ropivacaine and its metabolites in human plasma samples using MEPS with liquid chromatography/tandem mass spectrometry [J].
Abdel-Rehim, M ;
Altun, Z ;
Blomberg, L .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (12) :1488-1493
[3]   New trend in sample preparation: on-line microextraction in packed syringe for liquid and gas chromatography applications - I. Determination of local anaesthetics in human plasma samples using gas chromatography-mass spectrometry [J].
Abdel-Rehim, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 801 (02) :317-321
[4]   MEPS as a rapid sample preparation method to handle unstable compounds in a complex matrix:: Determination of AZD3409 in plasma samples utilizing MEPS-LC-MS-MS [J].
Abdel-Rehim, Mohamed ;
Andersson, Anita ;
Breitholtz-Emanuelsson, Anna ;
Sandberg-Stall, Maria ;
Brunfelter, Kristina ;
Pettersson, Karl-Johan ;
Norsten-Hoog, Carina .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (06) :518-523
[5]   Simultaneous determination of busulphan in plasma samples by liquid chromatography-electrospray ionization mass spectrometry utilizing microextraction in packed syringe (MEPS) as on-line sample preparation method [J].
Abdel-Rehim, Mohamed ;
Hassan, Zuzana ;
Skansem, Patrik ;
Hassan, Moustapha .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (20) :3029-3041
[6]   Analysis of thyreostatic drugs in thyroid samples by Ultra-Performance Liquid Chromatography tandem mass spectrometry detection [J].
Abuinb, S. ;
Centrich, F. ;
Rubies, A. ;
Companyo, R. ;
Prat, M. D. .
ANALYTICA CHIMICA ACTA, 2008, 617 (1-2) :184-191
[7]   UPLC-MS/MS determination of doxazosine in human plasma [J].
Al-Dirbashi, Osama Y. ;
Aboul-Enein, Hassan Y. ;
Jacob, Minnie ;
Al-Qahtani, Khalid ;
Rashed, Mohamed S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (08) :1439-1443
[8]   Quantitative-profiling of bile acids and their conjugates in mouse liver, bile, plasma, and urine using LC-MS/MS [J].
Alnouti, Yazen ;
Csanaky, Ivan L. ;
Klaassen, Curtis D. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 873 (02) :209-217
[9]   New trends in sample preparation: on-line microextraction in packed syringe (MEPS) for LC and GC applications Part III: Determination and validation of local anaesthetics in human plasma samples using a cation-exchange sorbent, and MEPS-LC-MS-MS [J].
Altun, Z ;
Abdel-Rehim, M ;
Blomberg, LG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2) :129-135
[10]   Study of the factors affecting the performance of microextraction by packed sorbent (MEPS) using liquid scintillation counter and liquid chromatography-tandem mass spectrometry [J].
Altun, Zeki ;
Abdel-Rehim, Mohamed .
ANALYTICA CHIMICA ACTA, 2008, 630 (02) :116-123