Effect of Oxygen Mole Fraction on Static Properties of Pressure-Sensitive Paint

被引:12
作者
Okudera, Tomohiro [1 ]
Nagata, Takayuki [1 ]
Kasai, Miku [1 ]
Saito, Yuji [1 ]
Nonomura, Taku [1 ]
Asai, Keisuke [1 ]
机构
[1] Tohoku Univ, Dept Aerosp Engn, Sendai, Miyagi 9808579, Japan
基金
日本学术振兴会;
关键词
pressure-sensitive paint; oxygen mole fraction; optimal condition;
D O I
10.3390/s21041062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effects of the oxygen mole fraction on the static properties of pressure-sensitive paint (PSP) were investigated. Sample coupon tests using a calibration chamber were conducted for poly(hexafluoroisopropyl methacrylate)-based PSP (PHFIPM-PSP), polymer/ceramic PSP (PC-PSP), and anodized aluminum PSP (AA-PSP). The oxygen mole fraction was set to 0.1-100%, and the ambient pressure (P-ref) was set to 0.5-140 kPa. Localized Stern-Volmer coefficient B-local increased and then decreased with increasing oxygen mole fraction. Although B-local depends on both ambient pressure and the oxygen mole fraction, its effect can be characterized as a function of the partial pressure of oxygen. For AA-PSP and PHFIPM-PSP, which are low-pressure- and relatively low-pressure-type PSPs, respectively, B-local peaks at PO2ref<12 kPa. In contrast, for PC-PSP, which is an atmospheric-pressure-type PSP in the investigated range, B-local does not have a peak. B-local has a peak at a relatively high partial pressure of oxygen due to the oxygen permeability of the polymer used in the binder. The peak of SPR, which is the emission intensity change with respect to normalized pressure fluctuation, appears at a lower partial pressure of oxygen than that of B-local. This is because the intensity of PSP becomes quite low at a high partial pressure of oxygen even if B-local is high. Hence, the optimal oxygen mole fraction depends on the type of PSP and the ambient pressure range of the experiment. This optimal value can be found on the basis of the partial pressure of oxygen.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 26 条
[1]   Pressure-sensitive paint technique for surface pressure measurements in a low-density wind tunnel [J].
Anyoji, M. ;
Numata, D. ;
Nagai, H. ;
Asai, K. .
JOURNAL OF VISUALIZATION, 2015, 18 (02) :297-309
[2]   Effects of Mach Number and Specific Heat Ratio on Low-Reynolds-Number Airfoil Flows [J].
Anyoji, Masayuki ;
Numata, Daiju ;
Nagai, Hiroki ;
Asai, Keisuke .
AIAA JOURNAL, 2015, 53 (06) :1640-1654
[3]   Novel pressure-sensitive paint for cryogenic and unsteady wind-tunnel testing [J].
Asai, K ;
Amao, Y ;
Iijima, Y ;
Okura, I ;
Nishide, H .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2002, 16 (01) :109-115
[4]   Surface pressure measurement in a cryogenic wind tunnel by luminescent coating [J].
Asai, K ;
Kanda, H ;
Cunningham, CT ;
Erausquin, R ;
Sullivan, JP .
ICIASF '97 RECORD - INTERNATIONAL CONGRESS ON INSTRUMENTATION IN AEROSPACE SIMULATION FACILITIES, 1997, :105-114
[5]  
Egami Y., 2012, P 44 AIAA AER SCI M, DOI [10.2514/6.2006-1045, DOI 10.2514/6.2006-1045]
[6]   Fast Pressure-Sensitive Paint for Flow and Acoustic Diagnostics [J].
Gregory, James W. ;
Sakaue, Hirotaka ;
Liu, Tianshu ;
Sullivan, John P. .
ANNUAL REVIEW OF FLUID MECHANICS, VOL 46, 2014, 46 :303-330
[7]   Finding Structure with Randomness: Probabilistic Algorithms for Constructing Approximate Matrix Decompositions [J].
Halko, N. ;
Martinsson, P. G. ;
Tropp, J. A. .
SIAM REVIEW, 2011, 53 (02) :217-288
[8]   The applications of pressure-sensitive paint in microfluidic systems [J].
Huang, Chih-Yung ;
Matsuda, Yu ;
Gregory, James W. ;
Nagai, Hiroki ;
Asai, Keisuke .
MICROFLUIDICS AND NANOFLUIDICS, 2015, 18 (5-6) :739-753
[9]  
Liu T., 2005, EXP FLUID MECH
[10]   Analysis of a civil aircraft wing transonic shock buffet experiment [J].
Masini, L. ;
Timme, S. ;
Peace, A. J. .
JOURNAL OF FLUID MECHANICS, 2020, 884