Determination of choline and derivatives with a solid-contact ion-selective electrode based on octaamide cavitand and carbon nanotubes

被引:42
作者
Ampurdanes, Jordi [1 ]
Crespo, Gaston A. [1 ]
Maroto, Alicia [1 ]
Angeles Sarmentero, M. [2 ]
Ballester, Pablo [2 ,3 ]
Xavier Rius, F. [1 ]
机构
[1] Univ Rovira & Virgili, Dept Analyt & Organ Chem, Tarragona 43007, Spain
[2] Inst Chem Res Catalonia ICIQ, Tarragona 43007, Spain
[3] Catalan Inst Res & Adv Studies ICREA, Barcelona 08010, Spain
关键词
Solid-contact sensor; Single-walled carbon nanotubes; Choline; Octaamide cavitand; Ion-selective electrode; ELECTROCHEMICAL DETECTION; WHOLE-BLOOD; ACETYLCHOLINE; SENSORS; PLASMA; CHROMATOGRAPHY; MEMBRANE; RECEPTOR; BETAINE;
D O I
10.1016/j.bios.2009.07.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new solid-contact ion-selective electrode has been developed for determining choline and derivatives in aqueous solutions. The backbone of this new potentiometric sensor is the conjunction of the cavitand receptor, as the molecular recognition element, and a network of non-carboxylated single-walled carbon nanotubes, acting as a solid transducer material. The octaamide cavitand, a synthetic receptor that is highly selective for biologically important trimethyl alkylammonium cations such as choline, acetylcholine or carnitine, makes the selective determination of these compounds possible for the first time. The guest-host interaction takes place in the acrylate ion-selective membrane of the solid-contact electrode. The sensor was characterized by electrochemical impedance spectroscopy and environmental scanning electron microscopy. The new electrode displays a nearly Nernstian slope (57.3 +/- 1.0 mV/decade) and very stable behaviour (Delta E/Delta t = 224 mu V h(-1)) throughout the dynamic range (10(-5) to 10(-1) M). The limit of detection of 10(-6.4) M and the high selectivities obtained will enable choline and derivatives to be determined in biological samples. Finally, the stability of the electrical potential of the new solid-contact electrode was examined by performing current-reversal chronopotentiometry and the influence of the interfacial water film was evaluated by the potentiometric water layer test. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 31 条
  • [1] Homogeneous chemiluminescent assays for free choline in human plasma and whole blood
    Adamczyk, Maciej
    Brashear, R. Jeffrey
    Mattingly, Phillip G.
    Tsatsos, Panagiota H.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 579 (01) : 61 - 67
  • [2] Selectivity of potentiometric ion sensors
    Bakker, E
    Pretsch, E
    Bühlmann, P
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (06) : 1127 - 1133
  • [3] Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    Bakker, E
    Buhlmann, P
    Pretsch, E
    [J]. CHEMICAL REVIEWS, 1997, 97 (08) : 3083 - 3132
  • [4] Modern Potentiometry
    Bakker, Eric
    Pretsch, Ernoe
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (30) : 5660 - 5668
  • [5] A synthetic receptor for choline and carnitine
    Ballester, P
    Shivanyuk, A
    Far, AR
    Rebek, J
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (47) : 14014 - 14016
  • [6] Hybrid cavitand-resorcin[4] arene receptor for the selective binding of choline and related compounds in protic media
    Ballester, Pablo
    Sarmentero, M. Angeles
    [J]. ORGANIC LETTERS, 2006, 8 (16) : 3477 - 3480
  • [7] Electrochemical detection of acetylcholine and choline: application to the quantitative nonradiochemical evaluation of choline transport
    Barkhimer, Tatyana V.
    Kirchhoff, Jon R.
    Hudson, Richard A.
    Messer, William S., Jr.
    Tillekeratne, L. M. Viranga
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 392 (04) : 651 - 662
  • [8] Potentiometric ion sensors
    Bobacka, Johan
    Ivaska, Ari
    Lewenstam, Andrzej
    [J]. CHEMICAL REVIEWS, 2008, 108 (02) : 329 - 351
  • [9] Solid contact potentiometric sensors for trace level measurements
    Chumbimuni-Torres, KY
    Rubinova, N
    Radu, A
    Kubota, LT
    Bakker, E
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (04) : 1318 - 1322
  • [10] Synthesis of phosphatidylcholine, a typical eukaryotic phospholipid, is necessary for full virulence of the intracellular bacterial parasite Brucella abortus
    Conde-Alvarez, Raquel
    Grillo, Maria J.
    Salcedo, Suzana P.
    de Miguel, Maria J.
    Fugier, Emilie
    Gorvel, Jean Pierre
    Moriyon, Ignacio
    Iriarte, Maite
    [J]. CELLULAR MICROBIOLOGY, 2006, 8 (08) : 1322 - 1335