Interobserver reliability of neck-mobility measurement by means of the flock-of-birds electromagnetic tracking system

被引:28
作者
Assink, N
Bergman, GJD
Knoester, B
Winters, JC
Dijkstra, PU
Postema, K
机构
[1] Univ Groningen, Ctr Med, Ctr Rehabil, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Dept Gen Practice, NL-9700 RB Groningen, Netherlands
关键词
reproducibility of results; cervical vertebrae; interobserver variation; measurement; range of motion; articular;
D O I
10.1016/j.jmpt.2005.06.009
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objective: To establish the interobserver reliability for measuring neck mobility in human subjects by means of an electromagnetic tracking device, the Flock-of-Birds system. Methods: Two observers independently and in random order assessed the cervical range-of-motion in 30 subjects with a dysfunction in the neck and shoulder region (symptomatic subjects) and 30 subjects without known pathology (asymptomatic subjects). Measurements included rotation in neutral position, in flexed position and in extended position, flexion-extension, and lateral bending (all active and passive). Reliability was analyzed by intraclass correlation coefficient (ICC) and agreement by limits of agreement and percentage of paired observations within 5 degrees, 10 degrees, and 15 degrees. Results: For asymptomatic subjects, the ICC varied from 0.57 to 0.85, and the limits of agreement varied between 14.5 degrees and 27.0 degrees.The percentage of paired observations within 5 degrees, 10 degrees, and 15 degrees ranged from 31% to 57%, 58% to 90%, and 78% to 93%, respectively. For symptomatic subjects, the ICC varied from 0.36 to 0.91, and the limits of agreement varied between 9.6 degrees and 37.8 degrees. The percentage of paired observations within 5 degrees, 10 degrees, and 15 degrees ranged from 17% to 60%, 33% to 93%, and 50% to 97%, respectively. Conclusions: Despite the use of a standardized protocol and a sophisticated measurement system, the interobserver reliability of neck mobility was variable in quality, with reliability being good in rotation in neutral position, flexion extension, and lateral bending.
引用
收藏
页码:408 / 413
页数:6
相关论文
共 15 条
[1]   3-DIMENSIONAL ANALYSIS OF NECK MOTION A CLINICAL METHOD [J].
ALUND, M ;
LARSSON, SE .
SPINE, 1990, 15 (02) :87-91
[2]  
Antonaci F, 2000, CLIN EXP RHEUMATOL, V18, pS45
[3]   Groningen Manipulation Study. The effect of manipulation of the structures of the shoulder girdle as additional treatment for symptom relief and for prevention of chronicity or recurrence of shoulder symptoms. Design of a randomized controlled trial within a comprehensive prognostic cohort study [J].
Bergman, GJD ;
Winters, JC ;
van der Heijden, GJMG ;
Postema, K ;
Meyboom-de Jong, B .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2002, 25 (09) :543-549
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Biomechanics of the cervical spine. I: Normal kinematics [J].
Bogduk, N ;
Mercer, S .
CLINICAL BIOMECHANICS, 2000, 15 (09) :633-648
[6]   Meta-analysis of normative cervical motion [J].
Chen, J ;
Solinger, AB ;
Poncet, JF ;
Lantz, CA .
SPINE, 1999, 24 (15) :1571-1578
[7]   'Coupled motions' in cervical spine rotation can be misleading. Comment on V. Feipel, B, Rondelet, J.-P. Le Pallec and M. Rooze. Normal global motion of the cervical spine: an electrogoniometric study. Clin. Biomechanics 1999; 14: 462-470 [J].
Hof, AL ;
Koerhuis, CL ;
Winters, JC .
CLINICAL BIOMECHANICS, 2001, 16 (05) :455-456
[8]   Assessment of published reliability studies for cervical spine range-of-motion measurement tools [J].
Jordan, K .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2000, 23 (03) :180-195
[9]   Neck mobility measurement by means of the 'Flock of Birds' electromagnetic tracking system [J].
Koerhuis, CL ;
Winters, JC ;
van der Helm, FCT ;
Hof, AL .
CLINICAL BIOMECHANICS, 2003, 18 (01) :14-18
[10]   Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies [J].
Meskers, CGM ;
Fraterman, H ;
van der Helm, FCT ;
Vermeulen, HM ;
Rozing, PM .
JOURNAL OF BIOMECHANICS, 1999, 32 (06) :629-633