Flexible piezoresistive sensor matrix based on a carbon nanotube PDMS composite for dynamic pressure distribution measurement

被引:47
作者
Ramalingame, Rajarajan [1 ]
Hu, Zheng [1 ]
Gerlach, Carina [1 ]
Rajendran, Dhivakar [1 ]
Zubkova, Tatiana [2 ]
Baumann, Reinhard [2 ]
Kanoun, Olfa [1 ]
机构
[1] Tech Univ Chemnitz, Chair Measurement & Sensor Technol, D-09126 Chemnitz, Germany
[2] Tech Univ Chemnitz, Dept Digital Printing & Imaging Technol, D-09126 Chemnitz, Germany
关键词
D O I
10.5194/jsss-8-1-2019
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A highly flexible, piezoresistive sensor matrix based on a carbon nanotube (CNT) polymer composite is developed for pressure distribution measurement applications. With an overall height of about 400 mu m, the sensors can measure pressure directly, without any deformation elements, such as a cantilever or a deformation membrane. The measurement range is from 2.5 to 640 kPa. Both the position and the pressure of the applied load can be measured and visualized as a resistance change. The relative resistance measurement deviation of the data acquisition system is lower than 3 % for the resistance range of 610 Omega to 380 k Omega. This corresponds to a systematic deviation of pressure measurement of less than 3 % in the measurement range. Besides the measurement of pressure, different sizes of loads can be detected as well. The developed fast and compact measurement system allows dynamic pressure measurement, such as gait analysis when used in an insole application.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 16 条
[1]   Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review [J].
Amjadi, Morteza ;
Kyung, Ki-Uk ;
Park, Inkyu ;
Sitti, Metin .
ADVANCED FUNCTIONAL MATERIALS, 2016, 26 (11) :1678-1698
[2]   Localization of Humans, Objects, and Robots Interacting on Load-Sensing Floors [J].
Andries, Mihai ;
Simonin, Olivier ;
Charpillet, Francois .
IEEE SENSORS JOURNAL, 2016, 16 (04) :1026-1037
[3]  
[Anonymous], 2012, INT MULTICONFERENCE
[4]  
[Anonymous], EUR 2017 C PAR FRANC
[5]   Measurement errors in the scanning of piezoresistive sensors arrays [J].
D'Alessio, T .
SENSORS AND ACTUATORS A-PHYSICAL, 1999, 72 (01) :71-76
[6]   A flexible two dimensional force sensor using PDMS nanocomposite [J].
da Costa, Tallis H. ;
Choi, Jin-Woo .
MICROELECTRONIC ENGINEERING, 2017, 174 :64-69
[7]   Printed MWCNT-PDMS-Composite Pressure Sensor System for Plantar Pressure Monitoring in Ulcer Prevention [J].
Gerlach, Carina ;
Krumm, Dominik ;
Illing, Marko ;
Lange, Justin ;
Kanoun, Olfa ;
Odenwald, Stephan ;
Huebler, Arved .
IEEE SENSORS JOURNAL, 2015, 15 (07) :3647-3656
[8]   Between-day reliability of repeated plantar pressure distribution measurements in a normal population [J].
Gurney, Jason K. ;
Kersting, Uwe G. ;
Rosenbaum, Dieter .
GAIT & POSTURE, 2008, 27 (04) :706-709
[9]  
Hu Z, 2018, INT MULTICONF SYST, P632, DOI 10.1109/SSD.2018.8570666
[10]   Tactile sensing in dexterous robot hands - Review [J].
Kappassov, Zhanat ;
Corrales, Juan-Antonio ;
Perdereau, Veronique .
ROBOTICS AND AUTONOMOUS SYSTEMS, 2015, 74 :195-220