Influence of Preparation Design, Marginal Gingiva Location, and Tooth Morphology on the Accuracy of Digital Impressions for Full-Crown Restorations: An In Vitro Investigation

被引:21
作者
Bernauer, Selina A. [1 ]
Mueller, Johannes
Zitzmann, Nicola U. [1 ]
Joda, Tim [1 ]
机构
[1] Univ Basel, UZB Univ Ctr Dent Med Basel, Dept Reconstruct Dent, CH-4058 Basel, Switzerland
关键词
fixed prosthodontics; full crown; tooth preparation; intraoral optical scanning (IOS); digital dentistry; PATIENT;
D O I
10.3390/jcm9123984
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(1) Background: Intraoral optical scanning (IOS) has gained increased importance in prosthodontics. The aim of this in vitro study was to analyze the IOS accuracy for treatment with full crowns, considering possible influencing factors. (2) Methods: Two tooth morphologies, each with four different finish-line designs for tooth preparation and epi- or supragingival locations, were digitally designed, 3D-printed, and post-processed for 16 sample abutment teeth. Specimens were digitized using a laboratory scanner to generate reference STLs (Standard Tessellation Language), and were secondary-scanned with two IOS systems five times each in a complete-arch model scenario (Trios 3 Pod, Primescan AC). For accuracy, a best-fit algorithm (Final Surface) was used to analyze deviations of the abutment teeth based on 160 IOS-STLs compared to the reference STLs (16 preparations x 2 IOS-systems x 5 scans per tooth). (3) Results: Analysis revealed homogenous findings with high accuracy for intra- and inter-group comparisons for both IOS systems, with mean values of 80% quantiles from 20 +/- 2 mu m to 50 +/- 5 mu m. Supragingival finishing lines demonstrated significantly higher accuracy than epigingival margins when comparing each preparation (p < 0.05), whereas tangential preparations exhibited similar results independent of the gingival location. Morphology of anterior versus posterior teeth showed slightly better results in favor of molars in combination with shoulder preparations only. (4) Conclusion: The clinical challenge for the treatment with full crowns following digital impressions is the location of the prospective restoration margin related to the distance to the gingiva. However, the overall accuracy for all abutment teeth was very high; thus, the factors tested are unlikely to have a strong clinical impact.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 31 条
[1]   Fit oftooth-supportedzirconia single crowns-A systematic review of the literature [J].
Ahmed, Walaa Magdy ;
Shariati, Batoul ;
Gazzaz, Arwa Z. ;
Sayed, Mohammed E. ;
Carvalho, Ricardo M. .
CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2020, 6 (06) :700-716
[2]  
Al-Ahmad Adel, 2006, J Prosthodont, V15, P95, DOI 10.1111/j.1532-849X.2006.00081.x
[3]   Influence of Preparation Type and Tooth Geometry on the Accuracy of Different Intraoral Scanners [J].
Ashraf, Yasmine ;
Sabet, Ahmed ;
Hamdy, Amina ;
Ebeid, Kamal .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (09) :800-804
[5]  
Baroudi Kusai, 2015, J Int Oral Health, V7, P96
[6]   Contributing factors of mandibular deformation during mouth opening [J].
Chen, DC ;
Lai, YL ;
Chi, LY ;
Lee, SY .
JOURNAL OF DENTISTRY, 2000, 28 (08) :583-588
[7]   Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters [J].
Chiu, Asher ;
Chen, Yen-Wei ;
Hayashi, Juri ;
Sadr, Alireza .
SENSORS, 2020, 20 (04)
[8]   Impressions are changing Deciding on conventional, digital or digital plus in-office milling [J].
Christensen, Gordon J. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2009, 140 (10) :1301-1304
[9]   A vision of dental education in the third millennium [J].
Eaton, K. A. ;
Reynolds, P. A. ;
Grayden, S. K. ;
Wilson, N. H. F. .
BRITISH DENTAL JOURNAL, 2008, 205 (05) :261-271
[10]  
Ferrari M, 2018, AM J DENT, V31, P272