Modelling of detective quantum efficiency of direct conversion x-ray imaging detectors incorporating charge carrier trapping and K-fluorescence

被引:10
|
作者
Kabir, M. Z. [1 ]
Rahman, M. W. [1 ]
Shen, W. Y. [1 ]
机构
[1] Concordia Univ, Dept Elect & Comp Engn, Montreal, PQ H3G 1M8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ACTIVE-MATRIX READOUT; AMORPHOUS SELENIUM; DIGITAL FLUOROSCOPY; A-SE; RESOLUTION; PROTOTYPE; IMAGERS; SYSTEMS;
D O I
10.1049/iet-cds.2010.0338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A cascaded linear system model is developed for calculating the frequency-dependent detective quantum efficiency, DQE(f), of a direct conversion x-ray imaging detector by incorporating the effects of charge carrier trapping and reabsorption of K-fluorescent x-rays. The present model considers a combination of series and parallel processes and interactions between them. The modulation transfer function for K-fluorescent x-ray reabsorption is modelled by determining the line spread function and subsequent one-dimensional Fourier transform. The DQE model is applied to amorphous selenium (a-Se) and polycrystalline mercuric iodide (poly-HgI(2)) detectors. The charge carrier trapping has a significant effect on DQE in both a-Se and poly-HgI(2) detectors. The charge carrier transport properties have higher influences on DQE performance in a-Se detectors than that in HgI(2) detectors, because of relatively low conversion gain in a-Se detectors. High conversion gain can minimise the adverse effect of incomplete charge collection. A simplified model for the calculation of zero spatial frequency detective quantum efficiency, DQE(0), under parallel cascaded system is also proposed in this study. There exists an optimum photoconductor thickness, which maximises the DQE(0). The proposed model is compared with the published measured data and shows good agreement.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 50 条
  • [1] A detective quantum efficiency for spectroscopic X-ray imaging detectors
    Tanguay, Jesse
    Richtsmeier, Devon
    Dydula, Christopher
    Day, James A.
    Iniewski, Kris
    Bazalova-Carter, Magdalena
    MEDICAL PHYSICS, 2021, 48 (11) : 6781 - 6799
  • [2] Detective quantum efficiency of direct, flat panel x-ray imaging detectors for fluoroscopy
    Hunt, DC
    Zhao, W
    Rowlands, JA
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 408 - 417
  • [3] Impact of charge carrier trapping on amorphous selenium direct conversion avalanche X-ray detectors
    Arnab, Salman M.
    Kabir, M.Z.
    Journal of Applied Physics, 2017, 122 (13):
  • [4] Impact of charge carrier trapping on amorphous selenium direct conversion avalanche X-ray detectors
    Arnab, Salman M.
    Kabir, M. Z.
    JOURNAL OF APPLIED PHYSICS, 2017, 122 (13)
  • [5] Detective quantum efficiency of television X-ray detectors
    Kalata, Kenneth
    Stanton, Martin
    Phillips, Walter
    Journal of X-Ray Science and Technology, 1992, 3 (03)
  • [6] Detective quantum efficiency and Swank noise for spectroscopic X-ray imaging detectors
    Tanguay, Jesse
    Richtsmeier, Devon
    Dydula, Christopher
    Iniewski, Kris
    Bazalova-Carter, Magdalena
    MEDICAL PHYSICS, 2021, 48 (08) : 4668 - 4669
  • [7] Effect of depth dependent modulation transfer function and K-fluorescence reabsorption on the detective quantum efficiency of indirect conversion flat panel x-ray imaging systems using CsI
    Rowlands, JA
    Ji, WG
    Zhao, W
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 257 - 267
  • [8] Effects of charge carrier trapping on polycrystalline PbO x-ray imaging detectors
    Kabir, M. Z.
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (07)
  • [9] Direct conversion detectors: The effect of incomplete charge collection on detective quantum efficiency
    Mainprize, JG
    Hunt, DC
    Yaffe, MJ
    MEDICAL PHYSICS, 2002, 29 (06) : 976 - 990
  • [10] Detective quantum efficiency of photon-counting x-ray detectors
    Tanguay, Jesse
    Yun, Seungman
    Kim, Ho Kyung
    Cunningham, Ian A.
    MEDICAL PHYSICS, 2015, 42 (01) : 491 - 509