New method for the photo-chemiluminometric determination of benzoylurea insecticides based on acetonitrile chemiluminescence

被引:28
作者
Garcia, M. D. Gil [1 ]
Galera, M. Martinez [1 ]
Valverde, R. Santiago [1 ]
机构
[1] Univ Almeria, Fac Expt Sci, Dept Analyt Chem, Almeria 04061, Spain
关键词
chemiluminescence detection; photochemical derivatization; HPLC; acetonitrile; vegetables;
D O I
10.1007/s00216-006-0896-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The viability of tandem photochemical reaction-chemiluminescence detection has been studied for the determination of five benzoylurea insecticides, namely, diflubenzuron, triflumuron, hexaflumuron, lufenuron and flufenoxuron. The 'on-line' photochemical reaction of benzoylurea pesticides provides an enhanced chemiluminescence response of the pesticides during their oxidation by potassium hexacyanoferrate(III) and sodium hydroxide, whose signal increases with the percentage of acetonitrile in the reaction medium. The determination was performed using a photoreactor consisting of a PFA (perfluoroalkoxy) tube reactor coil (5 m x 1.6-mm O.D. and 0.8-mm I.D.) and an 8-W xenon lamp. As the yield of the photoderivatization process and the chemiluminescent signals depend on the percentage of acetonitrile, the chromatographic column (a Gemini C18, Phenomenex 150 mm x 4.6 mm, 5-mu m particle size) was chosen with the aim of using high percentages of this organic solvent in the mobile phase. Previous studies showed that the rate of the chemiluminescent reaction was very fast. Therefore, a modification was carried out in the detector in order to mix the analytes and reactants as near as possible to the measure cell. The optimised method was validated with respect to linearity, precision, limits of detection and quantification accuracy. Under the optimised conditions, linear working range extends three orders of magnitude with the relative standard deviation of intra-day precision below 10% and detection limits between 0.012 and 0.18 mu g mL(-1), according to the compound. The proposed method has been successfully applied to the determination of benzoylureas in cucumber with good results.
引用
收藏
页码:1973 / 1981
页数:9
相关论文
共 55 条
[1]   Multiresidue determination of pesticides in plants by high-performance liquid chromatography following gel permeation chromatographic clean-up [J].
Balinova, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :11-16
[2]  
Barnes KA, 1997, RAPID COMMUN MASS SP, V11, P117, DOI 10.1002/(SICI)1097-0231(19970115)11:1<117::AID-RCM781>3.0.CO
[3]  
2-V
[4]   DETERMINATION OF THE PESTICIDES DIFLUBENZURON AND CLOFENTEZINE IN PLUMS, STRAWBERRIES AND BLACK-CURRANT-BASED FRUIT DRINKS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ATMOSPHERIC-PRESSURE CHEMICAL-IONIZATION MASS-SPECTROMETRY [J].
BARNES, KA ;
FUSSELL, RJ ;
STARTIN, JR ;
THORPE, SA ;
REYNOLDS, SL .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (14) :1441-1445
[5]   SFC-UV determination of diflubenzuron residues, teflubenzuron and triflumuron in apple and pear pulps for baby food [J].
Bicchi, C ;
Balbo, C ;
DAmato, A ;
Panero, O .
CHROMATOGRAPHIA, 1996, 43 (7-8) :439-443
[6]   HPLC-UV determination of pesticide residues at 0.01 ppm in apple and pear pulp used for baby food [J].
Bicchi, C ;
Balbo, C ;
Binello, A ;
DAmato, A .
HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1996, 19 (02) :105-110
[7]  
BIRKS JW, 1989, CHEMILUMINESCENCE PH
[8]  
*BRIT CROP PROT CO, 1994, PEST MAN
[9]   Determination of pesticide residues in coconut water by liquid-liquid extraction and gas chromatography with electron-capture plus thermionic specific detection and solid-phase extraction and high-performance liquid chromatography with ultraviolet detection [J].
Brito, NM ;
Navickiene, S ;
Polese, L ;
Jardim, EFG ;
Abakerli, RB ;
Ribeiro, ML .
JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) :201-209
[10]  
CALOKERINOS AC, 2001, CHEMILUMINESCENCE AN, P321