Normothermic Machine Perfusion in Renal Transplantation

被引:3
作者
Norton, William G. [1 ]
Pearson, Robert [1 ]
Devlin, Joanne [1 ]
Nicholson, Michael L. [2 ]
Hosgood, Sarah A. [2 ]
机构
[1] Queen Elizabeth Univ Hosp, Dept Renal Transplantat, Glasgow, Lanark, Scotland
[2] Univ Cambridge, Addenbrookes Hosp, Dept Surg, Cambridge, England
关键词
Normothermic machine perfusion; Kidney; Transplantation; DECLINED HUMAN KIDNEYS; CIRCULATORY DEATH; PORCINE KIDNEYS; GRAFT FUNCTION; PRESERVATION; DONATION; STORAGE; INJURY; 1ST; DONORS;
D O I
10.1007/s40472-022-00378-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose of Review Normothermic machine perfusion (NMP) is a promising new tool in kidney transplantation to improve the outcome of marginal donor kidney transplantation. This review examines the current evidence for NMP in clinical practice and considers how the technology may be used in the future. Recent Findings and Summary There is emerging evidence to suggest that NMP has the potential to expand the donor pool of transplantable organs. The safety and feasibility of NMP have been established in a number of clinical studies but more research is needed to optimise the perfusion conditions. NMP shows promise as a viability assessment tool with particular focus on biomarkers and imaging techniques which provide real-time information to facilitate transplantation decision-making. Moreover, the exciting development of new potential therapeutics such as cell and gene-based therapies which are deliverable during NMP may also improve and recondition grafts prior to implantation.
引用
收藏
页码:308 / 317
页数:10
相关论文
共 50 条
[41]   The association between hemoglobin levels and renal function parameters during normothermic machine perfusion: A retrospective cohort study using porcine kidneys [J].
van Furth, L. Annick ;
Huijink, Tobias M. ;
van Leeuwen, L. Leonie ;
Maassen, Hanno ;
Lantinga, Veerle A. ;
Ogurlu, Baran ;
Hamelink, Tim L. ;
Pool, Merel B. F. ;
Schutter, Rianne ;
Veldhuis, Susanne Z. J. ;
Ottens, Petra J. ;
Moers, Cyril ;
Berger, Stefan. P. ;
Leuvenink, Henri G. D. ;
Posma, Rene A. ;
Venema, Leonie H. .
ARTIFICIAL ORGANS, 2024, 48 (08) :862-875
[42]   A Meta-Analysis and Systematic Review of Normothermic and Hypothermic Machine Perfusion in Liver Transplantation [J].
Mugaanyi, Joseph ;
Dai, Lei ;
Lu, Changjiang ;
Mao, Shuqi ;
Huang, Jing ;
Lu, Caide .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (01)
[43]   Preoperative Function Assessment of Ex Vivo Kidneys with Supervised Machine Learning Based on Blood and Urine Markers Measured during Normothermic Machine Perfusion [J].
Markgraf, Wenke ;
Malberg, Hagen .
BIOMEDICINES, 2022, 10 (12)
[44]   Normothermic machine perfusion of kidneys: current strategies and future perspectives [J].
Messner, Franka ;
Bogensperger, Christina ;
Hunter, James P. ;
Kaths, Moritz J. ;
Moers, Cyril ;
Weissenbacher, Annemarie .
CURRENT OPINION IN ORGAN TRANSPLANTATION, 2022, 27 (05) :446-453
[45]   Pilot, Open, Randomized, Prospective Trial for Normothermic Machine Perfusion Evaluation in Liver Transplantation From Older Donors [J].
Ghinolfi, Davide ;
Rreka, Erion ;
De Tata, Vincenzo ;
Franzini, Maria ;
Pezzati, Daniele ;
Fierabracci, Vanna ;
Masini, Matilde ;
Cacciatoinsilla, Andrea ;
Bindi, Maria Lucia ;
Marselli, Lorella ;
Mazzotti, Valentina ;
Morganti, Riccardo ;
Marchetti, Piero ;
Biancofiore, Giandomenico ;
Campani, Daniela ;
Paolicchi, Aldo ;
De Simone, Paolo .
LIVER TRANSPLANTATION, 2019, 25 (03) :436-449
[46]   Evolving Trends in Machine Perfusion for Liver Transplantation [J].
Dutkowski, Phillipp ;
Guarrera, James V. ;
De Jonge, Jeroen ;
Martins, Paulo N. ;
Porte, Robert J. ;
Clavien, Pierre-Alain .
GASTROENTEROLOGY, 2019, 156 (06) :1542-1547
[47]   Brief Normothermic Machine Perfusion Rejuvenates Discarded Human Kidneys [J].
Hameed, Ahmer M. ;
Lu, David B. ;
Patrick, Ellis ;
Xu, Bo ;
Hu, Min ;
Chew, Yi Vee ;
Keung, Karen ;
P'ng, Chow H. ;
Gaspi, Renan ;
Zhang, Chris ;
Robertson, Paul ;
Alexander, Stephen ;
Thomas, Gordon ;
Laurence, Jerome ;
De Roo, Ronald ;
Wong, Germaine ;
Miraziz, Ray ;
O'Grady, Greg ;
Yuen, Lawrence ;
Hawthorne, Wayne J. ;
Rogers, Natasha M. ;
Pleass, Henry C. .
TRANSPLANTATION DIRECT, 2019, 5 (11) :E502
[48]   A Comparison of Pulsatile Hypothermic and Normothermic Ex Vivo Machine Perfusion in a Porcine Kidney Model [J].
Vallant, Natalie ;
Wolfhagen, Nienke ;
Sandhu, Bynvant ;
Hamaoui, Karim ;
Cook, Terence ;
Pusey, Charles ;
Papalois, Vassilios .
TRANSPLANTATION, 2021, 105 (08) :1760-1770
[49]   Preservation of coagulation function by normothermic machine perfusion in liver transplant as evidenced by thromboelastography parameters [J].
Su, Leon L. ;
Secor, Daniel T. ;
Mcgary, Alyssa K. ;
Nguyen, Michelle C. ;
Jadlowiec, Caroline C. ;
Williams III, Lance A. ;
Kinard, Theresa N. ;
Adamski, Jill ;
Stoker, Alex D. ;
Frasco, Peter E. .
LIVER TRANSPLANTATION, 2025, 31 (04) :464-475
[50]   'Back-to-base' combined hypothermic and normothermic machine perfusion of human donor livers [J].
van Leeuwen, Otto B. ;
Lantinga, Veerle A. ;
Lascaris, Bianca ;
Thorne, Adam M. ;
Bodewes, Silke B. ;
Nijsten, Maarten W. ;
de Meijer, Vincent E. ;
Porte, Robert J. .
NATURE PROTOCOLS, 2025,