Validation of two-fluid boiling flow model on the DEBORA benchmark experimental data

被引:0
|
作者
Gajsek, Aljosa [1 ]
Koncar, Bostjan [1 ]
Tekavcic, Matej [1 ]
Prosek, Andrej [1 ]
机构
[1] Jozef Stefan Inst, Reactor Engn Div, Jamova Cesta 39, Ljubljana 1000, Slovenia
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work simulations of 4 DEBORA experiments have been performed with ANSYS Fluent code in Eulerian two-fluid framework, using the standard wall boiling model. The cases varied by their inlet sub-cooling and consequently represented different boiling flow regimes. Temperature, void fraction, Sauter mean diameter and velocity profiles were compared with the experimental data. Preliminary analysis showed qualitatively good agreement of simulated-temperature and velocity profiles with DEBORA experiments, while more detailed study of boiling and inter-phase transfer parameters will be needed to better match the void fraction profiles and bubble diameter profiles. Mainly the simulated Sauter mean diameters also significantly over-estimated the measured values in the near-wall regions.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Numerical investigation of hydrogen flow boiling based on two-fluid model
    Kuang Y.
    Sun L.
    Wang W.
    Zhuan R.
    Zhang L.
    Huagong Xuebao/CIESC Journal, 2021, 72 : 184 - 193
  • [2] Simulation of ferrofluid flow boiling in helical tubes using two-fluid model
    Saedi, M.
    Aminfar, H.
    Mohammadpourfard, M.
    Maroofiazar, R.
    HEAT AND MASS TRANSFER, 2019, 55 (01) : 133 - 148
  • [3] DEVELOPMENT OF ADVANCED TWO-FLUID MODEL FOR BOILING TWO-PHASE FLOW IN ROD BUNDLES
    Yoshida, Hiroyuki
    Hosoi, Hideaki
    Suzuki, Takayuki
    Takase, Kazuyuki
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING 2010, VOL 4 PTS A AND B, 2011, : 1193 - +
  • [4] Numerical simulation of fluid bed drying based on two-fluid model and experimental validation
    Assari, M. R.
    Basirat Tabrizi, H.
    Saffar-Avval, M.
    APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) : 422 - 429
  • [5] An experimental investigation and two-fluid model validation for dilute viscous oil in water dispersed pipe flow
    Picchi, Davide
    Strazza, Domenico
    Demori, Marco
    Ferrari, Vittorio
    Poesio, Pietro
    Experimental Thermal and Fluid Science, 2015, 60 : 28 - 34
  • [6] An experimental investigation and two-fluid model validation for dilute viscous oil in water dispersed pipe flow
    Picchi, Davide
    Strazza, Domenico
    Demori, Marco
    Ferrari, Vittorio
    Poesio, Pietro
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 60 : 28 - 34
  • [7] Two-fluid and population balance models for subcooled boiling flow
    Yeoh, G. H.
    Tu, J. Y.
    APPLIED MATHEMATICAL MODELLING, 2006, 30 (11) : 1370 - 1391
  • [8] An experimental investigation and two-fluid model validation for dilute viscous oil in water dispersed pipe flow
    Picchi, Davide
    Strazza, Domenico
    Demori, Marco
    Ferrari, Vittorio
    Poesio, Pietro
    Experimental Thermal and Fluid Science, 2015, 60 : 28 - 34
  • [9] Numerical investigation of boiling flow of nitrogen in a vertical tube using the two-fluid model
    Li, Xiangdong
    Wang, Rongshun
    Huang, Rongguo
    Shi, Yumei
    APPLIED THERMAL ENGINEERING, 2006, 26 (17-18) : 2425 - 2432
  • [10] Prediction of subcooled flow boiling characteristics using two-fluid Eulerian CFD model
    Braz Filho, Francisco A.
    Ribeiro, Guilherme B.
    Caldeira, Alexandre D.
    NUCLEAR ENGINEERING AND DESIGN, 2016, 308 : 30 - 37