Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring

被引:264
作者
Wang, Bo [1 ]
Zhao, Chuanzhen [2 ,3 ]
Wang, Zhaoqing [1 ]
Yang, Kyung-Ae [4 ]
Cheng, Xuanbing [1 ,5 ]
Liu, Wenfei [2 ,3 ]
Yu, Wenzhuo [1 ]
Lin, Shuyu [1 ]
Zhao, Yichao [1 ,5 ]
Cheung, Kevin M. [2 ,3 ]
Lin, Haisong [1 ]
Hojaiji, Hannaneh [1 ]
Weiss, Paul S. [2 ,3 ,5 ,6 ]
Stojanovic, Milan N. [4 ,7 ]
Tomiyama, A. Janet [8 ]
Andrews, Anne M. [2 ,3 ,9 ,10 ,11 ]
Emaminejad, Sam [1 ,6 ]
机构
[1] Univ Calif Los Angeles, Dept Elect & Comp Engn, Interconnected & Integrated Bioelect Lab I2BL, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Chem & Biochem, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Calif NanoSyst Inst, Los Angeles, CA 90095 USA
[4] Columbia Univ, Dept Med, Div Expt Therapeut, New York, NY 10032 USA
[5] Univ Calif Los Angeles, Dept Mat Sci & Engn, Los Angeles, CA 90095 USA
[6] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[7] Columbia Univ, Dept Biomed Engn, New York, NY 10032 USA
[8] Univ Calif Los Angeles, Dept Psychol, Los Angeles, CA 90095 USA
[9] Univ Calif Los Angeles, Dept Psychiat & Biobehav Sci, Los Angeles, CA 90095 USA
[10] Univ Calif Los Angeles, Semel Inst Neurosci & Human Behav, Los Angeles, CA 90095 USA
[11] Univ Calif Los Angeles, Hatos Ctr Neuropharmacol, Los Angeles, CA 90095 USA
基金
美国国家科学基金会;
关键词
SALIVARY CORTISOL; ECCRINE SWEAT; IMMUNOASSAYS; PERSPIRATION; DEPRESSION; BIOMARKERS; DIAGNOSIS; ANXIETY; SENSORS; SERUM;
D O I
10.1126/sciadv.abk0967
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Wearable technologies for personalized monitoring require sensors that track biomarkers often present at low levels. Cortisol-a key stress biomarker-is present in sweat at low nanomolar concentrations. Previous wearable sensing systems are limited to analytes in the micromolar-millimolar ranges. To overcome this and other limitations, we developed a flexible field-effect transistor (FET) biosensor array that exploits a previously unreported cortisol aptamer coupled to nanometer-thin-film In2O3 FETs. Cortisol levels were determined via molecular recognition by aptamers where binding was transduced to electrical signals on FETs. The physiological relevance of cortisol as a stress biomarker was demonstrated by tracking salivary cortisol levels in participants in a Trier Social Stress Test and establishing correlations between cortisol in diurnal saliva and sweat samples. These correlations motivated the development and on-body validation of an aptamer-FET array-based smartwatch equipped with a custom, multichannel, self-referencing, and autonomous source measurement unit enabling seamless, real-time cortisol sweat sensing.
引用
收藏
页数:15
相关论文
共 83 条
[11]   The cortisol awakening response: More than a measure of HPA axis function [J].
Clow, Angela ;
Hucklebridge, Frank ;
Stalder, Tobias ;
Evans, Phil ;
Thorn, Lisa .
NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 2010, 35 (01) :97-103
[12]   Thioflavin T as a fluorescence light-up probe for G4 formation [J].
de la Faverie, Amandine Renaud ;
Guedin, Aurore ;
Bedrat, Amina ;
Yatsunyk, Liliya A. ;
Mergny, Jean-Louis .
NUCLEIC ACIDS RESEARCH, 2014, 42 (08) :e65
[13]   Human saliva cortisone and cortisol simultaneous analysis using reverse phase HPLC technique [J].
De Palo, Elio F. ;
Antonelli, Giorgia ;
Benetazzo, Arianna ;
Prearo, Maddalena ;
Gatti, Rosalba .
CLINICA CHIMICA ACTA, 2009, 405 (1-2) :60-65
[14]   Acute stressors and cortisol responses: A theoretical integration and synthesis of laboratory research [J].
Dickerson, SS ;
Kemeny, ME .
PSYCHOLOGICAL BULLETIN, 2004, 130 (03) :355-391
[15]  
Elverson C.A., 2005, NEWBORN INFANT NURSI, V5, P159, DOI DOI 10.1053/J.NAINR.2005.09.002
[16]   Autonomous sweat extraction and analysis applied to cystic fibrosis and glucose monitoring using a fully integrated wearable platform [J].
Emaminejad, Sam ;
Gao, Wei ;
Wu, Eric ;
Davies, Zoe A. ;
Nyein, Hnin Yin Yin ;
Challa, Samyuktha ;
Ryan, Sean P. ;
Fahad, Hossain M. ;
Chen, Kevin ;
Shahpar, Ziba ;
Talebi, Salmonn ;
Milla, Carlos ;
Javey, Ali ;
Davis, Ronald W. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2017, 114 (18) :4625-4630
[17]   Autonomous, Real-Time Monitoring Electrochemical Aptasensor for Circadian Tracking of Cortisol Hormone in Sub-microliter Volumes of Passively Eluted Human Sweat [J].
Ganguly, Antra ;
Lin, Kai Chun ;
Muthukumar, Sriram ;
Prasad, Shalini .
ACS SENSORS, 2021, 6 (01) :63-72
[18]   Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis [J].
Gao, Wei ;
Emaminejad, Sam ;
Nyein, Hnin Yin Yin ;
Challa, Samyuktha ;
Chen, Kevin ;
Peck, Austin ;
Fahad, Hossain M. ;
Ota, Hiroki ;
Shiraki, Hiroshi ;
Kiriya, Daisuke ;
Lien, Der-Hsien ;
Brooks, George A. ;
Davis, Ronald W. ;
Javey, Ali .
NATURE, 2016, 529 (7587) :509-+
[19]   Breast milk levels of cortisol and Secretory Immunoglobulin A (SIgA) differ with maternal mood and infant neuro-behavioral functioning [J].
Hart, S ;
Boylan, LM ;
Border, B ;
Carroll, SR ;
McGunegle, D ;
Lampe, RM .
INFANT BEHAVIOR & DEVELOPMENT, 2004, 27 (01) :101-106
[20]   Accessing analytes in biofluids for peripheral biochemical monitoring [J].
Heikenfeld, Jason ;
Jajack, Andrew ;
Feldman, Benjamin ;
Granger, Steve W. ;
Gaitonde, Supriya ;
Begtrup, Gavi ;
Katchman, Benjamin A. .
NATURE BIOTECHNOLOGY, 2019, 37 (04) :407-419