Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty

被引:67
作者
Gomi, Tsutomu [1 ]
Hirano, Hiroshi [2 ]
机构
[1] Kitasato Univ, Sch Allied Hlth Sci, Kanagawa 2288555, Japan
[2] Shinshu Univ Hosp, Dept Radiol, Nagano 3908621, Japan
关键词
digital tomosynthesis; total joint arthroplasty;
D O I
10.1007/s10278-007-9040-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The present study was performed to evaluate the potential for clinical application of digital linear tomosynthesis in imaging hip prostheses. Volumetric x-ray digital linear tomosysnthesis was used to image hip prostheses. The tomosynthesis was compared to metal artifact reduction (MAR) computed tomography (CT), and non-MAR CT scans of a prosthesis case. The effectiveness of this method in enhancing visibility of a prosthesis case was quantified in terms of the signal-to-noise ratio (SNR), and removal of ghosting artifacts in a prosthesis case was quantified in terms of the artifact spread function (ASF). In the near in-focus plane, the contrast is greater in the MAR CT or tomosynthesis relative to the non-MAR CT. The order of ASF performance of the algorithm was as follows: (1) tomosynthesis; (2) MAR-CT; (3) non-MAR CT. The potential usefulness of digital linear tomosynthesis for evaluation of hip prostheses was demonstrated. Further studies are required to determine the ability of digital linear tomosynthesis to quantify the spatial relationships between the metallic components of these devices as well as to identify bony changes with diagnostic consequences.
引用
收藏
页码:312 / 322
页数:11
相关论文
共 35 条
[1]  
Badea C, 2001, MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, P739
[2]   Image quality in extended arc filtered digital tomosynthesis [J].
Badea, C ;
Kolitsi, Z ;
Pallikarakis, N .
ACTA RADIOLOGICA, 2001, 42 (02) :244-248
[3]   An adapted fan volume sampling scheme for 3-D algebraic reconstruction in linear tomosynthesis [J].
Bleuet, P ;
Guillemaud, R ;
Desbat, L ;
Magnin, I .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2366-2372
[4]   Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm [J].
De Man, B ;
Nuyts, J ;
Dupont, P ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :977-981
[5]  
des Plantes BGZ, 1932, ACTA RADIOL, V13, P182
[6]   Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106
[7]   Digital tomosynthesis of hand joints for arthritis assessment [J].
Duryea, J ;
Dobbins, JT ;
Lynch, JA .
MEDICAL PHYSICS, 2003, 30 (03) :325-333
[8]   ECTOMOGRAPHY - A NEW RADIOGRAPHIC METHOD FOR REPRODUCING A SELECTED SLICE OF VARYING THICKNESS [J].
EDHOLM, P ;
GRANLUND, G ;
KNUTSSON, H ;
PETERSSON, C .
ACTA RADIOLOGICA-DIAGNOSIS, 1980, 21 (04) :433-442
[9]   AN EXPERIMENTAL-STUDY OF NEW DIAGNOSTIC METHODS FOR THE EXAMINATION OF OSSEOUS LESIONS IN THE TEMPOROMANDIBULAR-JOINT [J].
ENGELKE, W ;
RUTTIMANN, UE ;
TSUCHIMOCHI, M ;
BACHER, JD .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 73 (03) :348-359
[10]  
GOMI T, 2007, DENTOMAXILL IN PRESS