The possibility of using the maximum-entropy method in ultrasonic nondestructive testing for increasing the resolution of echo signals

被引:1
作者
Bazulin, A. E.
Bazulin, E. G.
机构
[1] Kurchatov Inst, Russian Res Ctr, Moscow 123182, Russia
[2] OOO Sci & Prod Ctr Ekho, Moscow 123182, Russia
关键词
Maximum Entropy; Nondestructive Test; Aluminum Specimen; Probe Angle; Echo Signal;
D O I
10.1134/S1061830906090014
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The problem of deconvoluting echo signals via regularization according to the maximum entropy method followed by the reconstruction of 2D images via the Fourier transformation synthetic aperture focusing technique (FT-SAFT) is considered. Numerical and experimental simulations have been performed. The possibility of improving the ray resolution of echo signals and reducing the speckle-noise level is demonstrated. The results obtained are compared to the results of constructing an AR model of the spectrum of echo signals.
引用
收藏
页码:559 / 577
页数:19
相关论文
共 47 条
[1]  
ABDELAAL RE, 1982, ACOUST IMAGING, V12, P679
[2]  
[Anonymous], METODY AKUSTICHESKOG
[3]  
[Anonymous], 1987, ACOUST IMAG
[4]  
Badalyan V. G., 1988, AKUST ZH, V34, P222
[5]  
BADALYAN VG, 1999, TEZ DOKL 15 ROSS NAU
[6]  
BADALYAN VG, 1993, DEFEKTKOSKOPIYA, P24
[7]  
BADALYAN VG, 2004, MIRE NERAZRUSH KONTR, P22
[8]  
BAZULIN AE, 2005, AKUST ZH, V51, P1
[9]  
Bazulin E.G., 1993, AKUST ZH, V39, P213
[10]  
BAZULIN EG, 1995, DEFEKTOSKOPIYA, P9