Optimization of oncological 18F-FDG PET/CT imaging based on a multiparameter analysis

被引:13
|
作者
Menezes, Vinicius O. [1 ,2 ]
Machado, Marcos A. D. [1 ,3 ]
Queiroz, Cleiton C. [1 ,4 ]
Souza, Susana O. [5 ]
d'Errico, Francesco [6 ,7 ]
Namias, Mauro [8 ]
Larocca, Ticiana F. [9 ]
Soares, Milena B. P. [9 ,10 ]
机构
[1] Sao Rafael Hosp, Dept Nucl Med, BR-41720375 Salvador, BA, Brazil
[2] Univ Fed Pernambuco Ebserh, Dept Nucl Med, Hosp Clin, BR-50670901 Recife, PE, Brazil
[3] Univ Fed Bahia Ebserh, Dept Nucl Med, Hosp Clin, BR-40110060 Salvador, BA, Brazil
[4] Univ Hosp, Dept Nucl Med, BR-57072900 Maceio, Brazil
[5] Univ Fed Sergipe, Dept Phys, BR-49100000 Sao Cristovao, Brazil
[6] Yale Univ, Sch Med, Dept Diagnost Radiol, New Haven, CT 06520 USA
[7] Univ Pisa, Sch Engn, I-56126 Pisa, Italy
[8] Fdn Ctr Diagnost Nucl, C1417CVE, Buenos Aires, DF, Argentina
[9] Sao Rafael Hosp, Ctr Biotecnol & Terapia Celular, BR-41253190 Salvador, BA, Brazil
[10] Fundacao Oswaldo Cruz, Ctr Pesq Goncalo Moniz, BR-40296710 Salvador, BA, Brazil
关键词
PET/CT; optimization; image quality consistency; low dose; F-18-FDG; POINT-SPREAD FUNCTION; WHOLE-BODY PET; TIME-OF-FLIGHT; FDG-PET/CT; NOISE; RECONSTRUCTION; WEIGHT; SCANNER; SIGNAL; SIZE;
D O I
10.1118/1.4940354
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This paper describes a method to achieve consistent clinical image quality in 18F-FDG scans accounting for patient habitus, dose regimen, image acquisition, and processing techniques. Methods: Oncological PET/CT scan data for 58 subjects were evaluated retrospectively to derive analytical curves that predict image quality. Patient noise equivalent count rate and coefficient of variation (CV) were used as metrics in their analysis. Optimized acquisition protocols were identified and prospectively applied to 179 subjects. Results: The adoption of different schemes for three body mass ranges (<60 kg, 60-90 kg, >90 kg) allows improved image quality with both point spread function and ordered-subsets expectation maximization-3D reconstruction methods. The application of this methodology showed that CV improved significantly (p < 0.0001) in clinical practice. Conclusions: Consistent oncological PET/CT image quality on a high-performance scanner was achieved from an analysis of the relations existing between dose regimen, patient habitus, acquisition, and processing techniques. The proposed methodology may be used by PET/CT centers to develop protocols to standardize PET/CT imaging procedures and achieve better patient management and cost-effective operations. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:930 / 938
页数:9
相关论文
共 50 条
  • [1] 18F-FDG PET/CT Imaging Findings of Leprosy
    Shao, Dan
    Deng, Yue-Ting
    Shao, Fu-Qiang
    Liang, Jia-Wei
    Wang, Shu-Xia
    CLINICAL NUCLEAR MEDICINE, 2020, 45 (05) : E236 - E238
  • [2] Pulmonary Carcinosarcoma: 18F-FDG PET/CT Imaging
    Chuang, Tzyy-Ling
    Lai, Chun-Liang
    Chang, Shu-Mei
    Wang, Yuh-Feng
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (11) : 1105 - 1107
  • [3] Imaging of Acute and Chronic Aortic Dissection by 18F-FDG PET/CT
    Reeps, Christian
    Pelisek, Jaroslav
    Bundschuh, Ralph A.
    Gurdan, Manuela
    Zimmermann, Alexander
    Ockert, Stefan
    Dobritz, Martin
    Eckstein, Hans-Henning
    Essler, Markus
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (05) : 686 - 691
  • [4] Hepatic Schwannoma on 18F-FDG PET/CT
    Liu, Yachao
    Xu, Baixuan
    CLINICAL NUCLEAR MEDICINE, 2020, 45 (10) : 808 - 810
  • [5] Diagnostic Value of 18F-FDG PET/CT in Comparison to Bone Scintigraphy, CT and 18F-FDG PET for the Detection of Bone Metastasis
    Liu, Ning-Bo
    Zhu, Lei
    Li, Ming-Huan
    Sun, Xiao-Rong
    Hu, Man
    Huo, Zong-Wei
    Xu, Wen-Gui
    Yu, Jin-Ming
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2013, 14 (06) : 3647 - 3652
  • [6] Thoracic Staging in Lung Cancer: Prospective Comparison of 18F-FDG PET/MR Imaging and 18F-FDG PET/CT
    Heusch, Philipp
    Buchbender, Christian
    Koehler, Jens
    Nensa, Felix
    Gauler, Thomas
    Gomez, Benedikt
    Reiss, Henning
    Stamatis, Georgios
    Kuehl, Hilmar
    Hartung, Verena
    Heusner, Till A.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (03) : 373 - 378
  • [7] Prospective comparison of combined 18F-FDG and 18F-NaF PET/CT vs. 18F-FDG PET/CT imaging for detection of malignancy
    Lin, Frank I.
    Rao, Jyotsna E.
    Mittra, Erik S.
    Nallapareddy, Kavitha
    Chengapa, Alka
    Dick, David W.
    Gambhir, Sanjiv Sam
    Iagaru, Andrei
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (02) : 262 - 270
  • [8] 18F-FDG PET/CT Imaging of Tracheal Mucoepidermoid Carcinoma
    Jiang, Lei
    Huang, Yan
    Huang, Shanshan
    Li, Qiang
    Wang, Huoqiang
    CLINICAL NUCLEAR MEDICINE, 2017, 42 (11) : 874 - 875
  • [9] 18F-FDG PET/CT imaging features of lipomatous tumors
    Baffour, Francis, I
    Wenger, Doris E.
    Broski, Stephen M.
    AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 10 (01): : 74 - 82
  • [10] Quantifying tumour heterogeneity in 18F-FDG PET/CT imaging by texture analysis
    Sugama Chicklore
    Vicky Goh
    Musib Siddique
    Arunabha Roy
    Paul K. Marsden
    Gary J. R. Cook
    European Journal of Nuclear Medicine and Molecular Imaging, 2013, 40 : 133 - 140