共 50 条
Organic-free, versatile sessile droplet microfluidic device for chemical separation using an aqueous two-phase system
被引:22
作者:
Hermann, Matthias
[1
]
Agrawal, Prashant
[1
]
Koch, Iris
[2
]
Oleschuk, Richard
[1
]
机构:
[1] Queens Univ, Dept Chem, 90 Bader Lane, Kingston, ON K7L 3N6, Canada
[2] Royal Mil Coll Canada, Environm Sci Grp, 12 Verite Ave, Kingston, ON K7K 5P2, Canada
基金:
加拿大自然科学与工程研究理事会;
关键词:
METAL-IONS;
HYDROPHOBIC RECOVERY;
EXTRACTION BEHAVIOR;
CADMIUM;
LAB;
PARTITION;
FUTURE;
SALT;
SOIL;
D O I:
10.1039/c8lc01121d
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
This work presents a novel portable, versatile sessile droplet microfluidic (SDMF) device to perform liquid manipulation operations such as confining, splitting and colorimetric detection. Furthermore, chemical isolations based on an aqueous two-phase system (ATPS) for separating an analyte of choice from a complicated sample matrix can be carried out. ATPS extractions can replace conventional liquid-liquid extractions and take away the need for harmful organic solvents. Superhydrophobic (SH) surfaces were fabricated from a commercially available material, Ultra-Ever Dry (R) (UED (R)). On these SH surfaces, surface energy traps (SETs) were produced either by air plasma treatment (simultaneously) or laser micromachining (sequentially) to dock/pin an ATPS containing droplet onto the surface. Splitting of droplets or removing a precise volume of the top phase from a pinned extraction system was achieved with a sandwich-chip approach. For this, an additional SET patterned substrate was placed on top of the droplet and subsequently lifted. This multipurpose platform was used to isolate Cd from a mixture of several other metal ions (i.e. Mn, Ni, Cu, Pb, Fe) for its subsequent interference-free detection. An ATPS consisting of sodium sulfate and polyethylene glycol (PEG) as phase forming components and potassium iodine as extractant allowed separation of cadmium with an extraction efficiency of q(Cd2+) = 98.5%. Using a portable, cost-effective, smartphone-based UV/vis spectrometer, Cd was detected with a LoD of 3.4 ppm. Alternatively, the multipurpose platform can also be used as sampling platform for a benchtop UV/vis spectrometer, where a LoD of 0.53 ppm was obtained. Potential applications of the presented platform include sample preparation and separation that can be achieved by aqueous two-phase extractions, such as proteins, antibodies, DNA, cells, organic molecules and metal ions.
引用
收藏
页码:654 / 664
页数:11
相关论文