Simultaneous determination of uric acid and creatinine in urine by an eco-friendly solvent-free high performance liquid chromatographic method

被引:117
作者
Jen, JF [1 ]
Hsiao, SL [1 ]
Liu, KH [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 40217, Taiwan
关键词
uric acid; creatinine; environmental-friendly; high performance liquid chromatography;
D O I
10.1016/S0039-9140(02)00377-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid, and eco-friendly analytical method for simultaneous determination of uric acid and creatinine in urine applying high performance liquid chromatography (HPLC) is described. After dilution, de-protein, and filtration, the sample solution was injected to separate the species with C-18 column by an eluent containing 0.05 M ammonium phosphate buffer at pH 7.4. An UV detector was used to monitor the separation of species at 235 nm. Optimum conditions for separation and detection were investigated. Results indicated that under optimized condition measurements were achieved within 13 min. The detection limits were 0.127 and 0.156 mug ml(-1) for uric acid and creatinine respectively. The recovery was 95% (0.57% RSD) for uric acid and 99.2% (0.98% RSD) for creatinine, from five measurements. Real urine specimens were tested. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:711 / 717
页数:7
相关论文
共 21 条
[1]   Quantification of urinary uric acid in the presence of thymol and thimerosal by high-performance liquid chromatography [J].
Chen, YM ;
Pietrzyk, RA ;
Whitson, PA .
JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) :187-192
[2]   Reversed phase liquid chromatography of organic hydrocarbons with water as the mobile phase [J].
Foster, MD ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2838-2844
[3]   Simultaneous determination of the urinary metabolites of toluene, xylene and styrene using high-performance capillary electrophoresis - Comparison with high-performance liquid chromatography [J].
Fujii, T ;
Kawabe, S ;
Horike, T ;
Taguchi, T ;
Ogata, M .
JOURNAL OF CHROMATOGRAPHY B, 1999, 730 (01) :41-47
[4]   Retention and selectivity effects of coating octadecylsilica stationary phases with low molecular weight alcohols in reversed-phase liquid chromatography using water as mobile phase [J].
Hu, WZ ;
Haddad, PR .
ANALYTICAL COMMUNICATIONS, 1998, 35 (02) :49-52
[5]   Determination of uremic toxins in biofluids: creatinine, creatine, uric acid and xanthines [J].
Kochansky, CJ ;
Strein, TG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 747 (1-2) :217-227
[6]  
KOCK R, 1993, EUR J CLIN CHEM CLIN, V31, P303
[7]  
KROLL MH, 1986, CLIN CHEM, V32, P446
[8]  
LEVEY AS, 1988, ANNU REV MED, V39, P465, DOI 10.1146/annurev.med.39.1.465
[9]   SIMULTANEOUS DETERMINATION OF PSEUDOURIDINE AND CREATININE IN URINE OF NORMAL-CHILDREN AND PATIENTS WITH LEUKEMIA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LI, YT ;
WANG, SS ;
ZHONG, N .
BIOMEDICAL CHROMATOGRAPHY, 1992, 6 (04) :191-193
[10]   Subcritical water chromatography with flame ionization detection [J].
Miller, DJ ;
Hawthorne, SB .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :623-627