摘要
The patient dose in computed tomography (CT) imaging is linked to measurement noise. Various noise-reduction techniques have been developed that adapt structure preserving filters like anisotropic diffusion or bilateral filters to CT noise properties. We introduce a structure adaptive sinogram (SAS) filter that incorporates the specific properties of the CT measurement process. It uses a point-based forward projector to generate a local structure representation called ray contribution mask (RCM). The similarities between neighboring RCMs are used in an enhanced variant of the bilateral filtering concept, where the photometric similarity is replaced with the structural similarity. We evaluate the performance in four different scenarios: The robustness against reconstruction artifacts is demonstrated by a scan of a high-resolution-phantom. Without changing the modulation transfer function (MTF) nor introducing artifacts, the SAS filter reduces the noise level by 13.6%. The image sharpness and noise reduction capabilities are visually assessed on in vivo patient scans and quantitatively evaluated on a simulated phantom. Unlike a standard bilateral filter, the SAS filter preserves edge information and high-frequency components of organ textures well. It shows a homogeneous noise reduction behavior throughout the whole frequency range. The last scenario uses a simulated edge phantom to estimate the filter MTF for various contrasts: the noise reduction for the simple edge phantom exceeds 80%. For low contrasts at 55 Hounsfield units (HU), the mid-frequency range is slightly attenuated, at higher contrasts of approximately 100 HU and above, the MTF is fully preserved.
引用
收藏
页码:1228 / 1239
页数:12
相关论文
共 26 条
[1]  
Borsdorf A., 2008, 2008 IEEE Nuclear Science Symposium Conference Record, P5335, DOI DOI 10.1109/NSSMIC.2008.4774438.
[2]   Wavelet Based Noise Reduction in CT-Images Using Correlation Analysis [J].
Borsdorf, Anja ;
Raupach, Rainer ;
Flohr, Thomas ;
Hornegger, Joachim .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (12) :1685-1703
[3]   IMAGE SELECTIVE SMOOTHING AND EDGE-DETECTION BY NONLINEAR DIFFUSION [J].
CATTE, F ;
LIONS, PL ;
MOREL, JM ;
COLL, T .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 1992, 29 (01) :182-193
[4]   EFFECT OF CT NOISE ON DETECTABILITY OF TEST OBJECTS [J].
CHEW, E ;
WEISS, GH ;
BROOKS, RA ;
DICHIRO, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 131 (04) :681-685
[5]   Signal-to-noise optimization of medical imaging systems [J].
Cunningham, IA ;
Shaw, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03) :621-632
[6]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[7]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[8]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[9]  
Hilts M., 2004, Journal of Physics: Conference Series, V3, P252, DOI 10.1088/1742-6596/3/1/040
[10]   Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise [J].
Hsieh, J .
MEDICAL PHYSICS, 1998, 25 (11) :2139-2147