Influence of Preparation Design, Marginal Gingiva Location, and Tooth Morphology on the Accuracy of Digital Impressions for Full-Crown Restorations: An In Vitro Investigation

被引:21
作者
Bernauer, Selina A. [1 ]
Mueller, Johannes
Zitzmann, Nicola U. [1 ]
Joda, Tim [1 ]
机构
[1] Univ Basel, UZB Univ Ctr Dent Med Basel, Dept Reconstruct Dent, CH-4058 Basel, Switzerland
关键词
fixed prosthodontics; full crown; tooth preparation; intraoral optical scanning (IOS); digital dentistry; PATIENT;
D O I
10.3390/jcm9123984
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(1) Background: Intraoral optical scanning (IOS) has gained increased importance in prosthodontics. The aim of this in vitro study was to analyze the IOS accuracy for treatment with full crowns, considering possible influencing factors. (2) Methods: Two tooth morphologies, each with four different finish-line designs for tooth preparation and epi- or supragingival locations, were digitally designed, 3D-printed, and post-processed for 16 sample abutment teeth. Specimens were digitized using a laboratory scanner to generate reference STLs (Standard Tessellation Language), and were secondary-scanned with two IOS systems five times each in a complete-arch model scenario (Trios 3 Pod, Primescan AC). For accuracy, a best-fit algorithm (Final Surface) was used to analyze deviations of the abutment teeth based on 160 IOS-STLs compared to the reference STLs (16 preparations x 2 IOS-systems x 5 scans per tooth). (3) Results: Analysis revealed homogenous findings with high accuracy for intra- and inter-group comparisons for both IOS systems, with mean values of 80% quantiles from 20 +/- 2 mu m to 50 +/- 5 mu m. Supragingival finishing lines demonstrated significantly higher accuracy than epigingival margins when comparing each preparation (p < 0.05), whereas tangential preparations exhibited similar results independent of the gingival location. Morphology of anterior versus posterior teeth showed slightly better results in favor of molars in combination with shoulder preparations only. (4) Conclusion: The clinical challenge for the treatment with full crowns following digital impressions is the location of the prospective restoration margin related to the distance to the gingiva. However, the overall accuracy for all abutment teeth was very high; thus, the factors tested are unlikely to have a strong clinical impact.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 31 条
[11]   Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner [J].
Fluegge, Tabea V. ;
Schlager, Stefan ;
Nelson, Katja ;
Nahles, Susanne ;
Metzger, Marc C. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (03) :471-478
[12]  
Gintaute Aiste, 2020, Swiss Dent J, V130, P229
[13]  
Goodacre C.J., 2004, Dental Clinics of North America, V48, P359, DOI DOI 10.1016/J.CDEN.2003.12.015
[14]   The complete digital workflow in fixed prosthodontics: a systematic review [J].
Joda, Tim ;
Zarone, Fernando ;
Ferrari, Marco .
BMC ORAL HEALTH, 2017, 17
[15]   Time efficiency, difficulty, and operator's preference comparing digital and conventional implant impressions: a randomized controlled trial [J].
Joda, Tim ;
Lenherr, Patrik ;
Dedem, Philipp ;
Kovaltschuk, Irina ;
Bragger, Urs ;
Zitzmann, Nicola U. .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (10) :1318-1323
[16]   Digital technology in fixed implant prosthodontics [J].
Joda, Tim ;
Ferrari, Marco ;
Gallucci, German O. ;
Wittneben, Julia-Gabriela ;
Bragger, Urs .
PERIODONTOLOGY 2000, 2017, 73 (01) :178-192
[17]   The virtual patient in dental medicine [J].
Joda, Tim ;
Gallucci, German O. .
CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (06) :725-726
[18]   Confounding factors affecting the marginal quality of an intra-oral scan [J].
Keeling, Andrew ;
Wu, Jinhua ;
Ferrari, Marco .
JOURNAL OF DENTISTRY, 2017, 59 :33-40
[19]   A clinical comparison of digital and conventional impression techniques regarding finish line locations and impression time [J].
Koulivand, Soudabeh ;
Ghodsi, Safoura ;
Siadat, Hakimeh ;
Alikhasi, Marzieh .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (02) :236-243
[20]   Mandibular Flexure and Its Significance on Implant Fixed Prostheses: A Review [J].
Law, Constance ;
Bennani, Vincent ;
Lyons, Karl ;
Swain, Michael .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (03) :219-224