Comparative Life Cycle Assessment of a Thai Island's diesel/PV/wind hybrid microgrid

被引:73
作者
Smith, Cameron [1 ,3 ]
Burrows, John [1 ,3 ]
Scheier, Eric [1 ,3 ]
Young, Amberli [1 ,3 ]
Smith, Jessica [1 ,3 ]
Young, Tiffany [1 ,3 ]
Gheewala, Shabbir H. [2 ,3 ,4 ]
机构
[1] Univ N Carolina, Inst Environm, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Gillings Sch Publ Hlth, Dept Environm Sci & Engn, Chapel Hill, NC 27599 USA
[3] King Mongkuts Univ Technol Thonburi, Joint Grad Sch Energy & Environm, Bangkok 10140, Thailand
[4] Minist Educ, Ctr Energy Technol & Environm, Thailand, Thailand
关键词
Hybrid microgrid system; Life Cycle Assessment; Rural electrification development; Power grid extension; Renewable energy; Diesel electricity generation; RURAL ELECTRIFICATION;
D O I
10.1016/j.renene.2015.01.003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hybrid microgrid systems are an emerging tool for rural electrification due in part to their purported environmental benefits. This study uses Life Cycle Assessment (LCA) to compare the environmental impacts of a diesel/PV/wind hybrid microgrid on the island of Koh Jig, Thailand with the electrification alternatives of grid extension and home diesel generators. The impact categories evaluated are: acidification potential (kg SO2 eq), global warming potential (kg CO2 eq), human toxicity potential (kg 1.4 DCB eq), and abiotic resource depletion potential (kg Sb eq). The results show that the microgrid system has the lowest global warming and abiotic resource depletion potentials of all three electrification scenarios. The use phase of the diesel generator and the extraction of copper are shown to significantly contribute to the microgrid's environmental impacts. The relative environmental impacts of the grid extension scenario are found to be proportional to the distance required for grid extension. Across all categories except acidification potential, the impacts from the home diesel generators are the largest. Sensitivity analyses show that maximizing the renewable energy fraction does not necessarily produce a more environmentally sustainable electrification scenario and that the diesel generator provides versatility to the system by allowing power production to be scaled significantly before more technology is needed to meet demand. While the environmental benefits of the microgrid increase as the installation community becomes more isolated, the choice of electrification scenario requires assigning relative importance to each impact category and considering social and economic factors. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:85 / 100
页数:16
相关论文
共 21 条
[1]  
[Anonymous], 2011, 2794 MSDS UN
[2]  
[Anonymous], 2006, ISO 14040 2006 ENV M
[3]  
[Anonymous], 2011, World Energy Outlook 2011
[4]   Optimal design of a PV-diesel hybrid system for electrification of an isolated island-Sandwip in Bangladesh using genetic algorithm [J].
Bala, B. K. ;
Siddique, Saiful Azam .
ENERGY FOR SUSTAINABLE DEVELOPMENT, 2009, 13 (03) :137-142
[5]  
Chaisakomsamut Sahas, COMMUNICATION
[6]   Assessment and evaluation of PV based decentralized rural electrification: An overview [J].
Chaurey, Akanksha ;
Kandpal, Tara Chandra .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (08) :2266-2278
[7]  
Chris Greacen, 2007, RENEWABLE ENERGY OPT
[8]   Infrastructure, rural electrification and development [J].
Cook, Paul .
ENERGY FOR SUSTAINABLE DEVELOPMENT, 2011, 15 (03) :304-313
[9]   An empirical analysis of the impact of renewable energy deployment on local sustainability [J].
del Rio, Pablo ;
Burguillo, Mercedes .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (6-7) :1314-1325
[10]   Photovoltaics: Life-cycle analyses [J].
Fthenakis, V. M. ;
Kim, H. C. .
SOLAR ENERGY, 2011, 85 (08) :1609-1628