Foot Plantar Pressure Measurement System: A Review

被引:533
作者
Razak, Abdul Hadi Abdul [1 ,2 ]
Zayegh, Aladin [1 ]
Begg, Rezaul K. [3 ,4 ]
Wahab, Yufridin [5 ]
机构
[1] Victoria Univ, Sch Sci & Engn, Melbourne, Vic 3032, Australia
[2] Univ Teknol MARA, Fac Elect Engn, Shah Alam 40000, Malaysia
[3] Victoria Univ, Sch Sport & Exercise Sci SES, Melbourne, Vic 3032, Australia
[4] Victoria Univ, ISEAL, Melbourne, Vic 3032, Australia
[5] Univ Malaysia Perlis, Ctr Ind Collaborat, Sch Microelect Engn, Arau 02600, Malaysia
关键词
foot plantar pressure; pressure sensor; wireless system; SENSOR SYSTEM; WALKING; DEVICES; GAIT;
D O I
10.3390/s120709884
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Foot plantar pressure is the pressure field that acts between the foot and the support surface during everyday locomotor activities. Information derived from such pressure measures is important in gait and posture research for diagnosing lower limb problems, footwear design, sport biomechanics, injury prevention and other applications. This paper reviews foot plantar sensors characteristics as reported in the literature in addition to foot plantar pressure measurement systems applied to a variety of research problems. Strengths and limitations of current systems are discussed and a wireless foot plantar pressure system is proposed suitable for measuring high pressure distributions under the foot with high accuracy and reliability. The novel system is based on highly linear pressure sensors with no hysteresis.
引用
收藏
页码:9884 / 9912
页数:29
相关论文
共 56 条
  • [1] [Anonymous], DIAB PUBL HLTH RES D
  • [2] [Anonymous], INF RES STUD
  • [3] [Anonymous], 2004, MEMS MECH SENSORS
  • [4] Correction for sensor creep in the evaluation of long-term plantar pressure data
    Arndt, A
    [J]. JOURNAL OF BIOMECHANICS, 2003, 36 (12) : 1813 - 1817
  • [5] Gait analysis using a shoe-integrated wireless sensor system
    Bamberg, Stacy J. Morris
    Benbasat, Ari Y.
    Scarborough, Donna Moxley
    Krebs, David E.
    Paradiso, Joseph A.
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2008, 12 (04): : 413 - 423
  • [6] Benocci M., 2009, Pervasive Computing Technologies for Healthcare, VApril, P1, DOI [10.4108/ICST.PERVASIVEHEALTH2009.6032, DOI 10.4108/ICST.PERVASIVEHEALTH2009.6032]
  • [7] Best Russell, 2006, COMPUTATIONAL INTELL, V1, P1
  • [8] Wearable sensors/systems and their impact on biomedical engineering - An overview from the guest editor
    Bonato, P
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2003, 22 (03): : 18 - 20
  • [9] Measurement of In-Shoe Plantar Triaxial Stresses in High-Heeled Shoes
    Cong, Yan
    Zhang, Ming
    [J]. 2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1760 - 1763
  • [10] RECIPROCAL AIDED GAIT IN PARAPLEGIA
    CROSBIE, WJ