Prediction of ischial ramal angle for transfemoral ischial containment sockets

被引:2
|
作者
Quigley, Matthew [1 ]
Dillon, Michael P. [1 ]
Fernandez, Richard G. D. [1 ]
Erbas, Bircan [2 ]
Briggs, Chris [3 ]
机构
[1] La Trobe Univ, Plenty Rd, Melbourne, Vic 3086, Australia
[2] La Trobe Univ, Coll Sci Hlth & Engn, Melbourne, Vic, Australia
[3] Univ Melbourne, Sch Biomed Sci, Parkville, Vic, Australia
关键词
Amputation; anthropometry; computed tomography; ischial containment; pelvic morphology; prediction; prosthesis; ischial ramal angle; socket; transfemoral; SEX; GROWTH;
D O I
10.1177/0309364618789439
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A well-fitting and comfortable ischial containment socket relies on accurately replicating the transverse plane angle of the ischium and ischial ramus angle, inside the medial socket brim. Prediction of the ischial ramus angle, may provide a way to determine the ischial ramus angle without in vivo measurement. Objectives: To determine the accuracy with which the ischial ramus angle could be predicted and identify which variables contributed significantly to the prediction. Study design: Cross-sectional study. Methods: Computed tomography scans were randomly sampled from a cadaveric database (n = 200). Standard multiple regression models were developed to predict the ischial ramus angle based on pelvic measures. Results: The regression model explained 10.5% of the variance in ischial ramus angle (p = 0.018). The standard error of the estimate was 11.32 degrees. While regression models by sex explained a larger proportion of the variance, the resulting accuracy was not improved. Conclusion: The regression models explained a small proportion of variance in ischial ramus angle. The average error associated with the prediction was too large to accurately predict the ischial ramus angle for use in clinical practice. Contrary to commonly held beliefs, there was no statistically significant difference in ischial ramus angle between sexes.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 12 条
  • [1] Prediction of Skeletal Medial-Lateral for transfemoral ischial containment sockets
    Dillon, Michael P.
    Fernandez, Richard G. D.
    Erbas, Bircan
    Briggs, Chris
    Quigley, Matthew
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2016, 53 (02): : 253 - 262
  • [2] Comparison of Ischial Containment and Subischial Sockets Effect on Gait Biomechanics in People With Transfemoral Amputation: A Randomized Crossover Trial
    Fatone, Stefania
    Stine, Rebecca
    Caldwell, Ryan
    Angelico, John
    Gard, Steven A.
    Oros, Michael
    Major, Matthew J.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2022, 103 (08): : 1515 - 1523
  • [3] Comparison of Ischial Containment and Subischial Sockets on Comfort, Function, Quality of Life, and Satisfaction With Device in Persons With Unilateral Transfemoral Amputation: A Randomized Crossover Trial
    Fatone, Stefania
    Caldwell, Ryan
    Angelico, John
    Stine, Rebecca
    Kim, Kwang-Youn
    Gard, Steven
    Oros, Michael
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2021, 102 (11): : 2063 - +
  • [4] Transfemoral sockets with vacuum-assisted suspension comparison of hip kinematics, socket position, contact pressure, and preference: Ischial containment versus brimless
    Kahle, Jason T.
    Highsmith, M. Jason
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2013, 50 (09): : 1241 - 1251
  • [5] Energy cost of walking in transfemoral amputees: Comparison between Marlo Anatomical Socket and Ischial Containment Socket
    Traballesi, Marco
    Delussu, Anna Sofia
    Averna, Tiziano
    Pellegrini, Roberto
    Paradisi, Francesco
    Brunelli, Stefano
    GAIT & POSTURE, 2011, 34 (02) : 270 - 274
  • [6] Prediction of the skeletal medio-lateral dimension using non-invasive anthropometric measurements for the provision of ischial containment sockets: A pilot study
    Dillon, Michael P.
    Laux, Stefan
    Fernandez, Richard G. D.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2014, 38 (02) : 133 - 139
  • [7] Transfemoral interfaces with vacuum assisted suspension comparison of gait, balance, and subjective analysis: Ischial containment versus brimless
    Kahle, Jason T.
    Highsmith, M. Jason
    GAIT & POSTURE, 2014, 40 (02) : 315 - 320
  • [8] Effect of the ischial support on muscle force estimation during transfemoral walking
    Fougeron, Nolwenn
    Bonnet, Xavier
    Panhelleux, Brieuc
    Rose, Jean-Loic
    Rohan, Pierre-Yves
    Pillet, Helene
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2025, 49 (01) : 51 - 59
  • [9] Angle of mediolateral episiotomy using the ischial tuberosity as a reference point
    Karbanova, Jaroslava
    Landsmanova, Jana
    Novotny, Zdenek
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2009, 107 (02) : 157 - 157
  • [10] Finite element analysis of the stump-ischial containment socket interaction: a technical note
    Fougeron, Nolwenn
    Rohan, Pierre-Yves
    Rose, Jean-Loic
    Bonnet, Xavier
    Pillet, Helene
    MEDICAL ENGINEERING & PHYSICS, 2022, 105