Combination of cationic surfactant-assisted solid-phase extraction with field-amplified sample stacking for highly sensitive analysis of chlorinated acid herbicides by capillary zone electrophoresis

被引:17
作者
Xu, Y
Qin, WD
Lau, YH
Li, SFY
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[2] Beijing Normal Univ, Dept Chem, Beijing 100875, Peoples R China
关键词
capillary electrophoresis; cationic surfactant-assisted solid-phase extraction; chlorinated acid herbicide; field-amplified sample stacking; poly(vinyl alcohol)-coated capillary;
D O I
10.1002/elps.200400213
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This report describes a novel online field-amplified sample stacking (FASS) procedure to analyze 16 chlorinated acid herbicides. By using a poly(vinyl alcohol) (PVA)-coated capillary to reduce electroosmotic flow and introducing a methanol-water plug before sample loading, the sample injection time could be very long without loss of sample and separation efficiency. Under the optimized condition, the FASS procedure could provide great sensitivity enhancement (5000-10 000-fold) and satisfactory reproducibility (relative standard deviations of migration times less than 2.4%, relative standard deviations of peak areas less than 8.0%). Combined with cationic surfactant-assisted solid-phase extraction (CSA-SPE), the limit of detection of the herbicides ranged from 0.269 to 20.3 ppt, which are two orders lower than those of the US Environmental Protection Agency standard method 515.1. The CSA-SPE-FASS-CE method was successfully applied to the analysis of local pond water.
引用
收藏
页码:3507 / 3517
页数:11
相关论文
共 62 条
[1]  
Abu-Shammala F, 1999, ANAL LETT, V32, P3083
[2]   Large-volume stacking for quantitative analysis of anions in capillary electrophoresis .1. Large-volume stacking with polarity switching [J].
Albert, M ;
Debusschere, L ;
Demesmay, C ;
Rocca, JL .
JOURNAL OF CHROMATOGRAPHY A, 1997, 757 (1-2) :281-289
[3]  
Belder D, 1999, J MICROCOLUMN SEP, V11, P209, DOI 10.1002/(SICI)1520-667X(1999)11:3<209::AID-MCS6>3.0.CO
[4]  
2-G
[5]   Influence of pH*-value of methanolic electrolytes on electroosmotic flow in hydrophilic coated capillaries [J].
Belder, D ;
Elke, K ;
Husmann, H .
JOURNAL OF CHROMATOGRAPHY A, 2000, 868 (01) :63-71
[6]   LARGE-VOLUME STACKING OF ANIONS IN CAPILLARY ELECTROPHORESIS USING AN ELECTROOSMOTIC FLOW MODIFIER AS A PUMP [J].
BURGI, DS .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3726-3729
[7]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[8]   Sample stacking revisited: A personal perspective [J].
Chien, RL .
ELECTROPHORESIS, 2003, 24 (03) :486-497
[9]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[10]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050