A Three-Dimensional Human Trunk Model for the Analysis of Respiratory Mechanics

被引:12
作者
Behr, Michel [1 ]
Peres, Jeremie [1 ]
Llari, Maxime [1 ]
Godio, Yves [1 ]
Jammes, Yves [2 ]
Brunet, Christian [1 ]
机构
[1] Univ Mediterranee, Fac Med Nord, LBA, INRETS,UMRT24, F-13916 Marseille, France
[2] Univ Mediterranee, Fac Med Nord, IFR Jean Roche, UMR MD2 P2COE, F-13916 Marseille, France
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2010年 / 132卷 / 01期
关键词
internal abdominal pressure; respiratory mechanics; diaphragm; numerical model; RIB CAGE; INTERCOSTAL MUSCLES; LOWER-EXTREMITY; LUNG-VOLUMES; DIAPHRAGM; RECONSTRUCTION; STIFFNESS;
D O I
10.1115/1.4000308
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Over the past decade, road safety research and impact biomechanics have strongly stimulated the development of anatomical human numerical models using the finite element (FE) approach. The good accuracy of these models, in terms of geometric definition and mechanical response, should now find new areas of application. We focus here on the use of such a model to investigate its potential when studying respiratory mechanics. The human body FE model used in this study was derived from the RADIOSS(R) HUMOS model. Modifications first concerned the integration and interfacing of a user-controlled respiratory muscular system including intercostal muscles, scalene muscles, the sternocleidomastoid muscle, and the diaphragm and abdominal wall muscles. Volumetric and pressure measurement procedures for the lungs and both the thoracic and abdominal chambers were also implemented. Validation of the respiratory module was assessed by comparing a simulated maximum inspiration maneuver to volunteer studies in the literature. Validation parameters included lung volume changes, rib rotations, diaphragm shape and vertical deflexion, and infra-abdominal pressure variation. The HUMOS model, initially dedicated to road safety research, could be turned into a promising, realistic 3D model of respiration with only minor modifications. [DOI: 10.1115/1.4000308]
引用
收藏
页数:4
相关论文
共 27 条
[1]  
Behr M., 2003, Computer Methods in Biomechanics and Biomedical Engineering, V6, P263, DOI 10.1080/10255840310001606080
[2]   3D reconstruction of the diaphragm for virtual traumatology [J].
Behr, Michel ;
Thollon, Lionel ;
Arnoux, Pierre-Jean ;
Serre, Thierry ;
Berdah, Stephane Victor ;
Baque, Patrick ;
Brunet, Christian .
SURGICAL AND RADIOLOGIC ANATOMY, 2006, 28 (03) :235-240
[3]   Sex differences in thoracic dimensions and configuration [J].
Bellemare, F ;
Jeanneret, A ;
Couture, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2003, 168 (03) :305-312
[4]   Anatomic landmarks to estimate the length of the diaphragm from chest radiographs - Effects of emphysema and lung volume reduction surgery [J].
Bellemare, F ;
Couture, J ;
Cordeau, MP ;
Leblanc, F ;
Lafontaine, E .
CHEST, 2001, 120 (02) :444-452
[5]   Diaphragm and chest wall: Assessment of the inspiratory pump with MR imaging - Preliminary observations [J].
Cluzel, P ;
Similowski, T ;
Chartrand-Lefebvre, C ;
Zelter, M ;
Derenne, JP ;
Grenier, PA .
RADIOLOGY, 2000, 215 (02) :574-583
[6]   Static lung volumes: Reference values from a Latin population of Spanish descent [J].
Cordero, PJ ;
Morales, P ;
Benlloch, E ;
Miravet, L ;
Cebrian, J .
RESPIRATION, 1999, 66 (03) :242-250
[7]   AN INTERACTIVE GRAPHICS-BASED MODEL OF THE LOWER-EXTREMITY TO STUDY ORTHOPEDIC SURGICAL-PROCEDURES [J].
DELP, SL ;
LOAN, JP ;
HOY, MG ;
ZAJAC, FE ;
TOPP, EL ;
ROSEN, JM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (08) :757-767
[8]   CONTRACTILE PROPERTIES OF INTERCOSTAL MUSCLES AND THEIR FUNCTIONAL-SIGNIFICANCE [J].
FARKAS, GA ;
DECRAMER, M ;
ROCHESTER, DF ;
DETROYER, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (02) :528-535
[9]   3-DIMENSIONAL RECONSTRUCTION OF THE IN-VIVO HUMAN DIAPHRAGM SHAPE AT DIFFERENT LUNG-VOLUMES [J].
GAUTHIER, AP ;
VERBANCK, S ;
ESTENNE, M ;
SEGEBARTH, C ;
MACKLEM, PT ;
PAIVA, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (02) :495-506
[10]   Human muscle hardness assessment during incremental isometric contraction using transient elastography [J].
Gennisson, JL ;
Cornu, C ;
Catheline, S ;
Fink, M ;
Portero, P .