Web Server for Peak Detection, Baseline Correction, and Alignment in Two-Dimensional Gas Chromatography Mass Spectrometry-Based Metabolomics Data

被引:15
作者
Tian, Tze-Feng [1 ,2 ]
Wang, San-Yuan [1 ,2 ]
Kuo, Tien-Chueh [2 ,5 ]
Tan, Cheng-En [1 ,2 ]
Chen, Guan-Yuan [2 ,3 ]
Kuo, Ching-Hua [2 ,3 ,4 ]
Chen, Chi-Hsin Sally [6 ]
Chan, Chang-Chuan [6 ]
Lin, Olivia A. [5 ]
Tseng, Y. Jane [1 ,2 ,3 ,5 ]
机构
[1] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, 1,Sec 4,Roosevelt Rd, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Ctr Genom Med, Metabol Core Lab, 2 Syu Jhou Rd, Taipei 10055, Taiwan
[3] Natl Taiwan Univ, Sch Pharm, Coll Med, 33 Linsen S Rd, Taipei 100, Taiwan
[4] Natl Taiwan Univ, Natl Taiwan Univ Hosp, Dept Pharm, 1 Changde St, Taipei 10048, Taiwan
[5] Natl Taiwan Univ, Grad Inst Biomed Elect & Bioinformat, 1,Sec 4,Roosevelt Rd, Taipei 10617, Taiwan
[6] Natl Taiwan Univ, Inst Occupat Med & Ind Hyg, 17 Xuzhou Rd, Taipei 100, Taiwan
关键词
CHEMOMETRIC ANALYSIS; MS DATA; METABOLITES; GC; ALGORITHM; ELECTROPHORESIS; IDENTIFICATION; SEPARATIONS; SIMILARITY; SAMPLES;
D O I
10.1021/acs.analchem.6b00755
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two-dimensional gas chromatography time-of-flight mass spectrometry (GCXGC/TOF-MS) is superior for chromatographic separation and provides great sensitivity for complex biological fluid analysis in metabolomics. However, GCXGC/TOF-MS data processing is currently limited to vendor software and typically requires several preprocessing steps. In this work, we implement a web-based platform, which we call GC(2)MS, to facilitate the application of recent advances in GCXGC/TOF-MS, especially for metabolomics studies. The core processing workflow of GC(2)MS consists of blob/peak detection, baseline correction, and blob alignment. GC(2)MS treats GCXGC/TOF-MS data as pictures and clusters the pixels as blobs according to the brightness of each pixel to generate a blob table. GC(2)MS then aligns the blobs of two GCXGC/TOF-MS data sets according to their distance and similarity. The blob distance and similarity are the Euclidean distance of the first and second retention times of two blobs and the Pearsons correlation coefficient of the two mass spectra, respectively. GC(2)MS also directly corrects the raw data baseline. The analytical performance of GC(2)MS was evaluated using GCXGC/TOF-MS data sets of Angelica sinensis compounds acquired under different experimental conditions and of human plasma samples. The results show that GC(2)MS is an easy-to-use tool for detecting peaks and correcting baselines, and GC(2)MS is able to align GCXGC/TOF-MS data sets acquired under different experimental conditions. GC(2)MS is freely accessible at http://gc2ms.web.cmdm.tw.
引用
收藏
页码:10395 / 10403
页数:9
相关论文
共 50 条
  • [41] Analyte quantification with comprehensive two-dimensional gas chromatography: Assessment of methods for baseline correction, peak delineation, and matrix effect elimination for real samples
    Samanipour, Saer
    Dimitriou-Christidis, Petros
    Gros, Jonas
    Grange, Aureline
    Arey, J. Samuel
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1375 : 123 - 139
  • [42] Simultaneous metabolomics and lipidomics analysis based on novel heart-cutting two-dimensional liquid chromatography-mass spectrometry
    Wang, Shuangyuan
    Zhou, Lina
    Wang, Zhichao
    Shi, Xianzhe
    Xu, Guowang
    ANALYTICA CHIMICA ACTA, 2017, 966 : 34 - 40
  • [43] A streak detection approach for comprehensive two-dimensional gas chromatography based on image analysis
    Li, Bo
    Reichenbach, Stephen E.
    Tao, Qingping
    Zhu, Rongbo
    NEURAL COMPUTING & APPLICATIONS, 2020, 32 (03) : 649 - 663
  • [44] Enhancing the chemical selectivity in discovery-based analysis with tandem ionization time-of-flight mass spectrometry detection for comprehensive two-dimensional gas chromatography
    Freye, Chris E.
    Moores, Nicholas R.
    Synovec, Robert E.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1537 : 99 - 108
  • [45] Petroleum Sulfur Biomarkers Analyzed by Comprehensive Two-Dimensional Gas Chromatography Sulfur-Specific Detection and Mass Spectrometry
    Lu, Hong
    Shi, Quan
    Lu, Jie
    Sheng, Guoying
    Peng, Ping'an
    Hsu, Chang Samuel
    ENERGY & FUELS, 2013, 27 (12) : 7245 - 7251
  • [46] Dynamic pressure gradient modulation for comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry detection
    Schoneich, Sonia
    Gough, Derrick, V
    Trinklein, Timothy J.
    Synovec, Robert E.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1620
  • [47] Evaluation of comprehensive two-dimensional gas chromatography coupled to rapid scanning quadrupole mass spectrometry for quantitative analysis
    Goncalves Silva, Bruno Jose
    Tranchida, Peter Quinto
    Purcaro, Giorgia
    Costa Queiroz, Maria Eugenia
    Mondello, Luigi
    Lancas, Fernando Mauro
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1255 : 177 - 183
  • [48] Pixel-by-pixel correction of retention time shifts in chromatograms from comprehensive two-dimensional gas chromatography coupled to high resolution time-of-flight mass spectrometry
    Zushi, Yasuyuki
    Gros, Jonas
    Tao, Qingping
    Reichenbach, Stephen E.
    Hashimoto, Shunji
    Arey, J. Samuel
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1508 : 121 - 129
  • [49] RGCxGC toolbox: An R-package for data processing in comprehensive two-dimensional gas chromatography-mass spectrometry
    Quiroz-Moreno, Cristian
    Furlan, Mayra Fontes
    Belinato, Joao Raul
    Augusto, Fabio
    Alexandrino, Guilherme L.
    Mogollon, Noroska Gabriela Salazar
    MICROCHEMICAL JOURNAL, 2020, 156
  • [50] COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY-MASS SPECTROMETRY: RECENT EVOLUTION AND CURRENT TRENDS
    Tranchida, Peter Q.
    Franchina, Flavio A.
    Dugo, Paola
    Mondello, Luigi
    MASS SPECTROMETRY REVIEWS, 2016, 35 (04) : 524 - 534