The Accuracy Benefit of Multiple Amperometric Glucose Sensors in People With Type 1 Diabetes

被引:20
作者
Castle, Jessica R. [1 ]
Pitts, Amy [1 ]
Hanavan, Kathryn [1 ]
Muhly, Rhonda [1 ]
El Youssef, Joseph [1 ]
Hughes-Karvetski, Colleen [2 ,3 ]
Kovatchev, Boris [2 ,3 ]
Ward, W. Kenneth [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Med, Div Endocrinol Diabet & Clin Nutr, Portland, OR 97201 USA
[2] Univ Virginia, Ctr Diabet Technol, Dept Psychiat & Neurobehav Sci, Charlottesville, VA USA
[3] Univ Virginia, Ctr Diabet Technol, Dept Syst & Informat Engn, Charlottesville, VA USA
基金
美国国家卫生研究院;
关键词
STATISTICAL VARIABLES; PRINCIPAL COMPONENTS; IMPROVEMENT; COMPLEX;
D O I
10.2337/dc11-1929
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE-To improve glucose sensor accuracy in subjects with type 1 diabetes by using multiple sensors and to assess whether the benefit of redundancy is affected by intersensor distance. RESEARCH DESIGN AND METHODS-Nineteen adults with type 1 diabetes wore four Dexcom SEVEN PLUS subcutaneous glucose sensors during two 9-h studies. One pair of sensors was worn on each side of the abdomen, with each sensor pair placed at a predetermined distance apart and 20 cm away from the opposite pair. Arterialized venous blood glucose levels were measured every 15 mm, and sensor glucose values were recorded every 5 mm. Sensors were calibrated once at the beginning of the study. RESULTS-The use of four sensors significantly reduced very large errors compared with one sensor (0.4 vs. 2.6% of errors >= 50% from reference glucose, P < 0.001) and also improved overall accuracy (mean absolute relative difference, 11.6 vs. 14.8%, P < 0.001). Using only two sensors also significantly improved very large errors and accuracy. Intersensor distance did not affect the function of sensor pairs. CONCLUSIONS-Sensor accuracy is significantly improved with the use of multiple sensors compared with the use of a single sensor. The benefit of redundancy is present even when sensors are positioned very closely together (7 mm). These findings are relevant to the design of an artificial pancreas device.
引用
收藏
页码:706 / 710
页数:5
相关论文
共 17 条
[1]   Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes [J].
Battelino, Tadej ;
Phillip, Moshe ;
Bratina, Natasa ;
Nimri, Revital ;
Oskarsson, Per ;
Bolinder, Jan .
DIABETES CARE, 2011, 34 (04) :795-800
[2]   Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Tamborlane, William V. ;
Ahmann, Andrew ;
Buse, John B. ;
Dailey, George ;
Davis, Stephen N. ;
Joyce, Carol ;
Peoples, Tim ;
Perkins, Bruce A. ;
Welsh, John B. ;
Willi, Steven M. ;
Wood, Michael A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (04) :311-320
[3]   Continuous Glucose Sensing: Future Technology Developments [J].
Brauker, Jim .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 :S25-S36
[4]  
Castle Jessica R, 2010, J Diabetes Sci Technol, V4, P221
[5]  
Clinical and Laboratory Standards Institute, 2008, PLATELET FUNCTION TE, V28, P1
[6]   Continuous Glucose Monitoring in Subjects with Type 1 Diabetes: Improvement in Accuracy by Correcting for Background Current [J].
El Youssef, Joseph ;
Castle, Jessica R. ;
Engle, Julia M. ;
Massoud, Ryan G. ;
Ward, W. Kenneth .
DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (11) :921-928
[7]   Enhanced Accuracy of Continuous Glucose Monitoring by Online Extended Kalman Filtering [J].
Facchinetti, Andrea ;
Sparacino, Giovanni ;
Cobelli, Claudio .
DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (05) :353-363
[8]   Universal Glucose Models for Predicting Subcutaneous Glucose Concentration in Humans [J].
Gani, Adiwinata ;
Gribok, Andrei V. ;
Lu, Yinghui ;
Ward, W. Kenneth ;
Vigersky, Robert A. ;
Reifman, Jaques .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (01) :157-165
[9]   Analysis of a complex of statistical variables into principal components [J].
Hotelling, H .
JOURNAL OF EDUCATIONAL PSYCHOLOGY, 1933, 24 :417-441
[10]   Analysis of a complex of statistical variables into principal components [J].
Hotelling, H .
JOURNAL OF EDUCATIONAL PSYCHOLOGY, 1933, 24 :498-520