Preliminary result of bunch length measurement using a modified Michelson interferometer

被引:2
|
作者
Lin Xu-Ling [1 ,2 ]
Zhang Jian-Bing [1 ]
Luo Feng [1 ,2 ]
Bei Hua [1 ,2 ]
Lu Shan-Liang [1 ]
Yu Tie-Min [1 ]
Dai Zhi-Min [1 ,2 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
关键词
femtosecond linear accelerator; bunch length; interferometer; hollow retroreflector; CHARGED-PARTICLE BUNCH; SHAPE;
D O I
10.1088/1674-1137/33/10/015
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Based on the femtosecond accelerator device which was built at the Shanghai Institute of Applied Physics (SINAP), recently a modified far infrared Michelson interferometer has been developed to measure the length of electron bunches via the optical autocorrelation method. Compared with our former normal Michelson interferometer, we use a hollow retroreflector instead of a flat mirror as the reflective mirror. The experimental setup and results of the bunch length measurement will be described in this paper.
引用
收藏
页码:901 / 904
页数:4
相关论文
共 50 条
  • [1] Preliminary result of bunch length measurement using a modified Michelson interferometer
    林栩凌
    张建兵
    雒峰
    卑华
    陆善良
    俞铁民
    戴志敏
    中国物理C, 2009, (10) : 901 - 904
  • [3] Improvement on a Michelson interferometer for bunch length measurement of a femtosecond accelerator
    Lin Xuling
    Zhang Jianbing
    Bei Hua
    Dai Zhimin
    NUCLEAR SCIENCE AND TECHNIQUES, 2009, 20 (01) : 1 - 4
  • [4] Nanonewton force measurement using a modified Michelson interferometer
    Tahviliyan, Masoud
    Charsooghi, Mohammad A.
    Akhlaghi, Ehsan A.
    Tavassoly, Mohammad Taghi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (05)
  • [5] Optoelectronic phase delay measurement for a modified Michelson interferometer
    Bruns, Thomas
    Blume, Frank
    Baaske, Kai
    Bieler, Mark
    Volkers, Henrik
    MEASUREMENT, 2013, 46 (05) : 1762 - 1765
  • [6] Phase transition thermal expansion measurement technique using a modified Michelson interferometer
    Korman, V
    Gregory, DA
    Banish, RM
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2004, 6 (08): : 781 - 786
  • [7] Non-contact measurement of intraocular pressure using a modified Michelson interferometer
    Drescher, J
    Stork, W
    Hey, S
    Gundlach, A
    Glaser, KDM
    Kreiner, C
    OPHTHALMIC TECHNOLOGIES IX, PROCEEDINGS OF, 1999, 3591 : 104 - 113
  • [8] Absolute distance measurement by using modified dual-wavelength heterodyne Michelson interferometer
    Chen, Kun-Huang
    Chen, Jing-Heng
    Lu, Shen-Hua
    Chang, Wei-Yao
    Wu, Chi-Chang
    OPTICS COMMUNICATIONS, 2009, 282 (09) : 1837 - 1840
  • [9] Transverse coherence measurement using a folded Michelson interferometer
    Dean, Jesse
    Bercx, Martin
    Nantel, Marc
    Marjoribanks, Robin
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (06) : 1742 - 1746
  • [10] MEASUREMENT OF MICROCURRENT BY THE MICHELSON INTERFEROMETER
    CHEN, IH
    APPLIED OPTICS, 1962, 1 (04): : 536 - 537