AntDAS: Automatic Data Analysis Strategy for UPLC-QTOF-Based Nontargeted Metabolic Profiling Analysis

被引:43
作者
Fu, Hai-Yan [1 ]
Guo, Xiao-Ming [1 ]
Zhang, Yue-Ming [2 ]
Song, Jing-Jing [4 ]
Zheng, Qing-Xia [5 ]
Liu, Ping-Ping [5 ]
Lu, Peng [5 ]
Chen, Qian-Si [5 ]
Yu, Yong-Jie [2 ,3 ]
She, Yuanbin [6 ]
机构
[1] South Cent Univ Nationalities, Sch Pharmaceut Sci, Wuhan 430074, Hubei, Peoples R China
[2] Ningxia Med Univ, Coll Pharm, Yinchuan 750004, Peoples R China
[3] Ningxia Med Univ, Ningxia Engn & Technol Res Ctr Modernizat Hui Med, Yinchuan 750004, Peoples R China
[4] Ningxia Inst Cultural Rel & Archeol, Yinchuan 750001, Peoples R China
[5] CNTC, Zhengzhou Tobacco Res Inst, China Tobacco Gene Res Ctr, Zhengzhou 450001, Henan, Peoples R China
[6] ZhengJiang Univ Technol, Hangzhou 310014, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
MASS-SPECTROMETRY DATA; LC-MS DATA; IMPROVED PEAK DETECTION; CHROMATOGRAPHIC DATA; TIME ALIGNMENT; DATA SETS; TOOL; ANNOTATION; EXTRACTION; DECONVOLUTION;
D O I
10.1021/acs.analchem.7b03160
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-quality data analysis methodology remains a bottleneck for metabolic profiling analysis based on ultraperformance liquid chromatography-quadrupole time-Of-flight mass spectrometry. The present work aims to address this problem by proposing a novel data analysis strategy wherein (1) chromatographic peaks in the UPLC-QTOF data set are automatically extracted by using an advanced multiscale Gaussian smoothing-based peak extracHon strategy; (2) a peak annotation, stage is used to,cluster fragment ions that belong to the same compound. With the aid of high resolution mass spectrometer, (3) a time-shift correction across the samples is efficiently performed By a new peak alignment method; (4) components are registered by using a newly developed adaptive network searching algorithm; (5) statistical methods, such as analysis of variance and hierarchical cluster analysis, are then used to identify the underlying marker compounds; finally, (6) compound identification is performed by matching the extracted peak information, involving high-precision m/z and retention time, against our compound library containing more than 500 plant metabolites. A manually designed mixture of 18 compounds is used to evaluate the performance of the method, and all compounds are detected under various concentration levels. The developed method is comprehensively evaluated by an extremely complex plant data set containing more than 2000 components. Results indicate that the performance of the developed method is comparable with the XCMS. The MATLAB GUI code is available from http://software.tObaccodb.org/software/antdas.
引用
收藏
页码:11083 / 11090
页数:8
相关论文
共 45 条
[1]   BatMass: a Java']Java Software Platform for LC-MS Data Visualization in Proteomics and Metabolomics [J].
Avtonomov, Dmitry M. ;
Raskind, Alexander ;
Nesvizhskii, Alexey I. .
JOURNAL OF PROTEOME RESEARCH, 2016, 15 (08) :2500-2509
[2]   GlycoWorkbench: A tool for the computer-assisted annotation of mass spectra of Glycans [J].
Ceroni, Alessio ;
Maass, Kai ;
Geyer, Hildegard ;
Geyer, Rudolf ;
Dell, Anne ;
Haslam, Stuart M. .
JOURNAL OF PROTEOME RESEARCH, 2008, 7 (04) :1650-1659
[3]   Optimized time alignment algorithm for LC-MS data: Correlation optimized warping using component detection algorithm-selected mass chromatograms [J].
Christin, Christin ;
Smilde, Age K. ;
Hoefsloot, Huub C. J. ;
Suits, Frank ;
Bischoff, Rainer ;
Horvatovich, Peter L. .
ANALYTICAL CHEMISTRY, 2008, 80 (18) :7012-7021
[4]   Time Alignment Algorithms Based on Selected Mass Traces for Complex LC-MS Data [J].
Christin, Christin ;
Hoefsloot, Huub C. J. ;
Smilde, Age K. ;
Suits, Frank ;
Bischoff, Rainer ;
Horvatovich, Peter L. .
JOURNAL OF PROTEOME RESEARCH, 2010, 9 (03) :1483-1495
[5]   Alignment Using Variable Penalty Dynamic Time Warping [J].
Clifford, David ;
Stone, Glenn ;
Montoliu, Ivan ;
Rezzi, Serge ;
Martin, Francois-Pierre ;
Guy, Philippe ;
Bruce, Stephen ;
Kochhar, Sunil .
ANALYTICAL CHEMISTRY, 2009, 81 (03) :1000-1007
[6]   Improved peak detection in mass spectrum by incorporating continuous wavelet transform-based pattern matching [J].
Du, Pan ;
Kibbe, Warren A. ;
Lin, Simon M. .
BIOINFORMATICS, 2006, 22 (17) :2059-2065
[7]   Strategy for Optimizing LC-MS Data Processing in Metabolomics: A Design of Experiments Approach [J].
Eliasson, Mattias ;
Rannar, Stefan ;
Madsen, Rasmus ;
Donten, Magdalena A. ;
Marsden-Edwards, Emma ;
Moritz, Thomas ;
Shockcor, John P. ;
Johansson, Erik ;
Trygg, Johan .
ANALYTICAL CHEMISTRY, 2012, 84 (15) :6869-6876
[8]   Mass spectrometry in plant metabolomics strategies: from analytical platforms to data acquisition and processing [J].
Ernst, Madeleine ;
Silva, Denise Brentan ;
Silva, Ricardo Roberto ;
Vencio, Ricardo Z. N. ;
Lopes, Norberto Peporine .
NATURAL PRODUCT REPORTS, 2014, 31 (06) :784-806
[9]   Solutions for Low and High Accuracy Mass Spectrometric Data Matching: A Data-Driven Annotation Strategy in Nontargeted Metabolomics [J].
Forcisi, Sara ;
Moritz, Franco ;
Lucio, Marianna ;
Lehmann, Rainer ;
Stefan, Norbert ;
Schmitt-Kopplin, Philippe .
ANALYTICAL CHEMISTRY, 2015, 87 (17) :8917-8924
[10]   Wavelet-Based Peak Detection and a New Charge Inference Procedure for MS/MS Implemented in ProteoWizard's msConvert [J].
French, William R. ;
Zimmerman, Lisa J. ;
Schilling, Birgit ;
Gibson, Bradford W. ;
Miller, Christine A. ;
Townsend, R. Reid ;
Sherrod, Stacy D. ;
Goodwin, Cody R. ;
McLean, John A. ;
Tabb, David L. .
JOURNAL OF PROTEOME RESEARCH, 2015, 14 (02) :1299-1307