Retrospective Transmit Beamforming and Coherent Plane-Wave Compounding for Microvascular Doppler Imaging: A Comparison Study

被引:8
|
作者
Golfetto, Cristiana [1 ,2 ]
Ekroll, Ingvild Kinn [1 ,2 ,3 ]
Torp, Hans [1 ,2 ]
Lovstakken, Lasse [1 ,2 ]
Avdal, Jorgen [1 ,2 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Ctr Innovat Ultrasound Solut CIUS, N-7491 Trondheim, Norway
[2] Norwegian Univ Sci & Technol NTNU, Dept Circulat & Med Imaging, N-7030 Trondheim, Norway
[3] St Olavs Hosp HF, Kirurg Klin, N-7030 Trondheim, Norway
关键词
Imaging; Signal to noise ratio; Apertures; Array signal processing; Clutter; Image resolution; Doppler effect; Coherent plane-wave compounding (CPWC); microvascular Doppler imaging; retrospective transmit beamforming (RTB); synthetic transmit focusing; FRAME RATE ULTRASONOGRAPHY; ULTRASOUND; RESOLUTION; FILTER;
D O I
10.1109/TUFFC.2020.3033719
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Imaging blood flow in small vessels is of great clinical value for evaluating increased vascularization, potentially related to angiogenesis in cancer or inflammation processes in musculoskeletal disease. Using a traditional duplex imaging approach, a major challenge in color Doppler imaging is the limited amount of samples available for clutter filtering. Coherent plane-wave compounding (CPWC) enables a continuous high frame rate acquisition and improved image quality due to dynamic transmit focusing. However, the presence of moving scatterers in the image can lead to a loss in signal-to-noise ratio (SNR) and contrast. In this study, typical CPWC sequences for low-flow imaging were compared with retrospective transmit beamforming (RTB) sequences with similar frame rates and transmit power. The comparison was based on resolution, contrast, and SNR, using a stationary phantom, a flow phantom, a thread phantom, and in vivo recordings of blood vessels in the thyroid and kidney. A model was developed to estimate the difference in SNR between RTB and CPWC in the presence of static and moving scatterers while varying the transmit sequence parameters. The model predicted that RTB may yield an increased SNR compared with CPWC, especially for flow imaging, where the SNR difference reached 6 dB for a maximum velocity of 15 cm/s. The measured SNR values were in agreement with the predicted values, both in the case of stationary scatterers and for the flow phantom. We further demonstrated that reducing beam density to increase frame rate is associated with spatial undersampling (stripe) artifacts for RTB and grating lobes for CPWC. Both phantom and in vivo results indicate that transmit focusing may be beneficial in a low-flow imaging setup that, combined with adaptive clutter filtering, can yield superior microvascular imaging.
引用
收藏
页码:1105 / 1116
页数:12
相关论文
共 50 条
  • [1] Coherent Plane-Wave Compounding and Minimum Variance Beamforming
    Austeng, Andreas
    Nilsen, Carl-Inge Colombo
    Jensen, Are Charles
    Nasholm, Sven Peter
    Holm, Sverre
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2448 - 2451
  • [2] FOURIER DOMAIN BEAMFORMING FOR COHERENT PLANE-WAVE COMPOUNDING
    Cohen, Regev
    Sde-Chen, Yael
    Chernyakova, Tanya
    Fraschini, Christophe
    Bercoff, Jeremy
    Eldar, Yonina C.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [3] Ultrasound Plane-Wave Imaging with Delay Multiply And Sum Beamforming and Coherent Compounding
    Matrone, Giulia
    Savoia, Alessandro S.
    Caliano, Giosue
    Magenes, Giovanni
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 3223 - 3226
  • [4] Mean-Squared Error Beamforming for Coherent Plane-Wave Compounding
    Nguyen, Nghia Q.
    Prager, Richard W.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 316 - 319
  • [5] RESOLUTION OF THE ULTRASOUND DOPPLER SYSTEM USING COHERENT PLANE-WAVE COMPOUNDING TECHNIQUE
    Sheina, Iryna, V
    Barannik, Eugen A.
    EAST EUROPEAN JOURNAL OF PHYSICS, 2022, (01): : 116 - 122
  • [6] Axial lobes in Coherent Plane-Wave Compounding
    Rodriguez-Molares, Alfonso
    Avdal, Jorgen
    Torp, Hans
    Lovstakken, Lasse
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [7] The Angular Apodization in Coherent Plane-Wave Compounding
    Rodriguez-Molares, Alfonso
    Torp, Hans
    Denarie, Bastien
    Lovstakken, Lasse
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (11) : 2018 - 2023
  • [8] Improved Plane-Wave Ultrasound Beamforming by Incorporating Angular Weighting and Coherent Compounding in Fourier Domain
    Chen, Chuan
    Hendriks, Gijs A. G. M.
    van Sloun, Ruud J. G.
    Hansen, Hendrik H. G.
    de Korte, Chris L.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (05) : 749 - 765
  • [9] Neighborhood Singular Value Decomposition Filter and Application in Adaptive Beamforming for Coherent Plane-Wave Compounding
    Feng, Shuai
    Wang, Yadan
    Zheng, Chichao
    Han, Zhihui
    Peng, Hu
    APPLIED SCIENCES-BASEL, 2020, 10 (16):
  • [10] Minimum Variance Beamformers for Coherent Plane-Wave Compounding
    Nguyen, Nghia Q.
    Prager, Richard W.
    MEDICAL IMAGING 2017: ULTRASONIC IMAGING AND TOMOGRAPHY, 2017, 10139