An On-Line Measurement Method of Zero-Sequence Parameters of Double-Line on the Same Tower Based on WAMS

被引:0
|
作者
Xue Zhiying [1 ]
Liang Zhirui [1 ]
机构
[1] N China Elect Power Univ, Sch Elect & Elect Engn, Baoding, Peoples R China
关键词
wide area measurement system(WAMS); double-line on the same tower; zero-sequence parameter; on-line measurement; mutual impedance; coupling capacitance;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the widely use of double-fine and multiple-line on the same tower in power transmission network, their zero-sequence parameters on-line measurement becomes one of the hotspots of research. Based on the distributed parameter model of double-line, on-line measurement method using WAMS data is proposed in this paper. The physical model takes all electromagnetic coupling effects into consideration, which contains zero-sequence impedance and capacitance, coupling capacitance between lines. The mathematical model, telegraph equation, is set up. With the help of WAMS, all the parameters considered are solved. Numerical simulation result shows that this method is of great convenience and high accuracy that can meet the needs of parameters on-line measurement in electrical engineering.
引用
收藏
页码:1664 / 1667
页数:4
相关论文
共 50 条
  • [1] Parameters estimation for zero-sequence parameter on-line measurement of transmission lines with mutual inductance
    Xue, Zhi-Ying
    Liang, Zhi-Rui
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (04): : 954 - 959
  • [2] Practical calculation method and system of transmission line zero-sequence parameters
    Wang K.
    Jiang Y.
    Liu J.
    Chao P.
    Sun Z.
    Bao B.
    Li W.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2021, 41 (04): : 219 - 224
  • [3] On-line estimation of the stator resistance of induction machines based on zero-sequence model
    Jacobina, CB
    Chaves, JE
    Lima, AMN
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (02) : 346 - 353
  • [4] Online measuring of zero-sequence parameters for coupled double-circuit transmission line
    Liang, Z. (Zhiruil@sohu.com), 1600, Electric Power Automation Equipment Press (33):
  • [5] A new method for fault line selection based on correlation between zero-sequence voltage in bus and zero-sequence current in feeders
    Xiang, Yunkun
    Jiang, Yun
    Ning, Yuanzhi
    Tao, Fang
    Liu, Bohan
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1196 - 1199
  • [6] A capacitive current compensation algorithm on zero-sequence parameters live line measurement of transmission lines
    Mao, Peng
    Zhang, Chengxue
    Wang, Yuanyuan
    Bai, Richang
    Hu, Zhijian
    Shuai, Lingling
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (17): : 55 - 58
  • [7] A new method for live line measurement of zero-sequence parameters of transmission line containing t-connection transmission line with mutual inductance and its engineering application
    Fang, Li-Hua
    Hu, Zhi-Jian
    Dianwang Jishu/Power System Technology, 2010, 34 (04): : 204 - 208
  • [8] MEASUREMENT OF ZERO-SEQUENCE CURRENTS IN A 3-PHASE LINE WITH GROUNDED NEUTRAL
    MIKHAILO.MI
    KALYUZHN.VF
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1973, 27 (07) : 27 - 30
  • [9] On-Line Transmission Line Zero Sequence Impedance Estimation Using Phasor Measurement Units
    Karegar, H. Kazemi.
    Alinejad, B.
    2012 22ND AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC): GREEN SMART GRID SYSTEMS, 2012,