Seismic behavior of corrugated double-skin composite wall (DSCW) with concrete-filled steel tubes: Experimental investigation

被引:18
作者
Zhou, Ji [1 ]
Chen, Zongping [1 ,2 ]
Liao, Haoyu [1 ]
Tang, Jiyu [1 ,3 ]
机构
[1] Guangxi Univ, Coll Civil Engn & Architecture, Nanning 530004, Peoples R China
[2] Guangxi Univ, Key Lab Disaster Prevent & Struct Safety, Chinese Minist Educ, Nanning 530004, Peoples R China
[3] China Construct Eighth Bur Investment Dev Co Ltd, Guangxi Branch, Nanning 530004, Peoples R China
关键词
Corrugated double-skin composite wall; Seismic behavior; Axial compression ratio; Corrugation direction and shape; Connector type; Lateral strength; OUT-OF-PLANE; PERFORMANCE; DESIGN;
D O I
10.1016/j.engstruct.2021.113632
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the seismic behavior of corrugated double-skin composite wall (DSCW) with concrete-filled steel tube boundary elements. Fifteen 1/3-scale DSCW specimens, varying in shear span ratio, axial compression ratio, corrugation direction and shape, connector type and steel faceplate profile, were tested under cyclic loading. All specimens except W15 failed in flexural failure. The cyclic response of vertical corrugated DSCW was much better than that of horizontal corrugated DSCW. Compared to flat DSCW, corrugated DSCW, even with a 20% reduction in the concrete cross-sectional area, had considerably higher peak load, ductility ratio and energy dissipation. The setting of connectors slowed down the damage rate of the corrugated DSCW in the failure stage, and also significantly improved the peak load and ductility of the corrugated DSCW with lambda = 1.5. Increasing the shear span ratio significantly reduced the peak load and initial stiffness of the DSCW, but did not affect the ductility and energy dissipation. The corrugated DSCW, failed in flexural-dominated mode, had excellent collapse resistance, achieving a drift ratio exceeding 2% and a ductility ratio greater than 3.3, and it was recommended to take n = 0.3 as the limit value of axial compression ratio of corrugated DSCW. Moreover, the average ratio of P-t/P-c was 1.082 with a mean absolute error of 0.068 and a root mean square error of 0.084, indicating that the calculated value of proposed formulas for calculating the lateral strength of vertical corrugated DSCW can reflect the measured data well.
引用
收藏
页数:25
相关论文
共 34 条
[1]  
[Anonymous], 2015, JGJ101-2015
[2]  
[Anonymous], 1997, ASTM E.8M
[3]  
[Anonymous], 2010, GB50011-2010
[4]  
[Anonymous], 2018, C39C39M18 ASTM INT
[5]  
[Anonymous], 2014, GB50936-2014
[6]  
[Anonymous], 2010, NATL CCS COMPREHENSI
[7]  
[Anonymous], 2010, Code for design of concrete structures
[8]  
[Anonymous], 2014, ACI Committee 318-14
[9]  
[Anonymous], 2020, GB50205-2020
[10]   Behavior of geopolymeric recycled aggregate concrete-filled FRP tube (GRACFFT) columns under lateral cyclic loading [J].
Cai, Jingming ;
Hao, Haoyu ;
Ozbakkaloglu, Togay ;
Zhang, Yamei ;
Pan, Jinlong .
ENGINEERING STRUCTURES, 2020, 222