Visual and accommodative outcomes 1 year after implantation of an accommodating intraocular lens based on a new concept

被引:41
作者
Alio, Jorge L. [1 ]
Ben-nun, Joshua [2 ]
Rodriguez-Prats, Jose L. [1 ]
Plaza, Ana B. [1 ]
机构
[1] Vissum Corp, Inst Oftalmol Alicante, Dept Refract Surg, Alicante 03016, Spain
[2] NuLens Ltd, Herzliya Pituach, Israel
关键词
PRESBYOPIA; AMPLITUDE;
D O I
10.1016/j.jcrs.2009.04.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate visual outcomes and accommodative gains 1 year after implantation of the NuLens accommodating intraocular lens (IOL). SETTING: Department of Refractive Surgery, Vissum Corp., Alicante, Spain. METHODS: This study comprised patients with cataract and atrophic macular degeneration. In each patient, the accommodating IOL was implanted in the eye with the worse visual acuity. At the 12-month follow-up visit, visual acuity and accommodation were measured to determine the efficacy of the IOL. Ultrasound biomicroscopy was used to measure accommodative amplitude. RESULTS: Ten eyes of 10 patients were evaluated. The mean number of lines patients could read increased from 1.0 preoperatively to 3.8 lines 6 months postoperatively, indicating improvement in uncorrected near visual acuity after IOL implantation. The mean change in cross-section measurements of the IOL was 0.06 mm at 1 month; the value peaked at 3 months (0.21 mm), after which it decreased steadily, becoming stable at 9 months (0.09 mm, which is equivalent to 10.00 diopters [D] of accommodation). Corrected near visual acuity improved slightly (0.7 Jaeger lines) at 12 months, with the best reading distance at 10 cm. These results suggest that the near and distance visual acuities were approximately equal and, therefore, the IOL can produce accommodation of 10.00 D. CONCLUSIONS: The accommodation mechanism of the IOL can produce an ocular power variation of 10.00 D. Near visual acuity improved without compromising distance visual acuity.
引用
收藏
页码:1671 / 1678
页数:8
相关论文
共 17 条
[1]   AMPLITUDE OF ACCOMMODATION FOR DIFFERENT HEAD POSITIONS AND DIFFERENT DIRECTIONS OF EYE GAZE [J].
ATCHISON, DA ;
CLAYDON, CA ;
IRWIN, SE .
OPTOMETRY AND VISION SCIENCE, 1994, 71 (05) :339-345
[2]   Comparison of Nd:YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, or acrylic intra-ocular lenses in four European countries [J].
Auffarth, GU ;
Brezin, A ;
Caporossi, A ;
Lafuma, A ;
Mendicute, J ;
Berdeaux, G ;
Smith, AF .
OPHTHALMIC EPIDEMIOLOGY, 2004, 11 (04) :319-329
[3]   Feasibility and development of a high-power real accommodating intraocular lens [J].
Ben-nun, J ;
Alió, JL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1802-1808
[4]  
Ben-Nun Joshua, 2006, Ophthalmol Clin North Am, V19, P129
[5]   Clinical evaluation of the Crystalens AT-45 accommodating intraocular lens - Results of the US Food and Drug Administration clinical trial [J].
Cumming, JS ;
Colvard, DM ;
Dell, SJ ;
Doane, J ;
Fine, IH ;
Hoffman, RS ;
Packer, M ;
Slade, SG .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :812-825
[6]  
Dick H Burkhard, 2005, Curr Opin Ophthalmol, V16, P8, DOI 10.1097/00055735-200502000-00004
[7]  
Donders FC., 1864, ANOMALIES ACCOMMODAT
[8]  
Duane A, 1912, J AMER MED ASSOC, V59, P1010
[9]  
DUANE A, 1912, T AM MED ASS O, P383
[10]   Presbyopia and the optical changes in the human crystalline lens with age [J].
Glasser, A ;
Campbell, MCW .
VISION RESEARCH, 1998, 38 (02) :209-229