The effect of manipulation of basal pulsatile insulin on insulin action in Type 2 diabetes

被引:3
作者
Au, S
Courtney, CH
Ennis, CN
Sheridan, B
Atkinson, AB
Bell, PM
机构
[1] Royal Victoria Hosp, Reg Ctr Endocrinol & Diabet, Belfast BT12 6BA, Antrim, North Ireland
[2] Royal Victoria Hosp, Reg Endocrinol Lab, Belfast BT12 6BA, Antrim, North Ireland
关键词
hyperinsulinaemic glucose clamps; insulin action; pulsatile insulin secretion; Type; 2; diabetes;
D O I
10.1111/j.1464-5491.2005.01607.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Disordered insulin pulsatility is associated with insulin resistant states including Type 2 diabetes. However, whether abnormal basal insulin pulses play a role in the pathogenesis of insulin resistance or are simply an associated feature remains undetermined. We investigated this relationship further by studying the effect of overnight (10 h) pulsatile insulin infusion on subsequent insulin sensitivity. Methods We studied 17 Type 2 diabetic patients who underwent one of two protocols. In protocol A (10 patients) on two separate nights we infused insulin 0.1 mU/kg/min either in a constant infusion or in pulses every 13 min. Octreotide (0.43 mu g/kg/h) was given to suppress endogenous insulin secretion and physiological replacement of glucagon (30 ng/kg/h) administered. Insulin sensitivity was measured using a hyperinsulinaemic euglycaemic clamp (2 mU/kg/min) next morning. In protocol B (seven patients), we employed the same experimental procedure but used a basal insulin infusion rate of 0.09 mU/kg/min in 7-min or 13-min pulses. Results Appropriate pulse patterns were confirmed in each protocol. In protocol A, after overnight infusions, glucose infusion rates required to maintain euglycaemia at steady state hyperinsulinaemia were similar (33.9 +/- 5.2 vs. 31.2 +/- 4.1 mu mol/kg/min; P = NS). In protocol B, after overnight infusions the glucose infusion rates required during hyperinsulinaemia were significantly lower during 7-min pulses (39.9 +/- 5.7 vs. 44.7 +/- 5.6 mu mol/kg/min; P < 0.05). Conclusion There was no demonstrable priming effect derived from overnight pulsatile insulin compared with constant insulin infusion on subsequent insulin sensitivity in Type 2 diabetic subjects. The failure of 7-min pulses to exhibit an advantageous effect over 13-min pulses raises questions about the natural frequency of basal insulin pulses and their biological effect.
引用
收藏
页码:1064 / 1071
页数:8
相关论文
共 25 条
[1]   Glucosamine induces insulin resistance in vivo by affecting GLUT 4 translocation in skeletal muscle - Implications for glucose toxicity [J].
Baron, AD ;
Zhu, JS ;
Weldon, H ;
Maianu, L ;
Garvey, WT .
JOURNAL OF CLINICAL INVESTIGATION, 1995, 96 (06) :2792-2801
[2]   SUSTAINED PULSATILE INSULIN-SECRETION FROM ADENOMATOUS HUMAN BETA-CELLS - SYNCHRONOUS CYCLING OF INSULIN, C-PEPTIDE, AND PROINSULIN [J].
CHOU, HF ;
IPP, E ;
BOWSHER, RR ;
BERMAN, N ;
EZRIN, C ;
GRIFFITHS, S .
DIABETES, 1991, 40 (11) :1453-1458
[3]   Comparison of the priming effects of pulsatile and continuous insulin delivery on insulin action in man [J].
Courtney, CH ;
Atkinson, AB ;
Ennis, CN ;
Sheridan, B ;
Bell, PM .
METABOLISM-CLINICAL AND EXPERIMENTAL, 2003, 52 (08) :1050-1055
[4]  
DEBODO RC, 1963, RECENT PROG HORM RES, V19, P445
[5]   PROFOUND PERIPHERAL INSULIN RESISTANCE, INDEPENDENT OF OBESITY, IN POLYCYSTIC OVARY SYNDROME [J].
DUNAIF, A ;
SEGAL, KR ;
FUTTERWEIT, W ;
DOBRJANSKY, A .
DIABETES, 1989, 38 (09) :1165-1174
[6]   INSULIN, GLUCAGON, AND GLUCOSE EXHIBIT SYNCHRONOUS, SUSTAINED OSCILLATIONS IN FASTING MONKEYS [J].
GOODNER, CJ ;
WALIKE, BC ;
KOERKER, DJ ;
ENSINCK, JW ;
BROWN, AC ;
CHIDECKEL, EW ;
PALMER, J ;
KALNASY, L .
SCIENCE, 1977, 195 (4274) :177-179
[7]   A COMPARISON OF THE EFFECTS OF LOW-DOSE AND CONVENTIONAL-DOSE THIAZIDE DIURETIC ON INSULIN ACTION IN HYPERTENSIVE PATIENTS WITH NIDDM [J].
HARPER, R ;
ENNIS, CN ;
HEANEY, AP ;
SHERIDAN, B ;
GORMLEY, M ;
ATKINSON, AB ;
JOHNSTON, GD ;
BELL, PM .
DIABETOLOGIA, 1995, 38 (07) :853-859
[8]   Association between insulin secretory pulse frequency and peripheral insulin action in NIDDM and normal subjects [J].
Hunter, SJ ;
Atkinson, AB ;
Ennis, CN ;
Sheridan, B ;
Bell, PM .
DIABETES, 1996, 45 (05) :683-686
[9]   CYCLIC OSCILLATIONS OF BASAL PLASMA-GLUCOSE AND INSULIN CONCENTRATIONS IN HUMAN-BEINGS [J].
LANG, DA ;
MATTHEWS, DR ;
PETO, J ;
TURNER, RC .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (19) :1023-1027
[10]  
MATTHEWS DR, 1988, DIABETOLOGIA, V31, pA519