Inter-observer agreement in clinical optic disc measurement using a modified 60 D lens

被引:17
作者
Haslett, RS
Batterbury, M
Cuypers, M
Cooper, RL
机构
[1] UNIV LIVERPOOL, DEPT MED, LIVERPOOL L69 3BX, MERSEYSIDE, ENGLAND
[2] LIONS EYE INST, PERTH, WA, AUSTRALIA
关键词
inter-observer agreement; optic disc; measurement; clinical; TOPOGRAPHIC MEASUREMENTS; GLAUCOMA; REPRODUCIBILITY; SIZE;
D O I
10.1038/eye.1997.179
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the inter-observer agreement of the measurement of optic disc dimensions by two observers using a modified 60 dioptre (D) fundus examination lens, Method The vertical disc and cup diameters of 29 eyes were measured by two independent observers using a 60 D lens modified by incorporation of a 0.1 millimetre scale graticule, The vertical cup/disc ratio was calculated, Inter-observer agreement was assessed by calculation of the inter-observer differences and by the weighted kappa statistic. Results: The two observers showed good agreement for the measurement of disc diameter (mean difference -0.04; range -0.04, 0.2) and for cup diameter (mean difference -0.03; range 0.3, 0.2), Closer agreement for the vertical cup/disc ratio was achieved (mean kappa 0.96; 95% confidence limits 0.90, 1.0), The 95% confidence limit for the mean inter-observer difference in cup/disc ratio was 0.11, suggesting that a change of >0.1 in the assessment of the cup/disc ratio by this technique is significant at the 5% level, Conclusion: High inter-observer agreement of optic disc measurement can be achieved with this technique, The method has the potential to improve the clinical evaluation of the optic disc and the precision and accuracy of the clinical measurement of other fundal structures.
引用
收藏
页码:692 / 697
页数:6
相关论文
共 28 条
[1]  
ABRAMS LS, 1994, OPHTHALMOLOGY, V101, P1662
[2]   CUP/DISC RATIO - FINDINGS OF TONOMETRY AND TONOGRAPHY IN NORMAL EYE [J].
ARMALY, MF ;
SAYEGH, RE .
ARCHIVES OF OPHTHALMOLOGY, 1969, 82 (02) :191-&
[3]  
BARR DB, 1995, BRIT J OPHTHALMOL, V79, P298, DOI 10.1136/bjo.79.3.298
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
CAPRIOLI J, 1986, ARCH OPHTHALMOL-CHIC, V104, P1035
[6]  
COOPER R L, 1982, Glaucoma, V4, P169
[7]  
ELKINGTON JR, 1991, CLIN OPTICS
[8]  
Fleiss JL, 1981, STAT METHODS RATES P, V2, P22, DOI DOI 10.1002/0471445428.CH18
[9]   OPTIC DISK MORPHOMETRY IN CHRONIC PRIMARY OPEN-ANGLE GLAUCOMA .1. MORPHOMETRIC INTRAPAPILLARY CHARACTERISTICS [J].
JONAS, JB ;
GUSEK, GC ;
NAUMANN, GOH .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1988, 226 (06) :522-530
[10]  
JONAS JB, 1995, OPHTHALMOLOGY, V102, P1102