Measurement of coronary blood flow and flow reserve using magnetic resonance imaging

被引:30
|
作者
Grist, TM
Polzin, JA
Bianco, JA
Foo, TKF
Bernstein, MA
Mistretta, CM
机构
[1] UNIV WISCONSIN,SCH MED,DEPT RADIOL,MADISON,WI
[2] UNIV WISCONSIN,SCH MED,DEPT CARDIOL,MADISON,WI
[3] UNIV WISCONSIN,SCH MED,DEPT MED PHYS,MADISON,WI
[4] GEN ELECT MED SYST,MILWAUKEE,WI
关键词
magnetic resonance; coronary blood flow;
D O I
10.1159/000177314
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: It was the purpose of this study to demonstrate the feasibility of performing coronary artery flow and coronary flow reserve (CFR) measurements in normal human volunteers using a magnetic resonance (MR) phase contrast technique. Materials and Methods: Coronary flow rate, flow velocity, peak flow and CFR were determined at rest and during pharmacologically induced hyperemia in 10 healthy volunteers, The flow measurements were obtained during a single breath-hold by using a fast, prospectively gated, segmented k-space gradient-echo phase contrast acquisition with view sharing (FASTCARD PC) that was modified to improve sampling of the diastolic flow. Data were processed using the standard phase difference (PD) processing techniques as well as a new complex difference (CD) flow measurement method intended to improve the accuracy of flow measurements in small vessels. Results: Mean hyperemic flow velocity (40 +/- 16 cm/s) and blood flow (3.9 +/- 1.5 ml/s) rates differed significantly from resting velocity (13 +/- 6.6 cm/s) and flow (1.1 +/- 0.4 ml/s) measurements (p < 0.0001), PD methods consistently measured larger flow rates at rest (24% larger, p < 0.0005) and stress (29% larger, p < 0.0001), CFR, calculated as the ratio of the mean PD flows (4.7 +/- 2.8), was higher than CFR calculated as the ratio of mean CD flows (4.2 +/- 1.8); however, the differences did not reach statistical significance (p = 0.07). Flow measurements performed in adjacent slices of the same vessel correlated well (r = 0.88). Conclusions: Coronary flow and CFR measurements using the MR techniques are feasible and are similar to those reported in the literature for healthy volunteers.
引用
收藏
页码:80 / 89
页数:10
相关论文
共 50 条
  • [31] VISUALIZATION OF CORONARY ANATOMY AND BLOOD-FLOW BY MAGNETIC-RESONANCE IMAGING
    OHNISHI, S
    FUKUI, S
    ATSUMI, C
    MORITA, R
    FUJII, K
    KUSUOKA, H
    KITABATAKE, A
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1988, 52 (08): : 869 - 870
  • [32] MEASUREMENT OF CORONARY-ARTERY FLOW RESERVE BY MAGNETIC-RESONANCE VELOCITY MAPPING IN THE AORTA
    BOGREN, HG
    BUONOCORE, MH
    LANCET, 1993, 342 (8876): : 899 - 900
  • [33] Coronary Flow Reserve by Cardiac Magnetic Resonance Imaging in Patients With Ischemic Cardiomyopathy With Diabetes Mellitus
    Kato, Shingo
    Fukui, Kazuki
    Kodama, Sho
    Hayakawa, Keigo
    Azuma, Mai
    Kagimoto, Minako
    Iguchi, Kohei
    Fukuoka, Masahiro
    Iwasawa, Tae
    Utsunomiya, Daisuke
    Kosuge, Masami
    Kimura, Kazuo
    Tamura, Kouichi
    CIRCULATION, 2019, 140
  • [34] Prognostic Significance of Magnetic Resonance Imaging Derived Coronary Flow Reserve for Heart Failure Patients
    Kato, Shingo
    Asahina, Naoki
    Iinuma, Naoki
    Kusakawa, Yuka
    Minegishi, Shintaro
    Kamimura, Daisuke
    Nakachi, Tatsuya
    Fukui, Kazuki
    Kosuge, Masami
    Kimura, Kazuo
    Tamura, Kouichi
    CIRCULATION, 2017, 136
  • [35] Prognostic value of magnetic resonance imaging derived coronary flow reserve for patients with diabetes mellitus
    Kato, S.
    Saito, N.
    Asahina, N.
    Iinuma, N.
    Kamimura, D.
    Nakachi, T.
    Fukui, K.
    Iwasawa, T.
    Kosuge, M.
    Kimura, K.
    Tamura, K.
    EUROPEAN HEART JOURNAL, 2018, 39 : 630 - 630
  • [36] THE MEASUREMENT AND VISUALIZATION OF VESSEL BLOOD-FLOW BY MAGNETIC-RESONANCE-IMAGING
    SMITH, MA
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (02): : 101 - 123
  • [37] MAGNETIC-RESONANCE TECHNIQUES FOR BLOOD-FLOW MEASUREMENT AND VASCULAR IMAGING
    RUTT, BK
    NAPEL, S
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1991, 42 (01): : 21 - 30
  • [38] MEASUREMENT OF STROKE VOLUME USING MAGNETIC-RESONANCE FLOW IMAGING
    MATSUDA, T
    NAGANO, Y
    HASHIMOTO, S
    SAKURAI, T
    KAWAI, C
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1987, 51 (08): : 890 - 891
  • [39] Measurement of an oil-water flow using magnetic resonance imaging
    Lakshmanan, Susithra
    Maru, Wessenu A.
    Holland, Daniel J.
    Mantle, Mick D.
    Sederman, Andy J.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 53 : 161 - 171
  • [40] Regional myocardial perfusion reserve determined using myocardial perfusion magnetic resonance imaging showed a direct correlation with coronary flow velocity reserve by Doppler flow wire
    Kurita, Tairo
    Sakuma, Hajime
    Onishi, Katsuya
    Ishida, Masaki
    Kitagawa, Kakuya
    Yamanaka, Takashi
    Tanigawa, Takashi
    Kitamura, Tetsuya
    Takeda, Kan
    Ito, Masaaki
    EUROPEAN HEART JOURNAL, 2009, 30 (04) : 444 - 452