Determination of Manganese in Cassava Leaves by Slurry Sampling Flame Atomic Absorption Spectrometry

被引:13
作者
Dias, Fabio de Souza [1 ,2 ]
Alves, Lucylia Suzart
dos Santos, Walter Nei L. [3 ]
David, Jorge Mauricio [2 ]
Ferreira, Sergio Luis C. [2 ]
机构
[1] Univ Fed Reconcavo Bahia, Ctr Ciencias Exatas & Tecnol, LAIA, BR-44380000 Cruas Das Almas, BA, Brazil
[2] Univ Fed Bahia, Inst Quim, Salvador, BA, Brazil
[3] Univ Estado Bahia, Dept Ciencias Exatas & Terra, Salvador, BA, Brazil
关键词
Cassava leaves; FAAS; manganese; slurry; PLASMA-MASS SPECTROMETRY; SILICON-CARBIDE; LEAD; PB; CD; NEBULIZATION; IMPURITIES; COAL;
D O I
10.1080/00032710903137368
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cassava, Manihot esculenta crantz, constitutes one of the main foods consumed by most of the population of developing countries, mainly in the population of low income. It is largely used for its low cost and the diversity of its root and leaves products. In this paper, a slurry sampling flame atomic absorption spectrometric method for the determination of manganese in cassava leaves is proposed. The slurry sampling was used in order to shorten the analysis time and to minimize the problems associated with solid sample treatment such as wet acid digestion, dry-ashing, sample contamination, and analyte loss. The samples of cassava leaves were washed with extran 10% (v/v), soon afterwards they were dried in an oven to 60 degrees C, triturated in a mill of spheres, and the obtained material was sifted in a mesh of 100 micrometers. Then 0.1 g of the sample was weighed in a balloons volumetric flask, the volume was completed with 25 mL of acid nitric 2,0 mol L-1, and followed by 20 minutes in an ultrasonic bath and subsequent reading in FAAS. The analyses of the certified reference material of spinach and apple leaves evidenced the accuracy of the method. The proposed method was applied for the determination of manganese in four samples of cassava leaves acquired in markets from Feira de Santana City, Brazil. The concentration of manganese found in cassava leaves varied from 202.7 to 181.3 mu g g(-1), with detection and quantification limits of 0.17 and 0.56 mu g g(-1), respectively. The precision expressed as relative standard deviation (RSD) was 1.7 and 3.2% (n = 10) for 100 and 12 mu g g(-1), respectively.
引用
收藏
页码:2206 / 2213
页数:8
相关论文
共 23 条
[1]  
ANZANO JM, 2006, J FOOD COMPOS ANAL, V13, P837
[2]   Method development for the determination of manganese in wheat flour by slurry sampling flame atomic absorption spectrometry [J].
Araujo, Rennan G. O. ;
Dias, Fabio De S. ;
Macedo, Samuel M. ;
dos Santos, Walter N. L. ;
Ferreira, Sergio L. C. .
FOOD CHEMISTRY, 2007, 101 (01) :397-400
[3]  
AZEVEDO FA, 2003, METAIS GERENCIAMENTO, P74
[4]   THE MATRIX MODIFICATION OF BORON AND ITS DETERMINATION BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY SLURRY ATOMIZATION USING TOTALLY PYROLYTIC-GRAPHITE TUBES [J].
BARNETT, N ;
EBDON, L ;
EVANS, EH ;
OLLIVIER, P .
MICROCHEMICAL JOURNAL, 1991, 44 (02) :168-178
[5]   Feasibility of employing permanent chemical modifiers for the determination of cadmium in coal using slurry sampling electrothermal atomic absorption spectrometry [J].
Bianchin, L ;
Nadvorny, D ;
da Silva, AF ;
Vale, MGR ;
da Silva, MM ;
dos Santos, WNL ;
Ferreira, SLC ;
Welz, B ;
Heitmann, U .
MICROCHEMICAL JOURNAL, 2006, 82 (02) :174-182
[6]   DETERMINATION OF IMPURITIES IN SILICON-CARBIDE POWDERS [J].
DOCEKAL, B ;
BROEKAERT, JAC ;
GRAULE, T ;
TSCHOPEL, P ;
TOLG, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2) :113-117
[7]   Slurry nebulization in plasmas [J].
Ebdon, L ;
Foulkes, M ;
Sutton, K .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) :213-229
[8]   Trace element risk assessment: essentiality vs. toxicity [J].
Goldhaber, SB .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2003, 38 (02) :232-242
[9]   Application of the slurry technique to the determination of selenium in fish samples by electrothermal atomic absorption spectrometry [J].
Januzzi, GSB ;
Krug, FJ ;
Arruda, MAZ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :375-378
[10]  
Kurfurst U., 1997, SOLID SAMPLE ANAL DI