Optimal selections of orthodontic mini-implant diameter and length by biomechanical consideration: A three-dimensional finite element analysis

被引:16
作者
Jiang, Lin [1 ]
Kong, Liang [1 ,2 ]
Li, Tao [1 ]
Gu, Zexu [1 ]
Hou, Rui [2 ]
Duan, Yinzhong [1 ]
机构
[1] Fourth Mil Med Univ, Dept Orthodont, Sch Stomatol, Xian 710032, Peoples R China
[2] Fourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R China
关键词
Mini-implant; Anchorage; Finite element analysis; Diameter; Length; ENDOSSEOUS IMPLANTS; PRIMARY STABILITY; POSTERIOR REGION; ANCHORAGE; BONE; ADOLESCENTS; TORQUE;
D O I
10.1016/j.advengsoft.2009.05.008
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A finite element analysis was carried out to evaluate continuous and simultaneous variations of orthodontic mini-implant diameter and length, and to identify their optimal ranges in the maxillary posterior region. Within the ranges of diameter from 1.0 mm to 2.0 mm and the length from 6.0 mm to 16.0 mm, our results showed that the increases of the diameter and length reduced the maximum equivalent stresses in cortical, cancellous bones and mini-implant by 80.94%, 91.84% and 86.11%, respectively, and the maximum displacement in the mini-implant by 81.29%. When the diameter exceeded 1.5 mm and the length exceeded 11.0 mm, the mini-implant achieved the best stability and the lowest levels of stress and displacement. At the similar increment, the change in the diameter was more effective than the change of length in reducing bone-implant complex stresses and enhancing mini-implant stability. Diameter exceeding 1.5 mm in combination with the longest length in safety range were the optimal biomechanical choice for the maxillary posterior region in a screwed orthodontic mini-implant. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1124 / 1130
页数:7
相关论文
共 50 条
[21]   A simple three-dimensional stent for proper placement of mini-implant [J].
Sumathi Felicita A. .
Progress in Orthodontics, 14 (1)
[22]   Three-dimensional finite element analysis of the stability of mini-implants close to the roots of adjacent teeth upon application of bite force [J].
Zhou, Guanjun ;
Zhang, Xiaoli ;
Qie, Hui ;
Li, Chenxi ;
Lu, Lin ;
Shan, Lihua .
DENTAL MATERIALS JOURNAL, 2018, 37 (05) :851-857
[23]   Biomechanical Three-Dimensional Finite Element Analysis of Single Implant-Supported Prostheses in the Anterior Maxilla, with Different Surgical Techniques and Implant Types [J].
Verri, Fellippo Ramos ;
Santiago, Joel Ferreira, Jr. ;
Faria Almeida, Daniel Augusto ;
de Souza Batista, Victor Eduardo ;
Araujo Lemos, Cleidiel Aparecido ;
Mello, Caroline Cantieri ;
Pellizzer, Eduardo Piza .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) :E191-E198
[24]   Biomechanical effects of inclined implant shoulder design in all-on-four treatment concept: a three-dimensional finite element analysis [J].
Aktas, Taha ;
Diker, Nurettin .
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2023, 68 (06) :583-591
[25]   Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: A three-dimensional finite element analysis [J].
Liu, Jingyin ;
Pan, Shaoxia ;
Dong, Jing ;
Mo, Zhongjun ;
Fan, Yubo ;
Feng, Hailan .
JOURNAL OF DENTISTRY, 2013, 41 (03) :241-249
[26]   Influence of Socket-shield technique on the biomechanical response of dental implant: three-dimensional finite element analysis [J].
Mendes Tribst, Joao Paulo ;
de Oliveira Dal Piva, Amanda Maria ;
Souto Borges, Alexandre Luiz ;
Bottino, Marco Antonio .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (06) :224-231
[27]   Extrasinus Zygomatic Implant Placement in the Rehabilitation of the Atrophic Maxilla: Three-Dimensional Finite Element Stress Analysis [J].
Romeed, Shihab A. ;
Hays, Robert Nigel ;
Malik, Raheel ;
Dunne, Stephen M. .
JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (02) :E1-E6
[28]   Influence of Implant Length and Diameter, Bicortical Anchorage, and Sinus Augmentation on Bone Stress Distribution: Three-Dimensional Finite Element Analysis [J].
Moriwaki, Hiroyoshi ;
Yamaguchi, Satoshi ;
Nakano, Tamaki ;
Yamanishi, Yasufumi ;
Imazato, Satoshi ;
Yatani, Hirofumi .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (04) :E84-E91
[29]   Orthodontic mini-implant stability in different healing times before loading: A microscopic computerized tomographic and biomechanical analysis [J].
Zhao, Lixing ;
Xu, Zhenrui ;
Yang, Zhi ;
Wei, Xing ;
Tang, Tian ;
Zhao, Zhihe .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (02) :196-202
[30]   Three-dimensional analysis of tooth movement after intrusion of a supraerupted molar using a mini-implant with partial-fixed orthodontic appliances [J].
Lee, Shin-Jae ;
Jang, Sook-Yun ;
Chun, Youn-Sic ;
Lim, Won Hoe .
ANGLE ORTHODONTIST, 2013, 83 (02) :274-279