Spinal pedicle screw planning using deformable atlas registration

被引:37
作者
Goerres, J. [1 ]
Uneri, A. [1 ]
De Silva, T. [1 ]
Ketcha, M. [1 ]
Reaungamornrat, S. [1 ]
Jacobson, M. [1 ]
Vogt, S. [2 ]
Kleinszig, G. [2 ]
Osgood, G. [3 ]
Wolinsky, J-P [4 ]
Siewerdsen, J. H. [1 ]
机构
[1] Johns Hopkins Univ, Biomed Engn, Baltimore, MD 21218 USA
[2] Siemens, Healthineers XP, Erlangen, Germany
[3] Johns Hopkins Univ Hosp, Dept Orthopaed Surg, Baltimore, MD USA
[4] Johns Hopkins Univ Hosp, Dept Neurosurg, Baltimore, MD 21287 USA
关键词
atlas registration; pedicle screw; image-guided surgery; quality assurance; surgical guidance; spine surgery; automatic planning; CONE-BEAM CT; SEGMENTATION; GUIDANCE; PLACEMENT; ARM; ACCURACY; QUALITY; MODELS; IMAGES; MOBILE;
D O I
10.1088/1361-6560/aa5f42
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Spinal screw placement is a challenging task due to small bone corridors and high risk of neurological or vascular complications, benefiting from precision guidance/navigation and quality assurance (QA). Implicit to both guidance and QA is the definition of a surgical plan-i.e. the desired trajectories and device selection for target vertebrae-conventionally requiring timeconsuming manual annotations by a skilled surgeon. We propose automation of such planning by deriving the pedicle trajectory and device selection from a patient's preoperative CT or MRI. An atlas of vertebrae surfaces was created to provide the underlying basis for automatic planning-in this work, comprising 40 exemplary vertebrae at three levels of the spine (T7, T8, and L3). The atlas was enriched with ideal trajectory annotations for 60 pedicles in total. To define trajectories for a given patient, sparse deformation fields from the atlas surfaces to the input (CT or MR image) are applied on the annotated trajectories. Mean value coordinates are used to interpolate dense deformation fields. The pose of a straight trajectory is optimized by image-based registration to an accumulated volume of the deformed annotations. For evaluation, input deformation fields were created using coherent point drift (CPD) to perform a leave-one-out analysis over the atlas surfaces. CPD registration demonstrated surface error of 0.89 +/- 0.10 mm ( median +/- interquartile range) for T7/T8 and 1.29 +/- 0.15 mm for L3. At the pedicle center, registered trajectories deviated from the expert reference by 0.56 +/- 0.63 mm ( T7/T8) and 1.12 +/- 0.67 mm (L3). The predicted maximum screw diameter differed by 0.45 +/- 0.62 mm ( T7/T8), and 1.26 +/- 1.19 mm ( L3). The automated planning method avoided screw collisions in all cases and demonstrated close agreement overall with expert reference plans, offering a potentially valuable tool in support of surgical guidance and QA.
引用
收藏
页码:2871 / 2891
页数:21
相关论文
共 46 条
[1]   Lumbar pedicle: surgical anatomic evaluation and relationships [J].
Attar, A ;
Ugur, HC ;
Uz, A ;
Tekdemir, I ;
Egemen, N ;
Genc, Y .
EUROPEAN SPINE JOURNAL, 2001, 10 (01) :10-15
[2]   Statistical Interspace Models (SIMs): Application to Robust 3D Spine Segmentation [J].
Castro-Mateos, Isaac ;
Pozo, Jose M. ;
Pereanez, Marco ;
Lekadir, Karim ;
Lazary, Aron ;
Frangi, Alejandro F. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (08) :1663-1675
[3]  
Chintalapani G, 2007, LECT NOTES COMPUT SC, V4791, P499
[4]  
Chip Routt M., 1993, Operat Tech Orthop, V3, P35, DOI [DOI 10.1016/S1048-6666(06)80007-8, 10.1016/S1048-6666(06)80007-8]
[5]  
Daemi N, 2015, IEEE ENG MED BIO, P3639, DOI 10.1109/EMBC.2015.7319181
[6]   Fast Generation of Virtual X-ray Images for Reconstruction of 3D Anatomy [J].
Ehlke, Moritz ;
Ramm, Heiko ;
Lamecker, Hans ;
Hege, Hans-Christian ;
Zachow, Stefan .
IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2013, 19 (12) :2673-2682
[7]   Articular surface segmentation using active shape models for intraoperative implant assessment [J].
Goerres, Joseph ;
Brehler, Michael ;
Franke, Jochen ;
Vetter, Sven Y. ;
Gruetzner, Paul A. ;
Meinzer, Hans-Peter ;
Wolf, Ivo .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (09) :1661-1672
[8]   Intraoperative detection and localization of cylindrical implants in cone-beam CT image data [J].
Goerres, Joseph ;
Brehler, Michael ;
Franke, Jochen ;
Barth, Karl ;
Vetter, Sven Y. ;
Cordova, Andres ;
Gruetzner, Paul A. ;
Meinzer, Hans-Peter ;
Wolf, Ivo ;
Nabers, Diana .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (06) :1045-1057
[9]   Learning-Based Vertebra Detection and Iterative Normalized-Cut Segmentation for Spinal MRI [J].
Huang, Szu-Hao ;
Chu, Yi-Hong ;
Lai, Shang-Hong ;
Novak, Carol L. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (10) :1595-1605
[10]  
Ibragimov B, 2015, LECT NOTES COMPUTATI, P73